Sign In
Upload
Manuals
Brands
Siemens Manuals
Relays
siprotec SJ62
Siemens siprotec SJ62 Protective Relay Manuals
Manuals and User Guides for Siemens siprotec SJ62 Protective Relay. We have
1
Siemens siprotec SJ62 Protective Relay manual available for free PDF download: User Manual
Siemens siprotec SJ62 User Manual (715 pages)
Multi-Functional Protective Relay with Local Control
Brand:
Siemens
| Category:
Relays
| Size: 29.19 MB
Table of Contents
Preface
4
Table of Contents
10
1 Introduction
22
Overall Operation
23
Application Scope
27
Characteristics
30
2 Functions
36
General
38
Functional Scope
38
Description
38
Setting Notes
38
Settings
40
Device, General Settings
43
Description
43
Setting Notes
43
Settings
44
Information List
44
Power System Data 1
46
Description
46
Setting Notes
46
Settings
50
Information List
51
Oscillographic Fault Records
52
Description
52
Setting Notes
52
Settings
53
Information List
53
Settings Groups
54
Description
54
Setting Notes
54
Settings
55
Information List
55
Power System Data 2
56
Description
56
Setting Notes
56
Settings
59
Information List
59
EN100-Module
60
Functional Description
60
Setting Notes
60
Information List
60
Overcurrent Protection 50, 51, 50N, 51N
61
General
61
Definite High-Current Elements 50-2, 50N-2
62
Definite Overcurrent Elements 50-1, 50N-1
65
Inverse Time Overcurrent Elements 51, 51N
68
Dynamic Cold Load Pickup Function
71
Inrush Restraint
71
Pickup Logic and Tripping Logic
74
Two-Phase Time Overcurrent Protection (Non-Directional Only)
75
Busbar Protection by Use of Reverse Interlocking
75
Setting Notes
76
Settings
84
Information List
86
Directional Overcurrent Protection 67, 67N
89
General
89
Definite Time, Directional High-Set Elements 67-2, 67N-2
92
Definite Time, Directional Overcurrent Elements 67-1, 67N-1
94
Inverse Time, Directional Overcurrent Protection Elements 67-TOC, 67N-TOC
96
Interaction with the Fuse Failure Monitor (FFM)
99
Dynamic Cold Load Pickup Function
99
Inrush Restraint
99
Determination of Direction
99
Reverse Interlocking for Double End Fed Lines
104
Setting Notes
105
Settings
115
Information List
117
Dynamic Cold Load Pickup
119
Description
119
Setting Notes
122
Settings
123
Information List
124
Single-Phase Overcurrent Protection
125
Functional Description
125
High-Impedance Ground Fault Unit Protection
127
Tank Leakage Protection
129
Setting Notes
130
Settings
135
Information List
135
Voltage Protection 27, 59
136
Measurement Principle
136
Overvoltage Protection 59
138
Undervoltage Protection 27
139
Setting Notes
143
Settings
146
Information List
147
Negative Sequence Protection 46
148
Definite Time Element 46-1, 46-2
148
Inverse Time Element 46-TOC
149
Setting Notes
152
Settings
155
Information List
155
Motor Protection (Motor Starting Protection 48, Motor Restart Inhibit 66)
156
Motor Starting Protection 48
156
Description
156
Setting Notes
159
Motor Restart Inhibit 66
161
Description
161
Setting Notes
167
Motor (Motor Starting Protection 48, Motor Restart Inhibit 66)
171
Settings
171
Information List
172
Frequency Protection 81 O/U
173
Description
173
Setting Notes
174
Settings
176
Information List
176
Thermal Overload Protection 49
177
Description
177
Setting Notes
181
Settings
186
Information List
186
Monitoring Functions
187
Measurement Supervision
187
General
187
Hardware Monitoring
187
Software Monitoring
188
Monitoring of the Transformer Circuits
188
Measurement Voltage Failure Detection
191
Setting Notes
193
Settings
194
Information List
195
Trip Circuit Supervision 74TC
195
Description
196
Setting Notes
199
Settings
199
Information List
199
Malfunction Responses of the Monitoring Functions
200
Description
200
Ground Fault Protection 64, 67N(S), 50N(S), 51N(S)
202
Voltage Element 64
202
Current Elements 50Ns, 51Ns
203
Determination of Direction
204
Logic
207
Ground Fault Location (in Isolated Systems)
210
Setting Notes
211
Settings
219
Information List
221
Intermittent Ground Fault Protection
222
Description
222
Setting Notes
228
Settings
229
Information List
229
Automatic Reclosing System 79
230
Program Execution
231
Blocking
235
Status Recognition and Monitoring of the Circuit Breaker
237
Controlling Protective Elements
239
Zone Sequencing (Not Available for Models 7SJ6***-**A**-)
241
Setting Notes
242
Settings
249
Information List
254
Fault Locator
256
Description
256
Setting Notes
258
Settings
258
Information List
258
Breaker Failure Protection 50BF
259
Description
259
Setting Notes
261
Settings
263
Information List
263
Flexible Protection Functions (7SJ64 Only)
264
Functional Description
264
Setting Notes
269
Settings
274
Information List
275
Reverse-Power Protection Application with Flexible Protection Function
276
Description
276
Implementation of the Reverse-Power Protection
280
Configuring the Reverse-Power Protection in DIGSI
282
Synchronism and Voltage Check 25 (7SJ64 Only)
285
SYNC Function Group 1
285
General
285
Synchrocheck
288
Synchronous / Asynchronous
289
De-Energized Switching
290
Direct Command / Blocking
291
SYNC Function Groups
291
Interaction with Control, AR and External Control
292
Setting Notes
294
Settings
300
Information List
301
Temperature Detection Via RTD Boxes
303
Description
303
Setting Notes
304
Settings
306
Information List
311
Phase Rotation
312
Description
312
Setting Notes
313
Function Logic
314
Pickup Logic for the Entire Device
314
Tripping Logic of the Entire Device
314
Setting Notes
315
Auxiliary Functions
316
Commissionig Aids with Browser (7SJ64 Only)
316
Functional Description
316
Setting Notes
318
Message Processing
319
LED Display and Binary Outputs (Output Relays)
319
Information on the Integrated Display (LCD) or Personal Computer
320
Information to a Substation Control Center
321
Statistics
322
Description
322
Circuit-Breaker Maintenance
323
Setting Notes
330
Information List
332
Measurement
333
Display of Measured Values
333
Transfer of Measured Values
335
Information List
335
Average Measurements
337
Description
337
Setting Notes
337
Settings
337
Information List
338
Min/Max Measurement Setup
338
Description
338
Setting Notes
338
Settings
339
Information List
339
Set Points for Measured Values
341
Description
341
Setting Notes
342
Information List
342
Set Points for Statistic
343
Description
343
Setting Notes
343
Information List
343
Energy Metering
344
Description
344
Setting Notes
344
Settings
344
Information List
344
Commissioning Aids
345
Description
345
Protection for Single-Phase Voltage Transformer Connection
347
Connection
347
Impacts on the Functionality of the Device
348
Setting Notes
350
Breaker Control
352
Control Device
352
Description
352
Information List
353
Types of Commands
354
Description
354
Command Sequence
355
Description
355
Interlocking
356
Description
356
Command Logging
364
Description
364
3 Mounting and Commissioning
366
Mounting and Connections
367
Configuration Information
367
Hardware Modifications
372
General
372
Disassembly
374
Switching Elements on the Printed Circuit Boards of Device 7SJ62
380
Switching Elements on the Printed Circuit Boards of Device 7SJ63
386
Switching Elements on the Printed Circuit Boards of Device 7SJ64
394
Interface Modules
404
Reassembly
408
Installation
408
Panel Flush Mounting
408
Rack Mounting and Cubicle Mounting
410
Panel Surface Mounting
413
Mounting with Detached Operator Panel
414
Mounting Without Operator Panel
415
Checking Connections
417
Checking Data Connections of Serial Interfaces
417
Checking System Connections
420
Commissioning
422
Test Mode and Transmission Block
423
Checking the System (SCADA) Interface
423
Checking the Status of Binary Inputs and Outputs
425
Tests for Circuit Breaker Failure Protection
428
Checking User-Defined Functions
429
Current, Voltage, and Phase Rotation Testing
429
Test for High Impedance Protection
431
Testing the Reverse Interlocking Scheme
431
Direction Check with Load Current
431
Polarity Check for Voltage Input
433
Only 7SJ64)
433
Ground Fault Check
435
Polarity Check for Current Input I
436
Checking the Temperature Measurement Via RTD-Box
438
Measuring the Operating Time of the Circuit Breaker (Only 7SJ64)
439
Trip/Close Tests for the Configured Operating Devices
440
Creating Oscillographic Recordings for Tests
441
Final Preparation of the Device
442
4 Technical Data
444
General Device Data
446
Analog Inputs
446
Auxiliary Voltage
447
Binary Inputs and Outputs
448
Communication Interfaces
450
Electrical Tests
456
Mechanical Stress Tests
457
Climatic Stress Tests
458
Service Conditions
459
Certifications
459
Design
459
Definite Time Overcurrent Protection 50, 50N
461
Inverse Time Overcurrent Protection 51, 51N
463
Directional Time Overcurrent Protection 67, 67N
475
Inrush Restraint
477
Dynamic Cold Load Pickup Function
478
Single-Phase Overcurrent Protection 50
479
Voltage Protection 27, 59
480
Negative Sequence Protection 46-1, 46-2
482
Negative Sequence Protection 46-TOC
483
Motor Starting Protection 48
489
Motor Restart Inhibit 66
490
Frequency Protection 81 O/U
491
Thermal Overload Protection 49
492
Ground Fault Detection 64, 50Ns, 51Ns, 67Ns
495
Intermittent Ground Fault Protection
499
Automatic Reclosing System 79
500
Fault Location
501
Circuit Breaker Failure Protection 50BF
502
Flexible Protection Functions (7SJ64 Only)
503
Synchronism and Voltage Check 25 (7SJ64 Only)
505
RTD Boxes for Temperature Detection
507
User-Defined Functions (CFC)
508
Additional Functions
513
Breaker Control
519
Dimensions
520
Panel Flush and Cubicle Mounting (Housing Size 1 / 3 )
520
Panel Flush and Cubicle Mounting (Housing Size 1 / 2 )
521
Panel Flush and Cubicle Mounting (Housing Size 1 / 1 )
522
Panel Surface Mounting (Housing Size 1 / 3 )
523
Panel Surface Mounting (Housing Size 1 / 2 )
523
Panel Surface Mounting (Housing Size 1 / 1 )
524
Surface-Mounted Housing with Detached Operator Panel or Without Operator Panel (Housing Size )
525
Housing for Mounting with Detached Operator Panel or Without Operator Panel (Housing Size )
526
Detached Operator Panel
527
D-Subminiature Connector of Dongle Cable (Panel Flush or Cubicle Door Cutout)
528
Appendix
530
Ordering Information and Accessories
531
Ordering Information
531
7Sj62 V4.6
531
7Sj63 V4.6
535
A.1.1.2 7Sj63 V4.6
535
7Sj64 V4.6
539
A.1.1.3 7Sj64 V4.6
539
Accessories
543
A.1.2 Accessories
543
Terminal Assignments
545
7SJ62 - Housing for Panel Flush Mounting or Cubicle Installation
545
A.2 Terminal Assignments
545
7SJ62 - Housing for Panel Surface Mounting
547
7SJ62 - Interface Assignment on Housing for Panel Surface Mounting
549
7SJ63 - Housing for Panel Flush Mounting or Cubicle Installation
551
7SJ631/2/3 - Housing for Panel Surface Mounting
558
7SJ631/2/3 - Interface Assignment on Housing for Panel Surface Mounting
561
7SJ635/6 - Housing for Panel Surface Mounting
563
7SJ635/6 - Interface Assignment on Housing for Panel Surface Mounting
567
7SJ63 - Housing with Detached Operator Panel
569
7SJ63 - Housing for Panel Surface Mounting Without Operator Panel
576
7SJ64 - Housing for Panel Flush Mounting or Cubicle Installation
583
7SJ64 - Housing for Panel Surface Mounting
588
7SJ64 - Housing with Detached Operator Panel
593
7SJ64 - Housing for Panel Surface Mounting Without Operator Panel
597
Connector Assignment
600
A.2.15 Connector Assignment
600
Connection Examples
601
Connection Examples for 7SJ62
601
A.3 Connection Examples
601
Connection Examples for 7SJ63
608
Connection Examples for 7SJ64
617
Connection Example for High-Impedance Ground Fault Differential Protection
627
Connection Examples for RTD-Box
627
Current Transformer Requirements
629
Accuracy Limiting Factors
629
Class Conversion
630
A.4.2 Class Conversion
630
Cable Core Balance Current Transformer
631
Default Settings
632
Leds
632
Binary Input
632
A.5 Default Settings
632
Binary Output
633
A.5.3 Binary Output
633
Function Keys
634
Default Display
634
A.5.4 Function Keys
634
Pre-Defined CFC Charts
639
Protocol-Dependent Functions
642
Functional Scope
643
A.7 Functional Scope
643
Settings
646
A.8 Settings
646
Information List
667
A.9 Information List
667
Group Alarms
694
A.10 Group Alarms
694
Measured Values
695
A.11 Measured Values
695
Literature
700
Glossary
702
Index
710
Advertisement
Advertisement
Related Products
Siemens siprotec SJ63
Siemens siprotec SJ64
Siemens SIPROTEC4 7SJ63
Siemens SIMPRO-100
Siemens SIRIUS 3TK2826- BB41/2/4 Series
Siemens SIRIUS 3TK2826- CW31/2/4 Series
Siemens SIRIUS S10
Siemens SIRIUS S12
Siemens SIP5C
Siemens SIPROTEC4 7UM61
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL