118 en | Appendix
8.8
Communication with Terminal Program
8.8.1
Data Terminal
If a VideoJet X10 cannot be found in the network or the connection to the network is
interrupted, you can connect a data terminal to the VideoJet X10 for initial setup and setting
of important parameters. The data terminal consists of a computer with a terminal program.
You require a serial transmission cable with a 9-pin Sub-D plug to connect to the computer
and open ends for connection to the terminal block of the VideoJet X10 (see Section 8.7.1 Pin
Assignment, page 117).
HyperTerminal, a communications accessory included with Microsoft Windows, can be used
as the terminal program.
NOTICE!
i
Information on installing and using HyperTerminal can be found in the manuals or in the online
help for MS Windows.
1.
2.
8.8.2
Configuring the Terminal
Before the terminal program can communicate with the VideoJet X10, the transmission
parameters must be matched. Make the following settings for the terminal program:
–
–
–
–
–
8.8.3
Command Inputs
After the connection has been established, you must log onto the VideoJet X10 to access the
main menu. Other submenus and functions can be accessed using the on-screen commands.
1.
2.
3.
V3.0 | 2007.09
Disconnect the VideoJet X10 from the Ethernet network before working with the terminal
program.
Connect the serial interface of the VideoJet X10 using any available serial interface on the
computer.
19,200 bps
8 data bits
No parity check
1 stop bit
No protocol
If necessary, turn off the local echo so that entered values are not repeated on the
display.
Enter one command at a time.
When you have entered a value (such as an IP address), check the characters you have
entered before pressing the [ENTER] key to transfer the values to the VideoJet X10.
Installation and Operating Manual
VideoJet X10
Bosch Security Systems