Manuals and User Guides for Siemens Synco 900. We have
3
Siemens Synco 900 manuals available for free PDF download: Basic Documentation, Mounting And Commissioning, Operating Instructions Manual
Siemens Synco 900 Basic Documentation (120 pages)
Communication via the KNX bus
Brand:
Siemens
| Category:
Controller
| Size: 1.98 MB
Table of Contents
Table of Contents
3
1 KNX (Konnex) and Synco
7
General Overview
7
Definition of Terms
8
Synco 700, 900, RXB/RXL Range
10
Collective Terms for the Device Types
11
Product Markings on Synco Bus Devices
11
The KNX Network
12
Full-Scale KNX Network
12
Network Address
13
Device Address
14
Area/Line Couplers and IP Router
15
2 Engineering Notes
17
Designing the Network
17
Design Engineering Procedure
17
Number of Bus Devices Per Line, Area and Network
18
Bus Load Number E
18
Bus Power Supply
19
Decentral Bus Power Supply
19
Power Consumption of the Bus Devices
20
Central Bus Power Supply
21
Bus Topologies
22
Distances and Cable Lengths
23
3 Commissioning Notes
25
Points to Check Prior to Commissioning
25
Commissioning with the RMZ Operator Units
26
Starting Commissioning, Plant Mode "Off
26
Terminating Commissioning, Plant Mode "Auto
28
4 Device Address and Device Name
29
Reading the Area, Line and Device Address
29
Assigning Device Names
30
Setting Device Address with RMZ790 and RMZ791 Operator Units
32
5 Device Addresses Via ACS
33
Service Tool OCI700.1 and ACS7
33
Overview
33
New Plant
34
Establishing a Connection
35
Edit Device List
35
Addressing Devices with the OCI700.1 Service Tool
37
Assigning Addresses Manually
38
Assigning Addresses Automatically
39
Assigning Addresses in Programming Mode
40
Addressing Via the ID Number
41
Device Address for the Ozw771.XX Central Communication Units
42
Other Addressing Options, Ozw771.XX
43
Restoring the Factory Settings, Ozw771.XX
43
Device Address for the OZW775 Central Communication Unit
44
Device Address for the QAX910 Central Apartment Unit
45
Device Address for the RXB/RXL Room Controllers
48
RXB/RXL Device Address with QAX34.3 Room Unit
49
Device Address for the QAW740 Room Unit
51
Device Address for RMZ792 Bus Operator Unit
53
Addressing the Couplers
56
Line Couplers
56
Area Couplers
58
5.10 Addressing the IP Router
59
5.10.1 KNX Network Address
59
6 Basic Communication Settings
61
Decentral Bus Power
61
Clock Time Operation
61
Setting a Time Slave Remotely
62
Remote Reset of Fault
64
Basic Settings Via ACS
65
7 Communication Via Zone Addresses
67
General Notes on Zones
67
Synco Zoning
67
Communication of Process Values
68
Geographical Zone (Apartment)
69
Default
70
Zone Addressing with the RMZ Operator Units
72
QAWZ740 Room Unit
73
Addressing the Zones with ACS
74
RXB/RXL Room Controllers
75
Zone Addressing with the QAX34.3 Room Unit
75
8 Large Plants
77
Engineering and Commissioning
77
Network Topologies
78
IP Router as a Coupler to the IP Network
81
LTE Filter Table for Couplers and IP Routers
84
Filter Settings
84
Predefined LTE Filter Table
85
Filtering, Zone Addresses, Communication Areas
86
LTE Telegrams Via Couplers and IP Routers
87
System Time, Alarms and Remote Time Adjustments
89
Engineering of Large Plants
90
9 Appendix
93
Faults and Errors
93
Bus Fault Status Message
93
Communication Errors
94
Heating / Cooling Changeover
95
Changeover Via Digital Input
96
Changeover Via Analog Input
97
Changeover Based on Calendar
98
H/C Changeover Relay and Fault Messages
99
Room Control Combination
100
Application Examples
100
Applications with Zones
104
Additional Zones in the RXB/RXL Room Controller
105
Supply Chains
106
Data Exchange in LTE Mode
108
Updating the Process Values
109
Lightning and Overvoltage Protection, EMC
110
Lightning Protection
110
Overvoltage Protection
113
Overvoltages in Loops
114
EMC Protection Management
115
Advertisement
Siemens Synco 900 Operating Instructions Manual (76 pages)
Brand:
Siemens
| Category:
Thermostat
| Size: 2.45 MB
Table of Contents
Operating Instructions
1
Symbols Used
3
Table of Contents
4
Safety Notes
8
System Overview
9
System Functions
9
Central Unit
9
Heating Control
9
DHW Heating
10
Release of Ventilation
10
Weather Station
11
Light and Blind Control
11
Supervisory Functions
12
Alarms
12
Supervision of Devices
12
System Components
13
Central Apartment Unit QAX910
15
Operating Elements
15
Display
17
Symbols on the Display
18
Operation
20
Quiescent Picture
20
Info Pages
20
Menu Level
21
Setting Principle
21
Access Levels
23
Settings
24
General
24
Absence
24
Heating
25
Apartment Timer Function
25
Apartment Operating Mode
25
Apartment Operating Mode Switch
26
Summer Operation of Heating
26
State of Winter Operation / Summer Operation
27
Beginning of Summer / End of Summer
27
Summer / Winter Changeover Temperature
27
Antilime Function
27
Room Operating Modes
28
State of Room Operating Mode
28
Reason for Room Operating Mode
29
Room Operating Mode During Absence
29
Room Temperature Setpoints
30
Readjustment of Room Unit
30
Setting the Time Switch of a Room
31
Actual Value of the Room Temperature
32
Room Temperature Setpoint
33
Setpoint Limitation
33
Valve Position
33
Apartment Timer Influence
33
Optimum Start / Stop Control
34
Room Temperature Supervision
34
Window Airing Function
35
Silent Mode
35
Actuator Calibration
36
Sensor Readjustment
36
Dhw
37
DHW Operating Mode
37
Forced DHW Charging
37
State of DHW Operating Mode
37
Reason for DHW Operating Mode
37
DHW Operating Mode During Absence
38
DHW Temperature Setpoint
38
DHW Time Switch
38
Actual Value of the DHW Temperature
39
DHW Temperature Setpoint
39
Operating State of Charging Pump and Electric Immersion Heater
39
Plant Operation
39
Reason for DHW Plant Operation
39
Limitation of Charging Time
39
Changeover to Electric Immersion Heater
40
Supervision of the DHW Temperature
40
Switching Groups
40
Operating the Switching Groups
40
Scenes
41
Triggering Switching Groups Via an Event
42
Time Switch for Switching Groups
44
Time Switch for Simulation of Presence
44
Activating Simulation of Presence
45
Holidays/Special Days
47
Setting Holidays / Special Days
47
Holidays and Absence Simultaneously
48
Room Operating Mode During Holidays
48
DHW Operating Mode During Holidays
48
Time Settings
49
Date / Time of Day
49
Faults
49
Error / Fault Status Messages
49
Fault Status Messages Bus
49
Acknowledging Faults
50
Inputs / Outputs
50
Displaying Input Signals
50
Displaying Output States
50
Settings
51
Language
51
Elevation above Sea Level
51
Time-Of-Day Format
51
Backlit Display / Display Contrast
51
Display Format
52
Temperature Display
52
Password for the Service Level
53
Direct Selection of Info Pages
53
Fault Inputs 1 - 4
54
Fault Outputs 1 and 2
55
Release of Supervision
56
Supervision Delay
57
Event Buzzer and Status Output
57
Signal Duration
57
Plant Name
58
Room Names 1 - 12
58
Switching Group Names 1 - 8
58
Lamp Names 1 - 4
58
Info Lines
58
Room Unit QAW910
59
Operation
59
Room Operating Modes
59
Room Timer Function
60
Readjustment of the Room Temperature Setpoint
61
Display
61
Error Messages
63
Maintenance
64
Monitoring the Batteries
64
Room Unit QAW910
64
Door / Window Contact Wave AP 260
64
DELTA Reflex Smoke Detector
64
Manual Capacity Check
64
Replacing the Batteries
65
Room Unit QAW910, Room Sensor QAA910 and Meteo Sensor QAC910
65
Radiator Control Actuator SSA955
66
Door / Window Contact Wave AP 260 and DELTA Reflex Smoke Detector
67
Maintenance
59
Binding Tests
68
Function Button on the Room Unit, Room Sensor, Meteo Sensor, Radio Repeater and Radiator Control Actuator
68
Function Button on the Heating Circuit Controllers RRV912 and RRV918
69
Maintenance and Cleaning
69
Disposal
69
Gubelstrasse
76
Siemens Synco 900 Mounting And Commissioning (88 pages)
Brand:
Siemens
| Category:
Temperature Controller
| Size: 2.25 MB
Table of Contents
Table of Contents
4
Safety Notes
7
Mounting and Installation
8
Mounting the Central Apartment Unit
8
Mounting Regulations
8
Mounting Location
8
Dimensions of the Central Apartment Unit
9
Dimensions of the Base
9
Mounting Procedure
10
Electrical Installation of the Central Apartment Unit
12
Installation Regulations
12
Connection Terminals / Wiring
12
Commissioning the System
14
Prerequisites
14
Procedure
14
Basic Configuration of the Central Apartment Unit
14
Switch on the Central Apartment Unit
14
Change to the Expert Level
15
Select the Commissioning Menu
16
Configure Rooms
16
Configure DHW Charging
19
Configure the Switching Groups
21
Configure Doors
24
Configure Light Status Indication
25
Display Fault Status Message Bus
26
Configure Fault Inputs and Outputs
26
Configure Inputs
27
Configure Outputs
31
Configure RF Repeaters
36
Configure Info Pages
37
Configure Cooling Mode
38
Connecting RF Components
38
Notes
38
Connect RF Room Components
38
Connect Smoke Detectors
43
Connect DHW Components
44
Connect Meteo Sensor
46
Connect Light and Blind Actuators
46
Connect the Switching Group Relay
47
Connect Door Contacts
48
Connect Fault Inputs
48
Connect Fault Outputs
48
Connect Inputs
49
Connect Outputs
51
Connect Hager Tebis Devices
54
Connect RF Repeaters
55
Testing Radio Connections
57
Wiring Test
57
Removing Devices
58
Displaying the Device List by Function
59
Displaying the Device List with All Devices
59
Remove Devices from the Device List
60
Bus Communication
60
Device Address KNX TP1
60
Bus Power Supply
60
Programming Mode
61
Clock Time Operation
61
Remote Setting Clock Slave
61
Calendar Zone (Holidays and Special Days)
62
DHW Zone
62
Set the Distribution Zone
63
Quitting the "Commissioning" Menu
63
Function Settings
64
General
64
Buzzer Volume
64
Password Expert Level
64
Heating
65
Enable Setpoint Limitation
65
Limitation Setpoint
65
Pump Overrun Time
65
Valve Override
65
Room Temperature Rise
66
Proportion Room Unit
66
Valve Position Cooling Mode / Summer Operation
66
Minimum Valve Position Comfort
67
Room Controller Settings
68
P-Band Xp
68
Integral Action Time Tn
68
Derivative Action Time Tv
69
Neutral Zone
69
Switching Differential 2-Position
70
Actuator Running Time
70
Dhw
71
Frost Protection Setpoint
71
Legionella Setpoint
71
Legionella Protection Frequency
71
Legionella Protection Time
71
Legionella Protection Period
72
DHW Priority
72
Switching Differential
72
Charging Time Max
73
Forced Charging
73
Setpoint Boost DHW Charging
74
System Pump Required
74
Summer Operation Electric Immersion Heater
74
Switching Groups
75
Scene Number
75
Time of Day / Date
75
Summer Time Start / Winter Time Start
75
Faults
76
Fault History
76
Delete Faults
76
Texts
76
File Name
76
Business Card Title and Lines 1 - 4
77
Heat Request
77
Flow Temperature Min
77
Flow Temperature Max
77
Temperature Request Winter Operation
78
Temperature Request 0..10 V
78
Data Backup
79
System Limits
79
Communication
80
Maintenance / Service
80
Peripheral Devices
80
Restore Factory Settings
80
Manual Control of the Radiator Control Actuator
80
Disposal
80
Index
81
Advertisement
Advertisement
Related Products
Siemens S55770-T104
Siemens S55770-T334
Siemens S55770-T293
Siemens S55770-T400
Siemens S55770-T350
Siemens S55770-T429
Siemens S5577Q-T1Q4
Siemens S5577Q-T105
Siemens S5577Q-T334
Siemens S5577Q-T293