INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS

R em ark :
• Detail of accessory and installation parts can
see in the accessory sheet.
• Som e pictures m ight be different from the
actual parts.

Optional Installation Parts

Part
Parts name
code
Refrigerant piping
Liquid side
: 06.35 mm
Gas side
: 09.52 mm
(B10, B13N3KVP Series)
: 012.7 mm
(B16N3KVP Series)
Pipe insulating material
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
©
Fixing bolt arrangement of outdoor unit
• Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be
exposed to a strong wind.
Q'ty
• Use 0 8 mm or 010 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple ® and cap
water proof ® to the bottom plate of the outdoor unit before installing it.
One
each
1
One
each
w
When using a multi-system outdoor unit is used, refer to the installation
manual provided with the model concerned.
3
For the rear left and left piping
Do not allow the drain hose to get slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose sloped
downward.
v ___________________________________ y
r
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
* Drain nipple and
cap water proof are
packed in outdoor
unit.
D ra in o u tle t