Sign In
Upload
Manuals
Brands
Mitsubishi Electric Manuals
Servo Drives
MR-J4-350GF
Mitsubishi Electric MR-J4-350GF Manuals
Manuals and User Guides for Mitsubishi Electric MR-J4-350GF. We have
1
Mitsubishi Electric MR-J4-350GF manual available for free PDF download: Instruction Manual
Mitsubishi Electric MR-J4-350GF Instruction Manual (646 pages)
CC-Link IE Field Network Interface Servo Amplifier Instruction Manual (Motion Mode)
Brand:
Mitsubishi Electric
| Category:
Servo Drives
| Size: 60.47 MB
Table of Contents
Safety Precautions
3
Disposal of Waste
10
About the Manuals
11
Table of Contents
12
Chapter 1 Functions and Configuration
20
Function Block Diagram
21
Servo Amplifier Standard Specifications
32
Combinations of Servo Amplifiers and Servo Motors
38
Function List
40
Model Designation
43
Structure
44
Removal and Reinstallation of the Front Cover
59
Configuration Including Peripheral Equipment
61
Chapter 2 Installation
78
Installation Direction and Clearances
79
Keeping out of Foreign Materials
81
Parts Having Service Life
82
Level
83
Chapter 3 Signals and Wiring
84
Connection Example of Power Circuit
85
I/O Signal Connection Example
97
For Source I/O Interface
99
Explanation of Power Supply System
100
Power-On Sequence
102
Wiring CNP1, CNP2, and CNP3
103
Connectors and Pin Assignment
106
Signal (Device) Explanations
107
Output Device
109
Output Signal
110
Forced Stop Deceleration Function
111
Base Circuit Shut-Off Delay Time Function
113
Vertical Axis Freefall Prevention Function
114
Alarm Occurrence Timing Chart
115
When You Do Not Use the Forced Stop Deceleration Function
116
Interfaces
117
Detailed Explanation of Interfaces
118
Source I/O Interface
120
Servo Motor with an Electromagnetic Brake
121
Timing Chart
122
Grounding
128
Chapter 4 Startup
129
Wiring Check
130
Surrounding Environment
132
Settings of GX Works
133
Startup
134
Switch Setting and Display of the Servo Amplifier
136
Scrolling Display
137
Status Display of a Station
138
CC-Link IE Field Status Display LED
139
Test Operation
140
Test Operation Mode
141
Motor-Less Operation in Controller
144
Home Position Return Mode
145
Cia 402-Type Homing Method
149
Operation Example of Manufacturer-Specific Homing Method
161
Chapter 5 Parameters
170
Basic Setting Parameters ([Pr. PA_ _ ])
171
Gain/Filter Setting Parameters ([Pr. PB_ _ ])
172
Extension Setting Parameters ([Pr. PC_ _ ])
174
I/O Setting Parameters ([Pr. PD_ _ ])
176
Extension Setting 2 Parameters ([Pr. PE_ _ ])
177
Extension Setting 3 Parameters ([Pr. PF_ _ ])
179
Linear Servo Motor/DD Motor Setting Parameters ([Pr. PL_ _ ])
181
Positioning Control Parameters ([Pr. PT_ _ ])
182
Network Setting Parameters ([Pr. PN_ _])
184
Detailed List of Parameters
185
Gain/Filter Setting Parameters ([Pr. PB_ _ ])
194
Extension Setting Parameters ([Pr. PC_ _ ])
204
I/O Setting Parameters ([Pr. PD_ _ ])
211
Extension Setting 2 Parameters ([Pr. PE_ _ ])
214
Extension Setting 3 Parameters ([Pr. PF_ _ ])
217
Linear Servo Motor/DD Motor Setting Parameters ([Pr. PL_ _ ])
220
Positioning Control Parameters ([Pr. PT_ _ ])
223
Network Setting Parameters ([Pr. PN_ _ ])
227
Software Limit
228
Chapter 6 Normal Gain Adjustment
229
Adjustment Using MR Configurator2
230
One-Touch Tuning
231
One-Touch Tuning Flowchart
232
Display Transition and Operation Procedure of One-Touch Tuning
233
Caution for One-Touch Tuning
236
One-Touch Tuning Via a Network
237
Auto Tuning
239
Auto Tuning Mode Basis
240
Adjustment Procedure by Auto Tuning
241
Response Level Setting in Auto Tuning Mode
242
Manual Mode
244
Gain Adjustment Mode
247
Chapter 7 Special Adjustment Functions
249
Adaptive Filter II
252
Shaft Resonance Suppression Filter
254
Low-Pass Filter
255
Advanced Vibration Suppression Control II
256
Command Notch Filter
259
Gain Switching Function
261
Function Block Diagram
262
Parameter
263
Gain Switching Procedure
266
Tough Drive Function
269
Instantaneous Power Failure Tough Drive Function
271
Compliance with SEMI-F47 Standard
275
Model Adaptive Control Disabled
277
Lost Motion Compensation Function
278
Super Trace Control
281
Chapter 8 Troubleshooting
282
Alarm List
283
Warning List
291
Troubleshooting at Power on
293
Chapter 9 Dimensions
294
Servo Amplifier
295
Connector
311
Chapter 10 Characteristics
313
Power Supply Capacity and Generated Loss
317
Dynamic Brake Characteristics
320
Permissible Load to Motor Inertia When the Dynamic Brake Is Used
324
Cable Bending Life
326
Inrush Currents at Power-On of Main Circuit and Control Circuit
327
Chapter 11 Options and Peripheral Equipment
329
Combinations of Cable/Connector Sets
330
MR-D05UDL3M-B STO Cable
334
Battery Cable/Junction Battery Cable
335
Ethernet Cable
336
Regenerative Options
337
Selection of the Regenerative Option
339
Parameter Setting
343
Dimensions
348
FR-BU2-(H) Brake Unit
355
Brake Unit Parameter Setting
356
Connection Example
357
Dimensions
365
FR-RC-(H) Power Regeneration Converter
368
FR-CV-(H) Power Regeneration Common Converter
372
Selection
373
Junction Terminal Block PS7DW-20V14B-F (Recommended)
381
MR Configurator2
383
System Requirements
384
Precautions for Using USB Communication Function
385
Battery
386
MR-BAT6V1SET-A Battery
387
MR-BAT6V1BJ Battery for Junction Battery Cable
391
MR-BT6VCASE Battery Case
395
MR-BAT6V1 Battery
401
Selection Example of Wires
402
Molded-Case Circuit Breakers, Fuses, Magnetic Contactors
406
Power Factor Improving DC Reactors
409
Power Factor Improving AC Reactors
414
Relay (Recommended)
418
Earth-Leakage Current Breaker
427
EMC Filter (Recommended)
430
External Dynamic Brake
437
Panel through Attachment (MR-J4ACN15K/MR-J3ACN)
444
Chapter 12 Absolute Position Detection System
449
Structure
450
Confirmation of Absolute Position Detection Data
451
Battery
452
Using MR-BAT6V1BJ Battery for Junction Battery Cable
453
Using MR-BT6VCASE Battery Case
454
Chapter 13 Using Sto Function
455
Residual Risks of the STO Function
456
Maintenance
457
STO I/O Signal Connector (CN8) and Pin Assignment
458
How to Pull out the STO Cable
459
Connection Example
460
External I/O Signal Connection Example Using an MR-J3-D05 Safety Logic Unit
461
External I/O Signal Connection Example Using an External Safety Relay Unit
464
Detailed Explanation of Interfaces
465
Source I/O Interface
466
Chapter 14 Using a Linear Servo Motor
467
Configuration Including Peripheral Equipment
468
Signals and Wiring
472
Operation and Functions
473
Magnetic Pole Detection
475
Home Position Return
483
Test Operation Mode in MR Configurator2
486
Operation from Controller
488
Absolute Position Detection System
490
Characteristics
491
Power Supply Capacity and Generated Loss
492
Dynamic Brake Characteristics
493
Permissible Load to Motor Mass Ratio When the Dynamic Brake Is Used
494
Chapter 15 Using a Direct Drive Motor
495
Configuration Including Peripheral Equipment
496
Signals and Wiring
498
Operation and Functions
500
Magnetic Pole Detection
501
Operation from Controller
507
Function
508
Characteristics
510
Power Supply Capacity and Generated Loss
511
Chapter 16 Fully Closed Loop System
515
Selecting Procedure of Control Mode
516
System Configuration
518
Load-Side Encoder
520
MR-J4FCCBL03M Branch Cable
522
Operation and Functions
523
Home Position Return
530
Operation from Controller
531
Fully Closed Loop Control Error Detection Functions
532
Auto Tuning Function
533
Absolute Position Detection System under Fully Closed Loop System
534
About MR Configurator2
535
Chapter 17 Application of Functions
537
Scale Measurement Encoder
540
How to Use Scale Measurement Function
543
Controller Setting of the Scale Measurement Function
545
Touch Probe
546
Backup/Restoration Function
550
Parameter Object
551
Enabling Parameters
552
Machine Diagnosis Function
553
Friction Vibration Estimation Function
556
Failure Prediction Function
558
Appendices
565
Appendix 1 When Using the Servo Amplifier with the DC Power Supply Input
568
Power Supply Capacity
568
Molded-Case Circuit Breakers, Fuses, Magnetic Contactors
569
Of Dangerous Goods
571
Appendix 2 Handling of AC Servo Amplifier Batteries for the United Nations Recommendations on the Transport
573
Appendix 3 Symbol for the New EU Battery Directive
573
Appendix 4 Compliance with Global Standards
574
Installation Direction and Clearances
580
Signal
582
Maintenance and Service
583
Transportation and Storage
584
Technical Data
585
Check List for User Documentation
587
Appendix 5 MR-J3-D05 Safety Logic Unit
588
Cautions
589
Block Diagram and Timing Chart
590
Functions and Configuration
591
Signal
594
LED Display
600
Rotary Switch Setting
601
Dimensions
602
Installation
603
Appendix 6 EC Declaration of Conformity
604
Appendix 7 How to Replace Servo Amplifier Without Magnetic Pole Detection
606
Appendix 8 Two-Wire Type Encoder Cable for HG-MR/HG-KR
608
Internal Wiring Diagram
609
Appendix 9 Analog Monitor
610
Details of the Setting
611
Analog Monitor Block Diagram
615
Maximum Current Command (Maximum Torque) for Analog Monitor ±8 V
616
Appendix 10Special Specification
623
Without Regenerative Resistor
624
Special Coating-Specification Product (IEC 60721-3-3 Class 3C2)
625
Appendix 11 Driving On/Off of Main Circuit Power Supply with DC Power Supply
627
Magnetic Contactor
628
Appendix 12List of Registration Objects
629
Servo Transient Transmission Function
631
Appendix 13Status of General-Purpose AC Servo Products for Compliance with the China Rohs Directive
634
Appendix 14Encoder Output Pulse Setting Method
637
Revisions
639
Warranty
643
Trademarks
644
Advertisement
Advertisement
Related Products
Mitsubishi Electric MR-J4-350A(-RJ)
Mitsubishi Electric MR-J4-350A4(-RJ)
Mitsubishi Electric MR-J4-350B(-RJ)
Mitsubishi Electric MR-J4-350B4(-RJ)
Mitsubishi Electric MR-J4-350GF-RJ
Mitsubishi Electric MR-J4-350B-RJ010
Mitsubishi Electric MR-J4-350B4-RJ010
Mitsubishi Electric MELSERVO MR-J4-350B
Mitsubishi Electric MR-J4-200B-RJ010
Mitsubishi Electric MR-J4-10B(-RJ)
Mitsubishi Electric Categories
Air Conditioner
Controller
Projector
Inverter
Heat Pump
More Mitsubishi Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL