KIV-700/BT900 COMPONENTS DESCRIPTION ● SWITCH UNIT (X16-6880-10) Ref. No. Application / Function Operation / Condition / Compatibility Remote Controller Outputs remote control signal when IR signal is received. Triangle RED Driver When the base turns on, D1 is turned on.
Page 4
KIV-700/BT900 COMPONENTS DESCRIPTION Ref. No. Application / Function Operation / Condition / Compatibility IC303 Mute Logic Controls logic for muting. IC304 Reset Logic Logic for reset (SRC/MENU/AUDIO). IC451 E-VOL & Source Selector Controls the source and volume. IC500 RDS Decoder RDBS and RDS decoder.
SRC KEY Source key input H: OFF, L: ON MENU KEY Menu key input H: OFF, L: ON KENWOOD KEY KENWOOD key (Rotary push) input H: OFF, L: ON 24,25 Not used Output L fi xed PWIC BEEP Beep output...
Page 6
ACC found: L, No ACC: H ILLUMI DET Dimmer illumination detection L: ON, H: OFF VCC2 Not used Output L fi xed KIV-700 TEL mute: Below 1V, NAVI LINE MUTE Line mute detection mute: Over 2.5V KIV-BT900 NAVI mute: Over 2.5V DSP PDN DSP reset...
Page 7
KIV-700/BT900 MICROCOMPUTER’S TERMINAL DESCRIPTION Truth Pin No. Pin Name Application Processing / Operation / Description Value Table SDA EVOL SDA I/O Data output from system u-com to E-VOL SCL DSP SCL I/O I2C clock for DSP SCL E2P SCL I/O I2C clock for the mother E2PROM SCL EVOL SCL I/O Clock output from system μ-com to E-VOL...
Page 8
KIV-700/BT900 MICROCOMPUTER’S TERMINAL DESCRIPTION Truth value table q FSEL terminal switch (AM) [FSEL_5V] Pin36 μ-com terminal 1110kHz~1700kHz 530kHz~1100kHz Reception frequency (Destination “K”) 1107kHz~1611kHz 531kHz~1098kHz Channel space switching 1107kHz~1611kHz 531kHz~1098kHz Reception frequency (Destination “M” & “E”) 1110kHz~1700kHz 530kHz~1100kHz Channel space switching Reception frequency (Destination “J”)
KIV-700/BT900 TEST MODE ■ Key layout ∗ The product can be reset by simultaneously pressing the following three keys: [MENU], [AUD] and [SRC]. MENU DISP SEARCH MODE Play/Pause TEL or TI or PLAY MODE ■ How to transfer into the test mode Press and hold the [TEL] or [TI] or [PLAY MODE] and [FAV] keys and reset.
Page 10
KIV-700/BT900 TEST MODE ■ Information display while all the lights are turned on The following information shall be displayed when the key listed in the next table is pressed while all the lights are turned on in STANDBY source. Press this key briefl y: To transfer to Software version & various service information display mode.
Page 11
[DISP] S Y S _ R O M _ R 1 2 3 ∗ Press this Ex. In the case of the model without the built-in BT (KIV-700) key briefl y S Y S 0 2 – 1 . 2...
Page 12
KIV-700/BT900 TEST MODE • POWER ON time display · Image of display P o n T i m _ 0 H x x _ x x x x x (Remote (In the “xx”, the fi gure between 00 and 50 (00~50) shall be displayed. When it is less than 1 hour, it shall be dis- controller) played rounded up/down to 10 minutes.)
Page 13
KIV-700/BT900 TEST MODE Only in E type, switch frequency to LW-216kHz by pressing [2] key or [FAV] key briefl y in TUNER AM band. In the model for all destinations, switch Band by pressing [SEARCH MODE] key briefl y in TUNER source.
Page 14
KIV-700/BT900 TEST MODE Seek stop level manual adjustment mode • Image of display (In the case of Normal [Local OFF]) M N N _ 3 . 9 8 V (In the case of Local [Local ON]) M N L _ 4 . 4 4 V The value saved in E2PROM as the default value is displayed.
Page 15
KIV-700/BT900 TEST MODE ■ BT mode test mode (KIV-BT900) The internal LOOPBACK function is available only in the model with the built-in BT. ∗ After switching into the BT mode (BT SRC) with TEL, follow the next steps of operations: Press and hold this key: To enter the internal LOOPBACK mode ∗...
Page 16
KIV-700/BT900 TEST MODE ■ Menu list adjust mode Press [MENU] key briefl y to display the Menu list. Press [DNPP/SBF] and [DIRECT] key on the remote controller to transfer into the Menu list mode. You shall not use the remote controller to successively send the items.
Page 17
KIV-700/BT900 TEST MODE ■ ROM correction (system μ-com) update functional specifi cation While keeping pressing [SEARCH MODE] and [Play/Pause] keys, operate reset and BU ON to transfer into this mode. Procedure Display Description Reset and BU ON operation (Display lights up)
Page 18
KIV-700/BT900 INSTALLER MEMORY SPECIFICATIONS At specialists (or specialty stores), when the installer sends source in which the saving operation was carried out is the vehicle back to the user, they may make the store-rec- saved as such.) ommended audio confi guration.
Page 19
KIV-700/BT900 PC BOARD PC BOARD (COMPONENT SIDE VIEW) (FOIL SIDE VIEW) SWITCH UNIT SWITCH UNIT X16-6880-10 (J76-0698-02) X16-6880-10 (J76-0698-02) TP18 TP19 TP13 TP12 TP11 TP16 TP15 TP14 TP17 TP25 TP21 TP23 TP20 TP24 TP22 TP26 TP27 TP10 TP28 TP29 D14 D13...
KIV-700/BT900 PC BOARD (COMPONENT SIDE VIEW) ELECTRIC UNIT X34-677x-xx A/2 (J76-0699-12) J400 AUX OUT IC201 PRE OUT 13 11 12 8 4 3 J470 9 10 6 J420 C225 C227 R205 C474 R472 D209 C206 C226 R476 C224 D201 R474...
Page 29
• DC voltages are as measured with a high impedance volt me ter. Val ues may vary slight ly due to vari a tions between in di vid u al in- stru ments or/and units. KIV-700/BT900 (1/4) X34-677x-xx A/2 (4/4)
Page 30
FREQ of IC700 TP702 KIV-700/BT900 (2/4) CAUTION : For continued safety, re place safe ty critical com po nents only with manufacturer’s rec om mend ed parts (refer to parts list). Indicates safety critical com po nents. To reduce the risk of electric shock, leakage-cur rent or re sis tance mea sure ments shall be carried out (ex posed parts are ac cept ably in su lat ed from the supply cir cuit) be fore the ap pli ance is returned to the customer.
Page 35
CN72 : DA204U : FTZ6.8E KIV-700/BT900 (4/4) D16-18 : UDZW6.8(B) CAUTION : For continued safety, re place safe ty critical com po nents only with manufacturer’s rec om mend ed parts (refer to parts list). Indicates safety critical com po nents. To reduce the risk of electric shock, leakage-cur rent or re sis tance mea sure ments shall be car- ried out (ex posed parts are ac cept ably in su lat ed from the supply cir cuit) be fore the ap pli ance is returned to the customer.
KIV-700/BT900 EXPLODED VIEW 291 (X34-:ELECTRIC UNIT) On bottom of IC700 there is a soldering part. Therefore replacement of IC700 is impossible. When needing replacement of IC700, “291” can be replaced. (X34-) IC700 (X34-) (B/2) : N09-6492-05 (X17-) : N09-6758-05 (X17-)
3A ✽ K28-0422-14 KNOB ASSY (KENWOOD) W1 -9 R92-2053-05 CHIP R 0 OHM J 1/8W K: KIV-BT900 K1: KIV-700 M1: KIV-700 E1: KIV-700 Indicates safety critical com po nents. K : North America M : Other Areas) (E : Europe...
Page 38
CHIP R J 1/16W C401 CK73GB1H104K CHIP C 0.10UF R301 RK73GB2A300J CHIP R J 1/10W K: KIV-BT900 K1: KIV-700 M1: KIV-700 E1: KIV-700 Indicates safety critical com po nents. K : North America M : Other Areas) (E : Europe...
Page 39
10UF C335 CK73GB1H104K CHIP C 0.10UF C90-6851-05 ELECTRO 220UF 25WV C336,337 CK73GB0J475K CHIP C 4.7UF K: KIV-BT900 K1: KIV-700 M1: KIV-700 E1: KIV-700 Indicates safety critical com po nents. K : North America M : Other Areas) (E : Europe...
Page 40
CHIP R 4.3K J 1/10W C754 CC73GCH1H101J CHIP C 100PF RK73GB2A562J CHIP R 5.6K J 1/10W K: KIV-BT900 K1: KIV-700 M1: KIV-700 E1: KIV-700 Indicates safety critical com po nents. K : North America M : Other Areas) (E : Europe...
Page 41
J 1/10W R333 RK73GB2A104J CHIP R 100K J 1/10W R553,554 RK73GB2A104J CHIP R 100K J 1/10W K: KIV-BT900 K1: KIV-700 M1: KIV-700 E1: KIV-700 Indicates safety critical com po nents. K : North America M : Other Areas) (E : Europe...
Page 42
RKZ6.8KG(B2) ZENER DIODE Q366 RT1N144M-T111 TRANSISTOR D441 MC2846-T111 DIODE Q440 RT1N430M-T111 TRANSISTOR Q441 RT1P241M-T111 TRANSISTOR K: KIV-BT900 K1: KIV-700 M1: KIV-700 E1: KIV-700 Indicates safety critical com po nents. K : North America M : Other Areas) (E : Europe...
Page 43
POSITIVE RESISTOR A900 W02-5374-05 ELECTRIC CIRCUIT MODULE A480 X86-4032-70 FRONT-END UNIT A480 X86-4230-11 FRONT-END UNIT KK1M1 K: KIV-BT900 K1: KIV-700 M1: KIV-700 E1: KIV-700 Indicates safety critical com po nents. K : North America M : Other Areas) (E : Europe...
Weight ............2.6 lbs (1.20kg) Output power ..+4dBm (MAX), 0dBm (AVE), Power Class 2 Maximum communication range KENWOOD follows a policy of continuous advancements ........Line of sight approx. 10m (32.8ft) in development. For this reason specifications may be Profi le ..........HFP (Hands Free Profi le), changed without notice.