Installing or Replacing Server Components
d.
If this is the first time that NVMe PCIe SSDs are being installed in the server, you must install a PCIe
Note
interposer board and connect its cables before installing the drive. See
Board, page
Step 2
Install a new NVMe PCIe SSD:
a.
b.
c.
Step 3
Observe the drive-tray LED and wait until it returns to solid green before accessing the drive:

Installing a PCIe Interposer Board

A PCIe interposer board is used to provide communication with the PCIe bus from the NVMe PCIe SSDs
in the front panel bays. Use the correct interposer board, with bundled cables, for your version of the
server:
Cisco UCS C240 M4 Server Installation and Service Guide
3-20
If you are replacing an existing SSD, remove the four drive tray screws that secure the SSD to the
tray and then lift the SSD out of the tray.
3-20.
Place a new SSD in the empty drive tray and replace the four drive tray screws.
With the ejector lever on the drive tray open, insert the drive tray into the empty drive bay.
Push the tray into the slot until it touches the backplane, and then close the ejector lever to lock the
drive in place.
Off—The drive is not in use.
Green, blinking—the driver is initializing following hot-plug insertion.
Green—The drive is in use and functioning properly.
SFF 8-drive or 16-drive: UCSC-IP-SSD-240M4
SFF 24-drive: UCSC-IP-SSD-240M4B