hit counter script

Cisco c240 Installation And Service Manual page 67

Ucs c240 m4 server
Table of Contents

Advertisement

Chapter 3
Maintaining the Server
Lift the heatsink off of the CPU.
b.
Open the CPU retaining mechanism:
Step 6
Unclip the first retaining latch labeled with the
a.
latch labeled with the
Open the hinged CPU cover plate.
b.
Figure 3-14
3
1
CPU retaining latch
2
CPU retaining latch
3
Hinged CPU cover plate
Step 7
Remove any existing CPU:
With the latches and hinged CPU cover plate open, swing the CPU in its hinged seat up to the open
a.
position, as shown in
b.
Grasp the CPU by the finger-grips on its plastic frame and lift it up and out of the hinged CPU seat.
c.
Set the CPU aside on an antistatic surface.
Install a new CPU:
Step 8
Grasp the new CPU by the finger-grips on its plastic frame and align the tab on the frame that is
a.
labeled "ALIGN" with the hinged seat, as shown in
Insert the tab on the CPU frame into the seat until it stops and is held firmly.
b.
The line below the word "ALIGN" should be level with the edge of the seat, as shown in
Swing the hinged seat with the CPU down until the CPU frame clicks in place and holds flat in the
c.
socket.
Close the hinged CPU cover plate.
d.
Clip down the CPU retaining latch with the
e.
with the
OL-32474-01
icon. See
CPU Socket
1
4
Figure
3-14.
icon. See
Figure
3-14.
Installing or Replacing Server Components
icon, and then unclip the second retaining
Figure
3-14.
5
2
4
Hinged CPU seat
5
Finger-grips on plastic CPU frame
Figure
3-15.
icon, and then clip down the CPU retaining latch
Cisco UCS C240 M4 Server Installation and Service Guide
Figure
3-15.
3-25

Advertisement

Table of Contents
loading

Table of Contents