Connecting and Powering On the Cisco SNS-3415/3495 Appliance
Slide the server out the front of the rack far enough so that you can remove the top cover. You might have
Step 3
to detach cables from the rear panel to provide clearance.
If you cannot safely view and access the component, remove the server from the rack.
Caution
Remove the top cover as described in Removing and Replacing the Server Top Cover.
Step 4
Move the shorting jumper to pins 2 and 3 of the J37 header (see Figure 2-5).
Step 5
Reinstall the top cover and reconnect AC power cords to the server. The server powers up to standby
Step 6
power mode, indicated when the Power LED on the front panel is amber.
Return the server to main power mode by pressing the Power button on the front panel. The server is in
Step 7
main power mode when the Power LED is green.
Note
Press the Power button to shut down the server to standby power mode, and then remove AC power cords
Step 8
from the server to remove all power.
Remove the top cover from the server.
Step 9
Move the shorting jumper from header pins 2 and 3, back to its default position on pins 1 and 2.
Step 10
Note
Replace the top cover, replace the server in the rack, replace power cords and any other cables, then
Step 11
power on the server by pressing the Power button.
Installation and Upgrade Guide for Cisco Secure Access Control System 5.6
8-18
You must allow the entire server, not just the service processor, to reboot to main power mode
to complete the reset. This is because the state of the jumper cannot be determined without the
host CPU running.
If you do not move the jumper, the CMOS settings are reset to the default every time that you
power-cycle the server.
Chapter 8