hit counter script

Mechanism Deck Service Position - Sony DCR-TRV380 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-TRV380:
Table of Contents

Advertisement

2-2. MECHANISM DECK SERVICE POSITION

1
2
1
5
9
4
4
3
6
3
2
1
6
1
5
4
9
8
5
6
1
7
2
4
3
DCR-TRV380/TRV480/TRV480E
2
6
7
1
8
2
3
7
8
6
5
4
3
4
6
2
5
2-3
Connection to Check the Mechanism deck
To check the mechanism deck, set the Camera or VTR to the "Forced power ON" mode. (Or, connect the control key
block (SS-5100) to the CN1009 of VC-345 board and set the power switch to the "CAMERA" or "PLAY/EDIT" mode.)
Operate the Camera functions of the zoom and focus, the VTR function using the adjustment remote commander
(with the HOLD switch set in the OFF position).
Setting the "Forced Camera Power ON" mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, address: 10, set data: 01 and
press the PAUSE button of the adjustment remote
commander.
Setting the "Forced VTR Power ON" mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, address: 10, set data: 02 and
press the PAUSE button of the adjustment remote
commander.
How to move up the cassette
compartment manually
Press the cassette compartment
in the direction of the arrow
to move it up in the direction of
the arrow B.
1
1
Front panel block
4
Cabinet R block
1
Exiting the "Forced Power ON" mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, address: 10, data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
B
A
A
Lens block
VC-345 board
EVF block/
Battery panel block assembly
AC adaptor
AC IN
When exiting the "Forced Power ON" mode, connect the control
key block (SS-5100) to the CN1009 of VC-345 board. Or, when
ejecting the cassette, connect the control key block (SS-5100) to
the CN1009 of VC-345 board. and press the Eject switch.
2-4
Mechanism deck
Info lithium battery
(L series)
CPC jig connector
(J-6082-539-A)
Contacting
surface
Adjustment remote
commander (RM-95)
I/F unit for LANC control
(J-6082-521-A)
Eject switch
Control key block
(SS-5100)

Advertisement

Table of Contents