12. Angular Velocity Sensor Sensitivity Adjustment
(CCD-TR640E/TR730E/TR840E/TR845E)
• This adjustment is performed only when replacing the angular
velocity sensor.
Although this adjustment need not be performed when the circuit
is damaged, etc., check the operations.
• Note down the sensitivity displayed on the angular velocity sensor
of the repair parts. At this time, note down also to which board it
was attached to.
Be sure to check because if attached incorrectly, the screen will
vibrate up and down or left and right during hand-shake correction
operations.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A : ENC03EA or ENC 03JA
Type B : ENC03EB or ENC 03JB
Replace the broken sensor with a same type sensor. If replace with
other parts, the image will vibrate up and down or left and right
during hand-shake correction operations. After replacing, re-adjust
according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Adjustment page
F
Adjustment Address
43, 44
Note:
The sensor sensitivity of SE451 and SE452 of the SE-65
board is written only on the repair parts.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Read the sensor sensitivity written on SE451 of the SE-65 board,
and take this as S
.
451
3) Read the sensor sensitivity written on SE452 of the SE-65 board,
and take this as S
.
452
4) Calculate D
' and D
' using the following equation (decimal
43
44
calculation).
D
' = 118 / S
43
451
D
' = 106 / S
44
452
5) Convert D
' and D
' into hexadecimal digits, to obtain D
43
44
D
. (Round off decimal points)
44
6) Select page: F, address: 43, set data: D
button of the adjusting remote commander.
7) Select page: F, address: 44, set data: D
button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: 0, address: 01, and set data: 00.
2) Check that the steady shot operations have been performed
normally.
and
43
, and press the PAUSE
43
, and press the PAUSE
44
5-21