Siemens RVL469 Basic Documentation (84 pages)
Heating Controllers
Brand:
Siemens
| Category:
Temperature Controller
| Size: 1.68 MB
Table of Contents
Table of Contents
3
1 Summary
9
RVL470 and RVL469
9
Brief Description and Key Features
9
Type Summary
9
Equipment Combinations
9
Suitable Sensors
9
Suitable Room Units
10
Suitable Actuators
10
Communication
10
Documentation
10
2 Use
11
Types of Plant
11
Types of Buildings
11
Types of Heating Systems
11
Functions
11
3 Fundamentals
13
Key Technical Features
13
Plant Types with Regard to the Heating Circuit
13
Function Blocks
13
Plant Types
13
Plant Type 1 - "Space Heating with a Mixing Valve
13
Plant Type 2 - "Space Heating with a Boiler
14
Plant Type 3 - "Space Heating with District Heat
14
Plant Type 4 - "Pre-Control with a Mixing Valve
14
Plant Type 5 - "Pre-Control with a Boiler
15
Plant Type 6 - "Pre-Control with District Heat
15
Plant Types and Function Blocks
15
Operating Modes
16
Automatic Mode
16
Continuous REDUCED Heating
16
Continuous NORMAL Heating
16
Standby
16
Manual Operation
16
Plant Type and Operating Mode
17
Operational Status and Operational Level
17
4 Acquisition of Measured Values
18
Room Temperature (A6, B5)
18
Measurement
18
Handling of Faults
18
Room Model
18
Flow and Boiler Temperature (B1)
18
Handling of Faults
19
Outside Temperature (B9)
19
Measurement
19
Primary Return Temperature (B7)
19
Secondary Return Temperature (B71)
20
Measurement
20
Handling of Faults
20
5 Function Block "End-User 1
21
Operating Lines
21
Setpoints
21
General
21
Frost Protection for the Building
21
Heating Program
21
Holiday Program
22
6 Function Block "End-User 2
23
Operating Lines
23
Time of Day and Date
23
Indication of Faults
23
7 Function Block "Plant Type
25
Operating Line
25
General
25
8 Function Block "Space Heating
26
Operating Lines
26
ECO Function
26
Compensating Variables and Auxiliary Variables
26
Heating Limits
27
Mode of Operation
27
Switching the Heating off
27
Switching the Heating on
28
Operating Modes and Operational Statuses
28
Room Temperature Source
28
Optimization
28
Definition and Purpose
28
Fundamentals
29
With a Room Temperature Sensor
29
Without a Room Temperature Sensor
29
Process
29
Room Model Temperature
29
Optimum Stop Control
30
Quick Setback
30
Optimum Start Control
31
Boost Heating
31
Room Functions
32
Maximum Limitation of the Room Temperature
32
Room Temperature Influence
33
Heating Curve
33
Purpose
33
Basic Setting
33
Settings with the Bar
34
Settings on Operating Lines
34
Selection of Setting
34
Deflection
34
Parallel Displacement of Heating Curve
35
Display of Setpoints
35
Generation of Setpoint
36
Weather-Compensated Control
36
Demand-Compensated Control
36
9 Function Block "Three-Position Actuator Heating Circuit
37
Operating Lines
37
Limitations
37
Limitations of the Flow Temperature
37
Setpoint Increase
37
Three-Position Control
38
Excess Mixing Valve Temperature
38
Locking of Pulses
38
10 Function Block "Boiler
39
Operating Lines
39
Operating Mode
39
Limitations
39
Maximum Limitation of the Boiler Temperature
39
Minimum Limitation of the Boiler Return Temperature
40
Two-Position Control
40
Control with a Single-Stage Burner
40
Control with a Two-Stage Burner
41
Setting Parameters
41
Control
41
Frost Protection for the Boiler
42
Protective Boiler Startup
42
Protection against Boiler Overtemperatures
43
Operating Mode of Pump M1
44
11 Function Block "Setpoint of Return Temperature Limitation
45
Operating Line
45
Description
45
Minimum Limitation of the Return Temperature
45
Acquisition of the Measured Values
45
Mode of Operation
45
Mode of Operation with a Single Unit (with no Bus)
46
Mode of Operation in Interconnected Plants
46
Central Impact of Limitation
46
Local Impact of Limitation
46
12 Function Block "District Heat
47
Operating Lines
47
Limitations
47
Secondary Flow Temperature
47
Maximum Limitation of Primary Return Temperature
47
Purpose
47
Generation of Maximum Limit Value
47
Function40
48
Maximum Limitation of the Return Temperature Differential (DRT Limitation)
48
Purpose
48
Integral Action Time
49
Minimum Limitation of Stroke (Suppression of Hydraulic Creep)
49
Flow Limitation
49
13 Function Block "Service Functions and General Settings
50
Operating Lines
50
Display Functions
51
Flow Temperature Setpoint
51
Heating Curve
52
Commissioning Aids
52
Simulation of Outside Temperature
52
Relay Test
53
Sensor Test
53
Test of H-Contacts
54
Auxiliary Functions
54
Frost Protection for the Plant
54
Flow Alarm
54
Manual Overriding of Operating Mode (Contact H1)
55
Pump Overrun
55
Pump Kick
56
Winter- / Summertime Changeover
56
Gain of Locking Signal
56
Fundamentals
56
Uncritical Locking Signals
56
Critical Locking Signals
56
Entries for LPB
57
Source of Time of Day
57
Source of Outside Temperature
58
Addressing of Devices
58
Bus Power Supply
59
Bus Loading Characteristic
59
14 Function Block "Contact H2
60
Operating Line
60
Description
60
15 Function Block "External Inputs
61
Operating Lines
61
Contact H2
61
Hours Run Counter
61
Software Version
61
Identification Number of Room Unit
61
Radio Clock, Elapsed Time Since Last Reception
61
16 Function Block "Locking Functions
62
Operating Line
62
Locking the Settings on the Software Side
62
Locking the Settings for District Heat on the Hardware Side
62
17 Communication
63
Combination with Room Units
63
General
63
Combination with Room Unit QAW50
63
Overriding the Operating Mode
63
Setting Knob for Room Temperature Readjustments
63
Combination with Room Unit QAW70
63
Overriding the Operating Mode
64
Setting Knob for Room Temperature Readjustments
64
Effect of the Individual QAW70 Operating Lines on the RVL470
64
Overriding the QAW70 Entries from the RVL470
65
Combination with SYNERGYR Central Unit OZW30
65
Communication with Other Devices
65
18 Rvl469
66
Features and Function
66
Technical Design
66
Type of Plant
66
Operation with a Partner
66
Handling Errors
67
Wrong Addressing
67
Missing or Wrong Partner
67
Passive Mode
67
19 Handling
68
Operation
68
General
68
Operating Elements
68
Display
69
Operating Instructions
69
Analog Operating Elements
69
Buttons and Displays for Selecting the Operating Mode
69
Heating Curve
69
Setting Knob for Room Temperature Readjustments
69
Buttons and Displays for Manual Operation
69
Display of Positioning Commands
70
Display "Heating Operates
70
Digital Operating Elements
70
Operating Line Principle
70
Buttons
70
Block Skip Function
70
Info Button
71
Setting Levels and Access Rights
71
Setting Levels
71
Access Rights
71
Commissioning
71
Installation Instructions
71
Operating Lines
71
Setting the Operating Line "Plant Type
71
Setting the Other Operating Lines
72
Operating Lines for Functional Checks
72
Installation
72
Location
72
Mounting Choices
72
Wiring
72
20 Engineering
73
Connection Terminals
73
Low Voltage Side
73
Mains Voltage Side
73
Connection Diagrams
74
Basic Connections on the Low Voltage Side
74
Basic Connections on the Mains Voltage Side
74
21 Mechanical Design
75
Basic Design
75
Dimensions
75
22 Technical Data
76
Advertisement
Siemens RVL469 Operation Manual (8 pages)
Siemens Building Technologies Heating Controller Operation Manual RVL469
Brand:
Siemens
| Category:
Controller
| Size: 0.46 MB
Table of Contents
Equipment Combinations
2
Technical Design
2
Mechanical Design
4
Technical Data
6
Connection Diagrams
6
Advertisement
Related Products
Siemens RVL470
Siemens RVL482
Siemens RVL481
Siemens RVL480
Siemens RVL479
Siemens RDF400
Siemens REV34
Siemens RCU50.2U
Siemens RDF210
Siemens RDF210.2/IR
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL