Heronhill - for all your Toshiba requirements 1. SAFETY PRECAUTIONS For general public use Power supply cord of outdoor unit shall be more than 1.5 mm² (H07RN-F or 245IEC66) polychloroprene sheathed flexible cord. • Read this “SAFETY PRECAUTIONS” carefully before servicing.
Page 4
Heronhill - for all your Toshiba requirements • DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS. FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION. • TO PREVENT THE INDOOR UNIT FROM OVERHEATING AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM HEAT SOURCES SUCH AS RADIATORS, HEAT RESISTORS, FURNACE, STOVES, ETC.
A 1-room connection is not an option for the indoor units (you cannot connect only one indoor unit). Be sure to connect indoor units in two rooms or more. The contents noted in this service manual limit the indoor units to the RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E, RAS-M10GKCVP-E, RAS-M13GKCVP-E and RAS-M16GKCVP-E.
Heronhill - for all your Toshiba requirements 2-1. Specifications <Heat Pump Models> RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E / RAS-4M27GAV-E, RAS-3M26GAV-E Indoor RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E Unit model Outdoor RAS-4M27GAV-E RAS-3M26GAV-E Cooling capacity (kW) Cooling capacity range (kW) 1.4 – 9.2 1.4 – 8.9...
Page 7
Heronhill - for all your Toshiba requirements <Cooling Only Models> RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E / RAS-4M27GACV-E Indoor RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E Unit model Outdoor RAS-4M27GACV-E Cooling capacity (kW) Cooling capacity range (kW) 1.4 – 9.2 Heating capacity (kW) — Heating capacity range (kW) —...
Page 8
Heronhill - for all your Toshiba requirements 2-2. Specifications of Performance When Each Indoor Unit is Combined with Other Unit Outdoor Unit : RAS-4M27GAV-E <Cooling/220V> Power Indoor unit Unit capacity (kW) Cooling Power Operating Outdoor Operating supply capacity consumption current...
Page 9
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-4M27GAV-E <Cooling/230V> Power Indoor unit Unit capacity (kW) Cooling Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 3.71 1 unit – – – – – –...
Page 10
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-4M27GAV-E <Cooling/240V> Power Indoor unit Unit capacity (kW) Cooling Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 3.55 1 unit – – – – – –...
Page 11
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-4M27GAV-E <Heating/220V> Power Indoor unit Unit capacity (kW) Heating Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 1450 6.73 1 unit – – – – –...
Page 12
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-4M27GAV-E <Heating/230V> Power Indoor unit Unit capacity (kW) Heating Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 1450 6.43 1 unit – – – – –...
Page 13
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-4M27GAV-E <Heating/240V> Power Indoor unit Unit capacity (kW) Heating Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 1450 6.16 1 unit – – – – –...
Page 14
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-4M27GACV-E <Cooling/220V> Power Indoor unit Unit capacity (kW) Cooling Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 3.87 1 unit – – – – – –...
Page 15
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-4M27GACV-E <Cooling/230V> Power Indoor unit Unit capacity (kW) Cooling Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 3.71 1 unit – – – – – –...
Page 16
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-4M27GACV-E <Cooling/240V> Power Indoor unit Unit capacity (kW) Cooling Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 3.55 1 unit – – – – – –...
Page 17
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-3M26GAV-E <Cooling/220V> Power Indoor unit Unit capacity (kW) Cooling Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 3.87 1 unit – – – – (1.4 to 3.2) (640 to 950) (3.68 to 4.64)
Page 18
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-3M26GAV-E <Cooling/230V> Power Indoor unit Unit capacity (kW) Cooling Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 3.71 1 unit – – – – (1.4 to 3.2) (640 to 950) (3.52 to 4.44)
Page 19
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-3M26GAV-E <Cooling/240V> Power Indoor unit Unit capacity (kW) Cooling Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 3.55 1 unit – – – – (1.4 to 3.2) (640 to 950) (338 to 4.26)
Page 20
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-3M26GAV-E <Heating/220V> Power Indoor unit Unit capacity (kW) Heating Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 1500 6.96 1 unit – – – – (0.8 to 5.2) (300 to 1980) (1.87 to 9.18)
Page 21
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-3M26GAV-E <Heating/230V> Power Indoor unit Unit capacity (kW) Heating Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 1500 6.65 1 unit – – – – (0.8 to 5.2) (300 to 1980) (1.79 to 8.78)
Page 22
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-3M26GAV-E <Heating/240V> Power Indoor unit Unit capacity (kW) Heating Power Operating Outdoor Operating supply capacity consumption current noise status (kW) (dB) 1500 6.38 1 unit – – – – (0.8 to 5.2) (300 to 1980) (1.71 to 8.42)
Page 23
Heronhill - for all your Toshiba requirements 2-2-1. Operation Characteristic Curve <Cooling> <Heating> • Conditions • Conditions 220V Indoor : DB27˚C/WB19˚C Indoor : DB20˚C 220V Outdoor : DB35˚C Outdoor : DB7˚C / WB6˚C Air flow : High Air flow : High...
Heronhill - for all your Toshiba requirements 3. REFRIGERANT R410A This air conditioner adopts the new refrigerant HFC 6. When an air conditioning system charged with a (R410A) which does not damage the ozone layer. large volume of refrigerant is installed in a small...
Page 25
Heronhill - for all your Toshiba requirements Table 3-2-1 Thicknesses of annealed copper pipes Thickness (mm) Nominal diameter Outer diameter (mm) R410A 6.35 0.80 0.80 9.52 0.80 0.80 12.70 0.80 0.80 15.88 1.00 1.00 2. Joints For copper pipes, flare joints or socket joints are used. Prior to use, be sure to remove all contaminants.
Page 26
Heronhill - for all your Toshiba requirements d) Flare Processing Make certain that a clamp bar and copper pipe have been cleaned. ØD By means of the clamp bar, perform the flare processing correctly. Use either a flare tool for R410A or conven- tional flare tool.
Page 27
Heronhill - for all your Toshiba requirements Table 3-2-6 Flare and flare nut dimensions for R22 Dimension (mm) Nominal Outer diameter Thickness Flare nut width diameter (mm) (mm) (mm) 6.35 9.52 13.0 13.5 12.70 16.2 16.0 12.9 15.88 19.7 19.0 16.0...
Page 28
Heronhill - for all your Toshiba requirements 3-3. Tools 3-3-1. Required Tools The service port diameter of packed valve of the outdoor unit in the air-water heat pump using R410A is changed to prevent mixing of other refrigerant. To reinforce the pressure-resisting strength, flare processing dimensions and opposite side dimension of flare nut (For Ø12.7 copper pipe) of the refrigerant piping are...
Heronhill - for all your Toshiba requirements 3-4. Recharging of Refrigerant When it is necessary to recharge refrigerant, charge the specified amount of new refrigerant according to the following steps. Recover the refrigerant, and check no refrigerant remains in the equipment.
Page 30
Heronhill - for all your Toshiba requirements 1. Be sure to make setting so that liquid can be charged. 2. When using a cylinder equipped with a siphon, liquid can be charged without turning it upside down. It is necessary for charging refrigerant under condition of liquid because R410A is mixed type of refrigerant.
Page 31
Heronhill - for all your Toshiba requirements 2. Characteristics required for flux 3-5-3. Brazing • Activated temperature of flux coincides with the As brazing work requires sophisticated techniques, brazing temperature. experiences based upon a theoretical knowledge, it must be performed by a person qualified.
Heronhill - for all your Toshiba requirements 4. CONSTRUCTION VIEWS 4-1. Indoor Unit RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E Plasma pure filter Indoor heat exchanger Front panel Air filter Zeolite-plus filter Air ionizer Knockout system Knockout system 54.5 Remote controller holder 54.5...
Page 33
Heronhill - for all your Toshiba requirements 4-2. Outdoor Unit RAS-4M27GAV-E, RAS-4M27GACV-E, RAS-3M26GAV-E Knock out 88 × 20 hole 3-Ø3. 5 hole Knock out Anchor bolt (4-Ø12 × 17 hole) Fan guard Handle Liquid valve Gas valve Service port Outdoor air temperature sensor...
Page 34
Heronhill - for all your Toshiba requirements To outdoor unit Color Identification WHITE BLACK BLUE BROWN ORANGE PURPUL YELLOW GRAY PINK GRN& GREEN& INDOOR 1 2 3 4 YELLOW TERMINAL BLOCK 1 2 3 4 Heat exchanger Ion electrode GRN & YEL...
Page 35
Heronhill - for all your Toshiba requirements 5-2. Outdoor Unit RAS-4M27GAV-E, RAS-4M27GACV-E, RAS-3M26GAV-E Color Identification NOTE BLK : BLACK WHI : WHITE IGBT : Insulated Gate Bipolar BLU : BLUE BRW : BROWN Transistor RED : RED ORN : ORANGE...
Heronhill - for all your Toshiba requirements 6. SPECIFICATIONS OF ELECTRICAL PARTS 6-1. Indoor Unit RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E Parts name Type Specifications Fan motor (for indoor) MF-280-30-5R DC280–340V, 30W Room temp. sensor (TA-sensor) ( – ) 10kΩ at 25°C Heat exchanger temp.
Heronhill - for all your Toshiba requirements 7. REFRIGERANT CYCLE DIAGRAM RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E / RAS-4M27GAV-E Temp. measurement Indoor unit A D room C room B room D room C room B room Evaporator Cross flow fan Per 1 unit Max.
Page 38
Heronhill - for all your Toshiba requirements RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E / RAS-4M27GACV-E Temp. measurement D room C room B room D room C room B room Indoor unit A Evaporator Cross flow fan Per 1 unit Max. : 25m Min. : 2m Connecting pipe Thickness : 0.8mm...
Page 39
Heronhill - for all your Toshiba requirements RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E / RAS-3M26GAV-E Temp. measurement Indoor unit A C room B room C room B room Evaporator Cross flow fan Per 1 unit Connecting pipe Max. : 25m Min. : 2m Thickness : 0.8mm...
Heronhill - for all your Toshiba requirements 7-2. Operation Data Outdoor Unit : RAS-4M27GAV-E <Cooling> Temperature Operating combination Heat exchanger No. of Standard Compressor condition (Unit) pipe temp. Indoor Outdoor operating pressure revolution units P (MPa) (rps) Indoor Outdoor T1 (°C) T2 (°C)
Page 41
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-4M27GAV-E <Heating> Temperature Operating combination Heat exchanger No. of Standard Compressor condition (Unit) pipe temp. Indoor Outdoor operating pressure revolution units P (MPa) (rps) Indoor Outdoor T1 (°C) T2 (°C) 1 unit –...
Page 42
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-4M27GACV-E <Cooling> Temperature Operating combination Heat exchanger No. of Standard Compressor condition (Unit) pipe temp. Indoor Outdoor operating pressure revolution units P (MPa) (rps) Indoor Outdoor T1 (°C) T2 (°C) 1 unit –...
Page 43
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-3M26GAV-E <Cooling> Temperature Operating combination Heat exchanger No. of Standard Compressor condition (Unit) pipe temp. Indoor Outdoor operating pressure revolution units P (MPa) (rps) Indoor Outdoor T1 (°C) T2 (°C) 1 unit –...
Page 44
Heronhill - for all your Toshiba requirements Outdoor Unit : RAS-3M26GAV-E <Heating> Temperature Operating combination Heat exchanger No. of Standard Compressor condition (Unit) pipe temp. Indoor Outdoor operating pressure revolution units P (MPa) (rps) Indoor Outdoor T1 (°C) T2 (°C) 1 unit –...
Heronhill - for all your Toshiba requirements 8. CONTROL BLOCK DIAGRAM 8-1. Indoor Unit RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E Indoor Unit Control Unit M.C.U. Louver Functions Motor Heat Exchanger Sensor (Tc) • Cold draft preventing Function Room Temperature Sensor (Ta) Louver Motor •...
Page 46
Heronhill - for all your Toshiba requirements RAS-M10GKCVP-E, RAS-M13GKCVP-E, RAS-M16GKCVP-E Indoor Unit Control Unit M.C.U. Louver Functions Motor Heat Exchanger Sensor (Tc) • 3-minute Delay at Restart for Compressor Room Temperature Sensor (Ta) Louver Motor Drive Control • Fan Motor Starting Control...
Page 47
Heronhill - for all your Toshiba requirements 8-2. Outdoor Unit (Inverter Assembly) RAS-4M27GAV-E, RAS-4M27GACV-E, RAS-3M26GAV-E Outdoor air temp. Sensor Gas side pipe temp. Sensor Suction temp. Sensor Evaporator temp. Sensor Discharge temp. Sensor MCC-818 (SUB-P.C. B) A unit A unit P.M.V.
Heronhill - for all your Toshiba requirements 9. OPERATION DESCRIPTION 9-1. Outline of Air Conditioner Control • Detection of inverter input current and current release operation This air conditioner is a capacity-variable type air • Over-current detection and prevention operation...
Page 49
Heronhill - for all your Toshiba requirements 9-2. Operation Description 9-2. 1. Basic operation ........................50 1. Operation control ....................... 50 2. Operating mode selection when performing 2-room operation .......... 51 3. Cooling/Heating operation ....................51 4. AUTO operation ......................... 52 5.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 1. Basic 1. Operation control operation Receiving the user’s operation condition setup, the operation statuses of indoor/outdoor units are controlled. 1) The operation conditions are selected by the remote controller as shown in the below.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 1. Basic 2. Operating mode selection when performing 2-room operation operation 1) The outdoor unit operating mode conforms to the instructions of the indoor unit that was pressed first.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 1. Basic 4. AUTO operation 1) Detects the room temperature (Ta) when operation the operation started. Selection of operation mode As shown in the following figure, the operation starts by...
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 2. Indoor fan <In cooling operation> motor control (This operation controls the fan speed at indoor unit side.) * Symbols The indoor fan (cross flow fan) is operated by the phase- : Ultra High control induction motor.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 2. Indoor fan <In heating operation> (Heat pump model) 1) When setting the fan speed to L, motor control L+, M, M+ or H on the remote...
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 3. Outdoor fan The blowing air volume at the outdoor unit side is controlled. 1) The operation command sent motor control from the remote controller is...
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 4. Capacity 1) Four indoor units from A to D determine the respective instruction revolutions from the differ- control ence between the remote controller setting temperature (Ts) and the indoor temperature (Ta), and transmit this to the outdoor unit.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 6. Release protective <In cooling/dry operation> 1) When temperature of the indoor control by tempera- heat exchanger drops below 5°C, (Prevent-freezing control for indoor heat exchanger)
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 7. Winding/Coil When the outdoor temperature is low, the windings/ Winding/Coil heating is performed when heating control coils are heated to ensure compressor reliability. the following conditions are met.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 9. Louver control This function controls the air direction of the indoor unit. 1) Louver • The position is automatically controlled according to the operation mode (COOL/HEAT).
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 10. ECO When pressing [ECO] button on the remote controller, a quiet operation and mild operation is performed by reducing the fan speed and the compressor speed.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 11. Temporary Pressing [RESET] button starts the temporary 1) When pressing [RESET] button, the operation operation of [AUTO] operation. When keeping [RE- temporary [AUTO] operation starts.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 12. Air purifying control [Detection of abnormality] 1. Purpose The air purifying control function is to alert the user to trouble in the ionizing or Purifying operation air purifying operation.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 14. Pulse motor This function controls throttle amount of the 1) When starting the operation, move the valve (P.M.V.) refrigerant in the refrigerating cycle. valve once until it fits to the stopper.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 15. Clean operation 1. Purpose The clean operation is to minimize the growth of mold, bacteria etc. by running the fan and drying so as to keep the inside of the air conditioner clean.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 16. Clean operation Setting the clean operation release release * J04 will be near the MCU so take Add J04 of the indoor P.C. board assembly.
Heronhill - for all your Toshiba requirements Item Operation flow and applicable data, etc. Description 17. Select switch on 1. Purpose remote controller This operation is to operate only one indoor unit using one remote controller. 2. Description Press the operation button When operating one indoor unit in a on the remote controller.
Heronhill - for all your Toshiba requirements 9-3. Auto Restart Function This indoor unit is equipped with an automatic restarting function which allows the unit to restart operating with the set operating conditions in the event of a power supply being accidentally shut down.
Heronhill - for all your Toshiba requirements 9-3-2. How to Cancel the Auto Restart Function To cancel auto restart function, proceed as follows : Repeat the setting procedure : the unit receives the signal and beeps three times. The unit will be required to be turned on with the remote controller after the main power supply is turned off.
Heronhill - for all your Toshiba requirements 9-5. Remote Controller and Its Fuctions 9-5-1. Parts Name of Remote Controller Infrared signal emitter Cancel button (CLR) Transmits signal to the indoor unit. Press this button to cancel the ON timer and OFF timer.
Heronhill - for all your Toshiba requirements 9-5-2. Name and Functions of Indications on Remote Controller [Display] All indications, except for the clock time indicator, are displayed by pressing the button. Transmission mark TIMER and clock time indicator This transmission mark...
Heronhill - for all your Toshiba requirements 9-6. Hi-POWER Mode ([Hi-POWER] button on the remote controller is pressed) When [Hi-POWER] button is pressed while the indoor unit is in Auto, Cooling or Heating operation, Hi-POWER mark is indicated on the display of the remote controller and the unit operates as follows.
Heronhill - for all your Toshiba requirements 10. INSTALLATION PROCEDURE 10-1. Safety Cautions For the rear left and left piping Hook 47 mm or more 1 Installation plate Wall Hook 140 mm or more Insert the cushion between 74 mm...
Page 73
Heronhill - for all your Toshiba requirements 10-2. Optional Parts, Accessories and Tools 10-2-1. Optional Installation Parts Part Code Parts name Q’ty Refrigerant piping Indoor unit name Liquid side (Outer diameter) Gas side (Outer diameter) 1 ea. RAS-B10GKVP-E, B13GKVP-E 6.35 mm 9.52 mm...
Page 74
Heronhill - for all your Toshiba requirements 10-2-3. Installation/Servicing Tools Changes in the product and components In the case of an air conditioner using R410A, in order to prevent any other refrigerant from being charged accidentally, the service port diameter of the outdoor unit control valve (3-way valve) has been changed.
Page 75
Heronhill - for all your Toshiba requirements 10-3. Indoor Unit 10-3-2. Drilling a Hole and Mounting Instal- lation Plate 10-3-1. Installation Place • A place which provides enough spaces around the Drilling a hole indoor unit as shown in the diagram.
Page 76
Heronhill - for all your Toshiba requirements 10-3-3. Electrical Work When the installation plate is directly mounted on the wall 1. The supply voltage must be the same as the rated voltage of the air conditioner. 1. Securely fit the installation plate onto the wall by 2.
Page 77
Heronhill - for all your Toshiba requirements 10-3-5. Piping and Drain Hose Installation CAUTION Piping and drain hose forming • Be sure to refer to the wiring system diagram labeled inside the front panel. • Since condensation results in machine trouble, •...
Page 78
Heronhill - for all your Toshiba requirements How to attach the drain cap In case of bottom right or bottom left piping 1. Insert hexagonal wrench (4 mm). • After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool.
Page 79
Heronhill - for all your Toshiba requirements 10-3-7. Drainage CAUTION 1. Run the drain hose at a downward sloped angle. • Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. NOTE : In case of leftward piping and rear-leftward •...
Page 80
Heronhill - for all your Toshiba requirements 10-4. Outdoor Unit CAUTION 10-4-1. Accessory and Installation Parts 1. Install the outdoor unit without anything blocking the air discharging. 2. When the outdoor unit is installed in a place exposed always to a strong wind like a coast ...
Page 81
Heronhill - for all your Toshiba requirements 10-4-5. Refrigerant Piping Connection • Flaring size : A (Unit : mm) CAUTION Fig. 10-4-4 KEEP IMPORTANT 4 POINTS FOR PIPING WORK - 0.4 Outer dia. of copper pipe 1. Keep dust and moisture from entering the R410A pipes.
Page 82
Heronhill - for all your Toshiba requirements 1. Piping connections to the outdoor unit should be Tightening connection arranged in the sequence A, B, C, D starting from the bottom. Align the centers of the connecting pipes and tighten (For each piping connection, the gas pipe is on the the flare nut as far as possible with your fingers.
Page 83
Heronhill - for all your Toshiba requirements 10-4-7. Evacuating Packed valve handling precautions After the piping has been connected to all indoor • Open the valve stem all the way out ; do not try to unit(s), you can perform the air purge together at once.
Page 84
Heronhill - for all your Toshiba requirements 3 units (A + B + C) Multi 10-4-9. Check and Test Operation Terminal block (Connecting cable) For R410A, use the leak detector exclusively manufactured for HFC refrigerant (R410A, R134a, etc.). * The conventional leak detector for HCFC refriger- Screw ant (R22, etc.) cannot be used because its sensi-...
Page 85
Heronhill - for all your Toshiba requirements 10-4-10. Miswiring (Mispiping) Check 5. During check (Check time 3 to 20 minutes). • When an error describes in the table below Make sure that the wiring and piping for each room occurred check operation stops and error code have the same alphabetical codes (A, B, C, D).
Page 86
Heronhill - for all your Toshiba requirements Useful Functions Self-Diagnosis by LED Indication • For this outdoor unit, the self-diagnosis is possible by using five LEDs (1 Yellow + 4 Red). * LEDs (D800 to D804) are provided on P.C. board of the inverter.
Heronhill - for all your Toshiba requirements 11. HOW TO DIAGNOSE THE TROUBLE The pulse modulating circuits are mounted to both indoor and outdoor units. Therefore, diagnose troubles according to the trouble diagnosis procedure as described below. (Refer to the check points in servicing written on the wiring diagrams attached to the indoor/outdoor units.)
Page 88
Heronhill - for all your Toshiba requirements 11-1. First Confirmation 11-1-3. Operation Which is not a Trouble (Program Operation) 11-1-1. Confirmation of Power Supply For controlling the air conditioner, the program Confirm that the power breaker operates (ON) operations are built in the microcomputer as de- normally.
Page 89
Heronhill - for all your Toshiba requirements 11-3. Self-Diagnosis by Remote Controller (Check Code) 1. If the lamps are indicated as shown B to E in Table 11-3-1, execute the self-diagnosis by the remote controller. 2. When the remote controller is set to the service mode, the indoor controller diagnoses the operation condi- tion and indicates the information of the self-diagnosis on the display of the remote controller with the check codes.
Page 90
Heronhill - for all your Toshiba requirements 11-3-2. Caution at Servicing 1. After servicing, press the START/STOP button to return to the normal mode. 2. After servicing by the check code, turn off breaker of the power supply, and turn on breaker of the power supply again so that memory in the microcomputer returns the initial status.
Page 91
Heronhill - for all your Toshiba requirements Block distinction Operation of diagnosis function Judgment and action Check Check Block Cause of operation conditioner Remarks code code status Outdoor P.C. Inverter over-current All off Displayed when Even if trying operation again, all...
Heronhill - for all your Toshiba requirements 11-4. Judgment of Trouble by Every Symptom 11-4-1. Indoor Unit (Including Remote Controller) (1) Power is not turned on (Does not operate entirely) <Primary check> 1. Is the supply voltage normal? 2. Is the normal voltage provided to the outdoor unit? 3.
Page 93
Heronhill - for all your Toshiba requirements (3) Only the indoor motor fan does not operate <Primary check> 1. Is it possible to detect the power supply voltage (AC220–240V) between on the terminal block? 2. Does the indoor fan motor operate in cooling operation? (In heating operation, the indoor fan motor does not operate for approximately 10 minutes after it is turned on, to prevent a cold air from blowing in.)
Page 94
Heronhill - for all your Toshiba requirements (4) Indoor fan motor automatically starts to rotate by turning on power supply <Cause> The IC is built in the indoor fan motor. Therefore the P.C. board is also mounted to inside of the motor.
Page 95
Heronhill - for all your Toshiba requirements (5) Troubleshooting for remote controller <Primary check> Check that A or B selected on the main unit is matched with A or B selected on the remote controller. The unit does not beep at all.
Page 96
Heronhill - for all your Toshiba requirements 11-4-2. Wiring Failure (Interconnecting and Serial Signal Wire) (1) Outdoor unit does not operate 1) Is the voltage between of the indoor terminal block varied? Confirm that transmission from indoor unit to outdoor unit is correctly performed based upon the follow- ing diagram.
Page 97
Heronhill - for all your Toshiba requirements 11-5. Trouble Diagnosis by Outdoor LED For the outdoor unit, the self-diagnosis is possible by LED (Yel) and four LEDs (Red). • LED (Yel) (D800) and LEDs (Red) (D801 to D804) are D800 D801 D802 D803 D804...
Heronhill - for all your Toshiba requirements 11-6. Troubleshooting 11-6-1. How to Check Whether the Air Purifier is Good or Not Turn off the power breaker once, and turn on again after 10 seconds. Does the OPERATION indicator flash? To item “Power supply is not turned on”...
Page 99
Heronhill - for all your Toshiba requirements 11-6-2. How to Check Whether the Minus Ion Generator is Good or Not Turn off the power breaker once, and turn on again after 10 seconds. Does the OPERATION indicator flash? To item “Power supply is not turned on”...
Heronhill - for all your Toshiba requirements 11-7. How to Diagnose Trouble in Outdoor Unit 11-7-1. Summarized Inner Diagnosis of Inverter Assembly Table 11-7-1 Diagnosis/Process flowchart Item Contents Summary Preparation Turn “OFF” the power supply breaker, and remove 3P connector which connects Remove inverter and compressor.
Page 101
Heronhill - for all your Toshiba requirements Diagnosis/Process flowchart Item Contents Summary Check Check winding resistance between phases of compres- sor, and resistance between outdoor frames by using a tester. Check → OK if 10MΩ or more • Is not grounded.
Page 102
Heronhill - for all your Toshiba requirements (3) Check procedures Table 11-8-1 Procedure Check points Causes Turn off the power supply breaker Check whether or not the fuse (F01) Impulse voltage was applied or the and remove the P.C. board is blown.
Page 103
Heronhill - for all your Toshiba requirements 11-8-2. P.C. Board Layout +12V [1] Sensor characteristic table TD : Discharge temp. sensor TA : Room temp. sensor TC : Heat exchanger temp. sensor TO : Outdoor temp. sensor TE : Outdoor heat exchanger temp. sensor TS : Suction temp.
Page 104
Heronhill - for all your Toshiba requirements 11-8-3. Indoor Unit (Other Parts) Part name Checking procedure Room temp. (TA) sensor Disconnect the connector and measure the resistance value with tester. Heat exchanger (TC) sensor (Normal temp.) Temperature 10°C 20°C 25°C 30°C...
Page 105
Heronhill - for all your Toshiba requirements 11-8-5. Checking Method for Each Part Part name Checking procedure Electrolytic capacitor 1. Turn OFF the power supply breaker. (For raising pressure, 2. Discharge all three capacitors completely. smoothing) 3. Check that safety valve at the bottom of capacitor is not broken.
Page 106
Heronhill - for all your Toshiba requirements 11-9. How to Simply Judge Whether Outdoor Fan Motor is Good or Bad 1. Symptom • Outdoor fan motor does not rotate. • Outdoor fan motor stops within several tens seconds though it started rotating.
Heronhill - for all your Toshiba requirements 12. HOW TO REPLACE THE MAIN PARTS WARNING • Since high voltages pass through the electrical parts, turn off the power without fail before proceeding with the repairs. Electric shocks may occur if the power plug is not disconnected.
Page 108
Heronhill - for all your Toshiba requirements Part name Procedures Remarks Front panel 4) Press “ ” part under the front panel and remove hooks of the front panel from the installation plate. Pull here Installation plate Press here Press here...
Page 109
Heronhill - for all your Toshiba requirements Part name Procedures Remarks High voltage 1) Follow to the procedure in the item generator 2) Remove the drain guide. 3) To remove the air ionizer from the back body, pull it toward you while pressing down on its left Connector and right claws.
Page 110
Heronhill - for all your Toshiba requirements Part name Procedures Remarks Electric parts 1) Follow the procedure up to 4) in above. box assembly 2) Remove screw of earth lead attached to the Lead wire end plate of the evaporator.
Page 111
Heronhill - for all your Toshiba requirements Part name Procedures Remarks Horizontal louver 1) Remove shaft of the horizontal louver from the back body. (First remove the left shaft, and then remove other shafts while sliding the horizontal louver leftward.)
Page 112
Heronhill - for all your Toshiba requirements Part name Procedures Remarks Bearing 1) Follow to the procedure in the items 2) Remove the two fixing screws used to secure the left edge panel of the heat exchanger, and Screw remove the two screws used to secure the Bearing bearing base.
Page 113
Heronhill - for all your Toshiba requirements Part name Procedures Remarks Fan motor 1) Follow to the procedure in the item 2) Loosen the set screw of the cross flow fan. 3) Remove two fixing screws of the motor band (Right), and then remove the motor band (Right).
Page 114
Heronhill - for all your Toshiba requirements Part name Procedures Remarks Cross flow fan <Caution at reassembling> 1) At assembling work of the bearing base, check that the drain pipe is surely incorpo- rated in the back body. (Otherwise, water leak is caused.)
Page 115
Heronhill - for all your Toshiba requirements 12-2. Microcomputer Part name Procedure Remarks Common procedure 1) Turn the power supply off to stop the Replace terminal block, operation of air-conditioner. microcomputer ass’y and the P .C. board ass’y. 2) Remove the front panel.
Page 116
Heronhill - for all your Toshiba requirements 12-3. Outdoor Unit Part name Procedure Remarks Common 1. Detachment procedure 1) Stop operation of the air conditioner, and turn “OFF” the power breaker. Air outlet panel Upper panel 2) Remove the side panel. (Ø4 × 10L 3 pcs.)
Page 117
Heronhill - for all your Toshiba requirements Part name Procedure Remarks Control 1. Disconnect lead wires and connectors connected from the control board assembly to other parts. board assembly 1) Lead wires • Connection with terminal block : 7 wires...
Page 118
Heronhill - for all your Toshiba requirements Part name Procedure Remarks Fan motor 1) Perform work from item 1) to 5), 7) of 2) Remove the flange nut fixing the fan motor and the propeller fan. • Flange nut is loosened by turning clockwise.
Page 119
Heronhill - for all your Toshiba requirements Part name Procedure Remarks Pulse motor 1. Detachment valve coil 1) Perform work of item Positioning bracket at coil side PMV coil 2) Release the coil from the notch by turning it, Lead wire and remove coil from the pulse motor valve.
Page 120
Heronhill - for all your Toshiba requirements Part name Procedure Remarks Replacement of 1) Cut the sensor 100 mm longer than old temperature sensor one. Cutting here Thermal for servicing only Connector sensor part 2) Cut the protective tube after pulling out it (200 mm).
Page 121
Heronhill - for all your Toshiba requirements <MCC-1438> – 121 – Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807...
Page 122
Heronhill - for all your Toshiba requirements <MCC-818> – 122 – Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807...
Heronhill - for all your Toshiba requirements 13. EXPLODED VIEWS AND PARTS LIST 13-1. Indoor Unit (1) 225, 226 221, 222, 224 218, 219 ∗ The parts in the following parts list are conformed to RoHS. Therefore be sure to use the following parts for repairing and replacing.
Page 124
Heronhill - for all your Toshiba requirements Indoor Unit (2) 407, 408, 409 ∗ The parts in the following parts list are conformed to RoHS. Therefore be sure to use the following parts for repairing and replacing. Location Part Location...
Page 125
Heronhill - for all your Toshiba requirements 13-2. Outdoor Unit 41, 42 39, 40 12, 45, 47 13, 46, 48 49 27 50, 51 – 125 – Tel: 01823 665660 www.heronhill.co.uk Fax: 01823 665807...
Page 126
Heronhill - for all your Toshiba requirements ∗ The parts in the following parts list are conformed to RoHS. Therefore be sure to use the following parts for repairing and replacing. Location Part Location Part Description Description 43005640 Cabinet, Back Ass’y...
Page 127
Heronhill - for all your Toshiba requirements 13-3. P.C. Board Layout RAS-4M27GAV-E TO Sensor TE Sensor TS Sensor TD Sensor TGa Sensor TGb Sensor TGc Sensor TGd Sensor ∗ The parts in the following parts list are conformed to RoHS.
Page 128
Heronhill - for all your Toshiba requirements RAS-4M27GACV-E TO Sensor TD Sensor TGa Sensor TGb Sensor TGc Sensor TGd Sensor ∗ The parts in the following parts list are conformed to RoHS. Therefore be sure to use the following parts for repairing and replacing.
Page 129
Heronhill - for all your Toshiba requirements RAS-3M26GAV-E TO Sensor TE Sensor TS Sensor TD Sensor TGa Sensor TGb Sensor TGc Sensor ∗ The parts in the following parts list are conformed to RoHS. Therefore be sure to use the following parts for repairing and replacing.