11. OPTIONS AND PERIPHERAL EQUIPMENT
11.2 Regenerative options
CAUTION
11.2.1 Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
(1) 200 V class
Servo
Built-in
MR-RB032
amplifier
regenerative
resistor
MR-J4-10B
(-RJ)
MR-J4-20B
10
(-RJ)
MR-J4-40B
10
(-RJ)
MR-J4-60B
10
(-RJ)
MR-J4-70B
20
(-RJ)
MR-J4-100B
20
(-RJ)
MR-J4-200B
100
(-RJ)
MR-J4-350B
100
(-RJ)
MR-J4-500B
130
(-RJ)
MR-J4-700B
170
(-RJ)
Servo
External regenerative
amplifier
resistor (accessory)
MR-J4-11KB
500 (800)
(-RJ)
MR-J4-15KB
850 (1300)
(-RJ)
MR-J4-22KB
850 (1300)
(-RJ)
Note 1. Always install a cooling fan.
2. Values in parentheses assume the installation of a cooling fan.
Do not use servo amplifiers with regenerative options other than the combinations
specified below.
Otherwise, it may cause a fire.
MR-RB12
MR-RB30
[40 Ω]
[40 Ω]
[13 Ω]
30
30
100
30
100
30
100
30
100
30
100
300
(Note 2) Regenerative power [W]
MR-RB5R
MR-RB9F
[3.2 Ω]
[3 Ω]
500
(800)
850
(1300)
Regenerative power [W]
MR-RB3N
MR-RB31
MR-RB32
[9 Ω]
[6.7 Ω]
[40 Ω]
300
300
300
MR-RB9T
[2.5 Ω]
850
(1300)
11 - 10
(Note 1)
(Note 1)
MR-RB50
MR-RB5N
[13 Ω]
[9 Ω]
300
300
500
500
(Note 1)
MR-RB51
[6.7 Ω]
500
500