Chapter 38
Power Management and Environmental Monitoring
Table 38-2 Environmental Monitoring for Supervisor Engine and Switching Modules
Component
Supervisor engine temperature sensor
1
exceeds major threshold
Supervisor engine temperature sensor
exceeds minor threshold
Redundant supervisor engine
temperature sensor exceeds major or
minor threshold
Switching module temperature sensor
exceeds major threshold
Switching module temperature sensor
exceeds minor threshold
1. Temperature sensors monitor key supervisor engine components including daughter cards.
2. A STATUS LED is located on the supervisor engine front panel and all module front panels.
3. The STATUS LED is red on the failed supervisor engine. If there is no redundant supervisor, the SYSTEM LED is red also.
4. See the
"Understanding How Power Management Works" section on page 38-1
78-14099-04
Alarm
Type
LED Indication
2
Major
STATUS
LED red
Minor
STATUS LED
orange
Major
STATUS LED red
Minor
STATUS LED
orange
Major
STATUS LED red
Minor
STATUS LED
orange
Catalyst 6500 Series Switch Cisco IOS Software Configuration Guide—Release 12.1 E
Understanding How Environmental Monitoring Works
Action
3
Syslog message and SNMP trap generated.
If redundancy, system switches to redundant
supervisor engine and the active supervisor engine
shuts down.
If there is no redundancy and the overtemperature
condition is not corrected, the system shuts down
after 5 minutes.
Syslog message and SNMP trap generated.
Monitor the condition.
Syslog message and SNMP trap generated.
If major alarm and the overtemperature condition is
not corrected, the system shuts down after 5 minutes.
If minor alarm, monitor the condition.
Syslog message and SNMP trap generated.
Power down the module
Syslog message and SNMP trap generated.
Monitor the condition.
for instructions.
4
.
38-5