Sign In
Upload
Manuals
Brands
Siemens Manuals
Controller
SIRIUS 3RW30
Siemens SIRIUS 3RW30 Soft Starter Manuals
Manuals and User Guides for Siemens SIRIUS 3RW30 Soft Starter. We have
5
Siemens SIRIUS 3RW30 Soft Starter manuals available for free PDF download: Manual, Operating Instructions Manual, Assembly Instructions Manual, Assembly Instructions
Siemens SIRIUS 3RW30 Manual (212 pages)
Soft starters
Brand:
Siemens
| Category:
Controller
| Size: 14.08 MB
Table of Contents
Table of Contents
5
1 Introduction
11
Important Notes
11
2 Safety Information
13
Before Commencing Work: Isolating the Equipment from the Supply System and Ensuring that It Cannot be Reconnected
13
Five Safety Rules for Work in or on Electrical Systems
13
3 Product Description
15
Fields of Application
15
Basic Physical Principles of a Three-Phase Induction Motor
15
Three-Phase Induction Motor
15
Operation
16
Functional Principle of the SIRIUS 3RW30 and 3RW40 Soft Starters
17
Method of Operation of a Two-Phase Controlled Soft Starter
20
Starting Current Asymmetry
21
Applications and Use
22
Commissioning
22
Comparison of Device Functions
24
4 Product Combinations
25
SIRIUS Modular System
25
Technical Data
25
5 Functions
27
Start Modes
27
Voltage Ramp
27
Current Limiting and Ramp-Up Detection (3RW40 Only)
29
Stop Modes
30
Stop Without Load (3RW30 and 3RW40)
31
Soft Stop (3RW40 Only)
31
Motor Protection / Intrinsic Device Protection (3RW40 Only)
32
Motor Protection Function
32
Intrinsic Device Protection (3RW40 Only)
35
Functions of the RESET Buttons
36
SIRIUS 3RW40 2, 3RW40 3, and 3RW40 4 Soft Starters
36
SIRIUS 3RW40 5 and 3RW40 7 Soft Starters
38
Other Functions of the RESET Button
39
Functions of the Inputs
40
Start Input (Terminal 1) on 3RW30 and 3RW40 2 to 3RW40 4
40
Start Input (Terminal 3) on 3RW40 5 and 3RW40 7
40
Thermistor Input / Connection on 3RW40 2 to 3RW40 4
41
Functions of the Outputs
41
3RW30: Output Terminal 13 / 14 on
41
3RW40: Output Terminals 13 / 14 on / RUN and 23 / 24 BYPASSED
42
3RW40: Group Fault Output at Terminal 95 / 96 / 98 OVERLOAD / FAILURE
43
Diagnostics and Fault Signals
44
3RW30: Leds and Troubleshooting
44
3RW40: Leds and Troubleshooting
46
6 Application Planning
51
Application Examples
51
Roller Conveyor Application
51
Hydraulic Pump Application
52
7 Installation
53
Installing the Soft Starter
53
Unpacking
53
Permissible Mounting Position
53
Mounting Dimensions, Clearances, and Assembly Type
54
Assembly Type: Standalone Assembly, Side-By-Side Assembly, Direct Mounting
55
Installation Requirements
56
8 Installation / Mounting
57
General Information
57
Five Safety Rules for Work in or on Electrical Systems
58
General Feeder Assembly (Type of Coordination 1)
59
Soft Starter with Line Contactor (Type of Coordination 1)
60
Soft Starter Assembly with Type of Coordination 2
61
Capacitors to Improve the Power Factor
62
Maximum Cable Length
63
9 Connecting
65
Electrical Connection
65
Control and Auxiliary Terminals
65
Main Circuit Connection
65
10 Operation
69
Operator Controls, Displays, and Connections on the 3RW30
69
Operator Controls, Displays, and Connections on the 3RW40
70
11 Configuration
73
Configuration in General
73
Configuration Procedure
73
Selecting the Optimum Soft Starter
74
Startup Class
76
Application Examples for Normal Starting (CLASS 10) with 3RW30 and 3RW40
77
Application Examples for Heavy-Duty Starting (CLASS 20): 3RW40 Only
78
ON Time and Switching Frequency
79
Reducing the Rated Data
80
Installation Altitude and Ambient Temperature
80
Calculating the Permissible Switching Frequency
81
Table of Permissible Assembly Combinations with Switching Frequency Factors
81
Calculating the Switching Frequency (Example)
84
Configuration Aids
86
Online Configurator
86
Win-Soft Starter Selection and Simulation Software
86
Technical Assistance
86
SIRIUS Soft Starter Training Course (SD-SIRIUSO)
87
Order Number System for the 3RW30
88
Order Number System for the 3RW40
89
12 Commissioning
91
Before Commencing Work: Isolating the Equipment from the Supply System and Ensuring that It Cannot be Reconnected
91
Commissioning the 3RW30
92
Commissioning Procedure
92
Quick Commissioning of the 3RW30 and Optimization of the Parameters
93
Setting the Soft Start Function
94
Setting the Starting Voltage
95
Setting the Ramp Time
95
ON Output
96
3RW30: Leds and Troubleshooting
97
Commissioning the 3RW40
98
Commissioning Procedure
99
Quick Commissioning of the 3RW40 and Optimization of the Parameters
100
Setting the Soft Start Function
101
Setting the Starting Voltage
102
Setting the Ramp Time
102
Current Limiting in Conjunction with a Starting Voltage Ramp and Ramp-Up Detection
103
Setting the Motor Current
103
Setting the Current Limiting Value
104
Ramp-Up Detection
104
Setting the Soft Stop Function
105
Setting the Ramp-Down Time
105
Setting the Motor Protection Function
105
Setting the Electronic Motor Overload Protection
106
Motor Current Settings
107
Motor Protection Acc. to ATEX
107
Thermistor Motor Protection
108
Motor Protection Trip Test
108
Functions of the Outputs
109
Functions of the BYPASSED and on / RUN Outputs
109
Parameterizing the 3RW40 Outputs
110
Function of the FAILURE / OVERLOAD Output
112
RESET MODE and Functions of the RESET / TEST Button
113
SIRIUS 3RW40 2. to 3RW40 4. Soft Starters
113
SIRIUS 3RW40 5. to 3RW40 7. Soft Starters
115
3RW40: Leds and Troubleshooting
117
13 Technical Data
121
Overview
121
Selection and Ordering Data for Standard Applications and Normal Starting
122
3Rw30
123
3Rw30
124
3Rw30 13, 14, 16, 17, 18-.Bb
124
3Rw30 26, 27, 28-.Bb
125
3Rw30 36, 37, 38, 46, 47-.Bb
125
3RW30 Main Conductor Cross-Sections
126
3RW30 Auxiliary Conductor Cross-Sections
127
Electromagnetic Compatibility According to en 60947-4-2
127
Recommended Filters
128
Types of Coordination
128
Fuseless Version
129
Fused Version (Line Protection Only)
130
Fused Version with SITOR 3NE1 Fuses
131
Fused Version with SITOR 3NE3/4/8 Fuses
132
Overview
134
Rw40
134
Selection and Ordering Data for Standard Applications and Normal Starting (CLASS 10)
135
Selection and Ordering Data for Standard Applications and Normal Starting (CLASS 10) (with Thermistor Motor Protection Evaluation)
137
Selection and Ordering Data for Standard Applications and Normal Starting (CLASS 10)
139
Selection and Ordering Data for Standard Applications and Heavy-Duty Starting (CLASS 20)
141
Selection and Ordering Data for Standard Applications and Heavy-Duty Starting (CLASS 20)
143
3RW40 2., 3., 4. Control Electronics
145
3RW40 5., 7. Control Electronics
145
3RW40 2., 3., 4. Control Electronics
146
3RW40 5., 7. Control Electronics
146
3RW40 Protection Functions
147
3RW40 Control Times and Parameters
147
3RW40 2. to 7. Power Electronics
148
3RW40 24, 26, 27, 28 Power Electronics
149
3RW40 36, 37, 38, 46, 47 Power Electronics
150
3RW40 55, 56, 73, 74, 75, 76 Power Electronics
151
3RW40 2., 3., 4. Main Conductor Cross-Sections
152
3RW40 5., 7. Main Conductor Cross-Sections
153
3Rw40
154
Electromagnetic Compatibility According to en 60947-4-2
154
Recommended Filters
155
Types of Coordination
155
Fuseless Version
156
Fused Version (Line Protection Only)
157
Fused Version with SITOR 3NE1 Fuses
158
Fused Version with SITOR 3NE3/4/8 Fuses
159
Motor Protection Tripping Characteristics for 3RW40 (with Symmetry)
161
Motor Protection Tripping Characteristics for 3RW40 (with Asymmetry)
161
Win-Soft Starter Selection and Simulation Software
162
14 Dimension Drawings
163
3RW30 for Standard Applications
163
3RW40 for Standard Applications
164
15 Typical Circuit Diagrams
167
Typical Circuit for the Optional Thermistor Motor Protection Evaluation
167
Control by Pushbutton
168
Control of the 3RW30 by Pushbutton
168
Control of the 3RW40 by Pushbutton
169
Control by Switch
170
Control of the 3RW30 by Switch
170
Control of the 3RW40 by Switch
171
Control in Automatic Mode
172
Control of the 3RW30 in Automatic Mode
172
Control of the 3RW40 in Automatic Mode
173
Control by PLC
175
Control of the 3RW30 with 24 V DC by PLC
175
Control of the 3RW40 by PLC
176
Control with an Optional Main / Line Contactor
177
Control of the 3RW30 with a Main Contactor
177
Control of the 3RW40 with a Main Contactor
178
Reversing Circuit
180
3RW30 Reversing Circuit
180
3RW40 Reversing Circuit
181
Control of a Magnetic Parking Brake
183
3RW30 Motor with Magnetic Parking Brake
183
3RW40 2 to 3RW40 4, Control of a Motor with a Magnetic Parking Brake
184
3RW40 5 to 3RW40 7, Control of a Motor with a Magnetic Parking Brake
185
Emergency Stop
186
3RW30 Emergency Stop and 3TK2823 Safety Relay
186
3RW40 2 to 3RW40 4 Emergency Stop and 3TK2823 Safety Relay
187
3RW40 5 to 3RW40 7 Emergency Stop and 3TK2823 Safety Relay
189
3RW and Contactor for Emergency Starting
191
3RW30 and Contactor for Emergency Starting
191
3RW40 and Contactor for Emergency Starting
192
Dahlander / Multispeed Motor
194
3RW30 and Dahlander Motor Starting
194
3RW40 2 to 3RW40 4 and Dahlander Motor Starting
195
3RW40 5 to 3RW40 7 and Dahlander Motor Starting
197
16 Accessories
199
Box Terminal Blocks for Soft Starters
199
Auxiliary Conductor Terminals
199
Covers for Soft Starters
199
Modules for RESET
200
Link Modules to 3RV10 Motor Starter Protectors
201
Link Modules to 3RV20 Motor Starter Protectors
201
Optional Fan to Increase the Switching Frequency (3RW40 2. to 3RW40 4.)
202
Spare Parts for Fans (3RW40 5., 3RW40 7.)
202
Operating Instructions
202
Appendix
203
Configuration Data
203
A.1 Configuration Data
203
Table of Parameters Used
205
Correction Sheet
206
A.3 Correction Sheet
206
Advertisement
Siemens SIRIUS 3RW30 Manual (204 pages)
Industrial Controls
Brand:
Siemens
| Category:
Controller
| Size: 24.82 MB
Table of Contents
Table of Contents
3
1 Introduction
9
Important Notes
9
Additional Documentation
11
Siemens Industry Online Support
13
Technical Assistance
15
Siemens Industry Online Support App
15
2 Safety Information
17
ESD Guidelines
17
Reactive Power Compensation
19
Electromagnetic Compatibility (EMC) According to IEC 60947-4-1
19
Security Information
20
Recycling and Disposal
21
Before Commencing Work: Isolating the Equipment from the Supply System and Ensuring that It Cannot be Reconnected
21
Five Safety Rules for Work in or on Electrical Systems
22
3 Product Description
23
Fields of Application
23
Functional Principle of the SIRIUS 3RW30 and 3RW40 Soft Starters
24
Method of Operation of a Two-Phase Controlled Soft Starter
26
Starting Current Asymmetry
28
Applications and Use
29
Comparison of Device Functions
30
Accessories
31
Accessories for 3RW30 Soft Starters
31
Accessories for 3RW40 Soft Starters
32
4 Product Combinations
33
SIRIUS Modular System
33
5 Functions
35
Start Modes
35
Voltage Ramp
35
Current Limiting and Ramp-Up Detection (3RW40 Only)
38
Stop Modes
40
Stop Without Load (3RW30 and 3RW40)
40
Soft Stop (3RW40 Only)
41
Motor Protection / Intrinsic Device Protection (3RW40 Only)
42
Motor Protection Function
42
Intrinsic Device Protection (3RW40 Only)
45
Functions of the RESET Buttons
47
SIRIUS 3RW402, 3RW403 and 3RW404 Soft Starters
47
Setting the RESET MODE
47
Manual RESET
48
Remote RESET
48
Auto RESET
48
Acknowledging Faults
49
SIRIUS 3RW405 and 3RW407 Soft Starters
49
Setting the RESET MODE
49
Manual RESET
49
Auto RESET
50
Acknowledging Faults
50
Other Functions of the RESET Button
50
Motor Protection Trip Test
50
Reparameterizing the on / RUN Output Contact
51
Reset Options for Fault Acknowledgement
51
Functions of the Inputs
52
Start Input (Terminal 1) on 3RW30 and 3RW402 to 3RW404
52
Start Input (Terminal 3) on 3RW405 and 3RW407
53
Thermistor Input / Connection on 3RW402 to 3RW404
53
Functions of the Outputs
54
3RW30: Output Terminal 13 / 14 on
54
3RW40: Output Terminals 13 / 14 on / RUN and 23 / 24 BYPASSED
54
3RW40: Group Fault Output at Terminal 95 / 96 / 98 OVERLOAD / FAILURE
56
6 Messages and Diagnosis
57
3RW30: Leds
57
3RW30: Troubleshooting
58
3RW402 / 3RW403 / 3RW404: Leds
59
3RW405 / 3RW407: Leds
61
3RW40: Troubleshooting
63
7 Application Planning
65
Application Examples
65
Roller Conveyor Application
65
Hydraulic Pump Application
66
8 Installation
67
Installing the Soft Starter
67
Unpacking
67
Permissible Mounting Position
67
Mounting Dimensions, Clearances, and Assembly Type
68
Assembly Type: Standalone Assembly, Side-By-Side Assembly, Direct Mounting
69
Installation Requirements
70
9 Installation / Mounting
71
General Information
71
General Feeder Assembly (Type of Coordination 1)
72
Soft Starter with Line Contactor (Type of Coordination 1)
73
Soft Starter Assembly with Type of Coordination 2
74
Capacitors to Improve the Power Factor
76
Maximum Cable Length
76
10 Connecting
77
Electrical Connection
77
Control and Auxiliary Terminals
77
Main Circuit Connection
77
11 Operation
81
Operator Controls, Displays, and Connections on the 3RW30
81
Operator Controls, Displays, and Connections on the 3RW40
82
Effects on Changing the Potentiometer Settings
84
12 Configuration
85
Configuration in General
85
Configuration Procedure
86
Selecting the Optimum Soft Starter
86
Startup Class
89
Application Examples for Normal Starting (CLASS 10) with 3RW30 and 3RW40
90
Application Examples for Heavy-Duty Starting (CLASS 20): 3RW40 Only
91
ON Time and Switching Frequency
92
Reducing the Rated Data
93
Dimensioning of Soft Starters for Motors with High Starting Current Conditions
93
Installation Altitude and Ambient Temperature
94
Calculating the Permissible Switching Frequency
95
Table of Permissible Assembly Combinations with Switching Frequency Factors
95
Calculating the Switching Frequency (Example)
98
Configuration Aids
100
Selection of the Soft Starter Using the Simulation Tool for Soft Starters
100
Article Number System for the 3RW30
101
Article Number System for the 3RW40
102
13 Commissioning
103
Commissioning the 3RW30
103
Commissioning Procedure
103
Quick Commissioning of the 3RW30 and Optimization of the Parameters
104
Setting the Soft Start Function
105
Setting the Starting Voltage
106
Setting the Ramp Time
106
ON Output
108
Commissioning the 3RW40
109
Commissioning Procedure
109
Quick Commissioning of the 3RW40 and Optimization of the Parameters
110
Setting the Soft Start Function
111
Setting the Starting Voltage
112
Setting the Ramp Time
112
Current Limiting in Conjunction with a Starting Voltage Ramp and Ramp-Up Detection
113
Setting the Motor Current
114
Setting the Current Limiting Value
114
Optimized Setting Ranges for Current Limiting
116
Ramp-Up Detection
117
Setting the Soft Stop Function
118
Setting the Ramp-Down Time
118
Setting the Motor Protection Function
119
Setting the Electronic Motor Overload Protection
119
Motor Current Settings
120
Motor Protection Acc. to ATEX
120
Thermistor Motor Protection
121
Motor Protection Trip Test
121
Functions of the Outputs
122
Functions of the BYPASSED and on / RUN Outputs
122
Parameterizing the 3RW40 Outputs
123
Function of the FAILURE / OVERLOAD Output
125
14 Technical Data
127
Technical Data in Siemens Industry Online Support
127
Overview
128
14.2 3Rw30
128
3Rw30
129
14.2 3Rw30
130
3Rw30 13, 14, 16, 17, 18-.Bb
130
3Rw30 26, 27, 28-.Bb
131
3Rw30 36, 37, 38, 46, 47-.Bb
131
3RW30 Main Conductor Cross-Sections
132
3RW30 Auxiliary Conductor Cross-Sections
133
Electromagnetic Compatibility According to en 60947-4-2
133
Recommended Filters
134
Types of Coordination
134
Fuseless Version
135
Fused Version (Line Protection Only)
136
Fused Version with SITOR 3NE1 Fuses
137
Fused Version with SITOR 3NE3/4/8 Fuses
138
Overview
140
Rw40
140
3RW40 2., 3., 4. Control Electronics
141
3RW40 5., 7. Control Electronics
142
3RW40 2., 3., 4. Control Electronics
142
3RW40 5., 7. Control Electronics
143
3RW40 Protection Functions
143
3RW40 Control Times and Parameters
144
3RW40 2. to 7. Power Electronics
145
3RW40 24, 26, 27, 28 Power Electronics
146
3RW40 36, 37, 38, 46, 47 Power Electronics
147
3RW40 55, 56, 73, 74, 75, 76 Power Electronics
148
3RW40 2., 3., 4. Main Conductor Cross-Sections
149
3RW40 5., 7. Main Conductor Cross-Sections
150
3Rw40
151
Electromagnetic Compatibility According to en 60947-4-2
151
Recommended Filters
152
Types of Coordination
152
Fuseless Version
153
Fused Version (Line Protection Only)
154
Fused Version with SITOR 3NE1 Fuses
155
Fused Version with SITOR 3NE3/4/8 Fuses
156
Motor Protection Tripping Characteristics for 3RW40 (with Symmetry)
157
Motor Protection Tripping Characteristics for 3RW40 (with Asymmetry)
158
15 Dimension Drawings
159
Cax Data
159
16 Typical Circuit Diagrams
161
Typical Circuit for the Optional Thermistor Motor Protection Evaluation
161
Control by Pushbutton
162
Control of the 3RW30 by Pushbutton
162
Control of the 3RW40 by Pushbutton
163
Control by Switch
165
Control of the 3RW30 by Switch
165
Control of the 3RW40 by Switch
166
Control in Automatic Mode
168
Control of the 3RW30 in Automatic Mode
168
Control of the 3RW40 in Automatic Mode
169
Control by PLC
171
Control of the 3RW30 with 24 V DC by PLC
171
Control of the 3RW40 by PLC
172
Control with an Optional Main / Line Contactor
174
Control of the 3RW30 with a Main Contactor
174
Control of the 3RW40 with a Main Contactor
175
Reversing Circuit
177
3RW30 Reversing Circuit
177
3RW40 Reversing Circuit
178
Control of a Magnetic Parking Brake
180
3RW30 Motor with Magnetic Parking Brake
180
3RW402 - 3RW404, Control of a Motor with a Magnetic Parking Brake
181
3RW405 - 3RW407, Control of a Motor with a Magnetic Parking Brake
182
Emergency Stop
183
3RW30 EMERGENCY STOP and 3TK2823 Safety Relay
183
3RW402 - 3RW404 EMERGENCY STOP and 3TK2823 Safety Relay
185
3RW405 - 3RW407 EMERGENCY STOP and 3TK2823 Safety Relay
187
3RW and Contactor for Emergency Starting
189
3RW30 and Contactor for Emergency Starting
189
3RW40 and Contactor for Emergency Starting
190
Dahlander / Multispeed Motor
192
3RW30 and Dahlander Motor Starting
192
3RW402 - 3RW404 and Dahlander Motor Starting
194
3RW405 - 3RW407 and Dahlander Motor Starting
195
Appendix
197
Configuration Data
197
A.1 Configuration Data
197
Table of Parameters Used
199
Index
201
Siemens SIRIUS 3RW30 Operating Instructions Manual (22 pages)
Brand:
Siemens
| Category:
Controller
| Size: 0.85 MB
Advertisement
Siemens SIRIUS 3RW30 Assembly Instructions Manual (8 pages)
AC Semiconductor Motor Controller
Brand:
Siemens
| Category:
Controller
| Size: 0.39 MB
Table of Contents
Hazardous Voltage
4
Wichtiger Hinweis
5
Remarque Importante
5
Avvertenza Importante
5
Siemens SIRIUS 3RW30 Assembly Instructions (4 pages)
AC Semiconductor Motor Controller
Brand:
Siemens
| Category:
Industrial Equipment
| Size: 0.32 MB
Advertisement
Related Products
Siemens SIRIUS 3RW301
Siemens SIRIUS 3RW304
Siemens SIRIUS 3RW302
Siemens SIRIUS 3RW303
Siemens SIKOSTART 3RW34
Siemens SIKOSTART 3RW35
Siemens Sirius 3RW44 V.7.1
Siemens SIRIUS 3RW44 PCS 7
Siemens SIRIUS 3RW40 5
Siemens SIRIUS 3RW44 2 Series
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL