1.2. Connecting External Sensor Input/Relay Output
• Connecting External Sensor Input (16 Channels)
☞ Connect one of two strands of signal lines for various sensors (Infrared sensor,
Heat Wire Detector, Magnetic) to a Signal ( S1 ~ S16) terminal. Connect the other
line to Ground ( GND) terminal.
(Specify sensor "NC, NO" type setting on "Sensor Setting".)
• Connecting External Sensor Relay Output (4 Channels)
☞ Factory setting for control output access point is "NC".
☞ For controlled output, access point is output if it is applied when its type is "No."
• Wiring Diagrams for External Sensor Input / Relay Output
DVR
Wiring Diagram for
Sensor Input
!
Caution 14. Notes on Using a Separate Power Supply for Sensor Input / Relay Output
Use an adapter for sensor input power with an operating voltage less than 12V, 300mA.
Use an adapter for relay output power with an operating voltage less than 12V, 300mA.
Sensor
Sensor
Input
10K
Input
GND +12V
Common
Power
Supply
DVR
Relay
Output
Output
Common
Wiring Diagram for
Sensor Relay Output
68
Power
Supply
+12V
GND