INSTALLATION INSTRUCTIONS

Installation clearances
The location must be large enough to fully open the
dryer door.
Dryer Dimensions
* Most installations require a minimum 5
(14 cm) clearance behind the dryer for the
exhaust vent with elbow.
Minimum installation spacing for a recessed
area, customized undercounter or closet
installation
The following dimensions shown are for the
minimum spacing allowed.
Additional spacing should be considered for
installation and servicing.
Additional clearances might be required for wall,
door and floor moldings.
Additional spacing of 1 in. (2.5 cm) on all sides of
the dryer is recommended to reduce noise
transfer.
For closet installation with a door, minimum
ventilation openings in the top and bottom of the
door are required. Louvered doors with
equivalent ventilation openings are acceptable.
Companion appliance spacing should also be
considered.
6
Closet installation
Closet installation - Dryer only
(7.6 cm)
48"
(310 cm
43"
(109.22 cm)
24"
(155 cm
(7.6 cm)
1
/
in.
2
0"
(0cm)
3"
2
2
)
2
2
)
3"
27"
(0cm)
(68.6 cm)
14" max
(35.6 cm)
18"
(45.72 cm)
1"
31.5"
(2.54cm)
(80.01cm)
(2.54cm)
0"
1"

Advertisement

Table of Contents
loading

Summary of Contents for LG DLE0332

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS Installation clearances Closet installation - Dryer only Closet installation The location must be large enough to fully open the dryer door. Dryer Dimensions 3" 14" max (7.6 cm) (35.6 cm) 48" 18" (45.72 cm) (310 cm 43" (109.22 cm) 24"...
  • Page 2: Installing The Dryer

    INSTALLING THE DRYER Step 1 : Position and Level the Dryer DO NOT use plastic or thin foil ducting. For further assistance refer to section on Location Locate dryer so exhaust duct is as short as Requirements. possible. Be certain old ducts are cleaned before installing Place the dryer in position, and adjust the legs until the your new dryer.
  • Page 3 INSTALLING THE DRYER Step 3 : Connect Gas Supply Pipe (Gas Dryer ONLY) For further assistance, refer to section on Gas Requirements. 1. Make certain your dryer is equipped for use with the 3. Connect to gas supply pipe using a new flexible type of gas in your laundry room.
  • Page 4: Heat Source Check

    Step 4: (Electric Dryer Only) Connect Heat Source Check Electrical Plug Electric Dryers For further assistance refer to section on Electrical Requirements. Close the loading door and start the dryer in a heat setting (refer to the Operating Instructions supplied with IMPORTANT : Use only a new U.L.
  • Page 5: Door Reversal Procedure

    DOOR REVERSAL PROCEDURE The door on this dryer is completely reversible. Remove screw & exhaust duct. To reverse door proceed as follows: Detach and remove the bottom, left or right side knockout as desired. Reconnect the new duct[11 in(28cm)] to the blower housing, and Fixing the duct to the base.
  • Page 6: Manufactured (Mobile) Home Installation

    MANUFACTURED (MOBILE) HOME INSTALLATION IMPORTANT : Installation must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 32-80 or Standard CAN/CSA-Z240 MH. Dryer exhaust duct MUST NOT terminate under the The dryer can be installed in a manufactured (mobile) mobile home.
  • Page 7: Electrical Requirements - Electrical Dryer

    ELECTRICAL REQUIREMENTS - ELECTRICAL DRYER Electric Dryers The dryer has its own terminal block that must be connected to a separate branch, 60 Hertz, single phase (120V/240 Volt, 60 Hertz, 3-Wire Installation) circuit, AC (alternating current) circuit, fused at 30 (120V/208 Volt, 60 Hertz, 3-Wire Installation) Amperes (the circuit must be fused on both sides of NOTE : The wiring diagram is located inside the...
  • Page 8 Electrical Connection Options 1. Remove center terminal block screw. 2. Remove appliance ground wire (green) from external If your home has: And you will be Go to Section ground connector screw. Fasten it under center, silver connecting to colored terminal block screw. 4-wire receptacle A UL listed, 120/240 4-wire connection:...
  • Page 9 ELECTRICAL REQUIREMENTS - ELECTRICAL DRYER When connecting to the terminal block, place the hooked 3-wire connection: Power supply cord end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten Use where local codes permit connecting screw.
  • Page 10 3-wire connection: Direct wire Optional 3-wire connection Use where local codes permit connecting Use where local codes permit connecting cabinet-ground conductor to neutral wire. cabinet-ground conductor to neutral wire. Direct wire cable must have 5 ft (1.52 m) of extra 1.
  • Page 11: Electrical Requirements - Gas Dryer

    ELECTRICAL REQUIREMENTS - GAS DRYER NOTE : A qualified electrician should check the Gas Dryers polarity of the wall receptacles. If a voltage reading is (120 Volt, 60 Hertz, with 3-Prong Grounding Plug) measured other than that illustrated, the qualified electrician should correct the problem.
  • Page 12: Grounding Instructions

    Grounding Instructions The dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The dryer is equipped with a cord having an equipment-grounding conductor and a three prong grounding plug.
  • Page 13: Gas Requirements

    GAS REQUIREMENTS Gas Dryers NOTE : The gas service to a gas dryer must conform When a rigid pipe is used it should be 1/2 inch IPS. with the local codes and ordinances or, in the absence When acceptable to the gas supplier and local codes, 3/8- of local codes and ordinances, with the latest edition inch approved tubing may be used for lengths under 6.1 of the National Fuel Gas Code ANSI Z223.1/NFPA...
  • Page 14: Exhaust Requirements

    EXHAUST REQUIREMENTS Exhaust System Materials WARNING Exhaust system materials are not supplied with the dryer. A clothes dryer produces combustible lint. Exhaust duct must be four inches (10.2 cm) in diameter To reduce the risk of fire or gas having no obstructions. Rigid metal duct is accumulation, the dryer MUST be recommended.
  • Page 15 EXHAUST REQUIREMENTS Weather Hood Type Number of 90° Elbows Use Only for Short Run Installations Recommended 4” 4” 2-1/2” (10.2 cm) (10.2 cm) (6.35 cm) Maximum length of 4” (10.2 cm) diameter rigid metal duct 65 feet (19.8 m) 55 feet (16.8 m) 55 feet (16.8 m) 47 feet (14.3 m) 47 feet (14.3 m)
  • Page 16: Exhaust System Maintenance

    Exhaust System Maintenance Dryer Airflow The dryer interior and the complete exhaust system Efficient dryer operation requires proper dryer airflow. should be inspected after one year of use and cleaned if Proper dryer airflow can be evaluated by measuring the necessary.