Chapter 2. Installing and configuring the switch

You can install the SAN42B-R switch in the following ways:
v As a stand-alone unit on a flat surface. For instructions and more information,
v In an Electronic Industries Association (EIA) cabinet using the fixed rack mount
Use the following information to complete the installation and configuration.
v "Site preparation and installation requirements"
v "Items included with the switch" on page 9
v "Setting up the switch as a standalone unit" on page 10
v "Installing in an EIA cabinet" on page 10
v "Initial setup of the switch" on page 21
Attention: Read the "Safety notices and labels" on page xi before attempting any
installation, maintenance, or service procedures.

Site preparation and installation requirements

The following conditions are required to ensure correct installation and operation
of the switch.
Attention: Follow ESD precautions whenever handling the switch or components.
See "ESD precautions" on page xvii.
Electrical requirements
For successful installation and operation of the switch, ensure that the following
electrical requirements are met:
v The primary outlet is correctly wired, protected by a circuit breaker, and
v It is best practice that each power supply obtain its power from a different
v The supply circuit, line fusing, and wire size are adequate, as specified by the
v The power supply standards are met. See "Power supply specifications" on page
Environmental considerations
For successful installation and operation of the switch, ensure that the following
environmental requirements are met:
v At a minimum, adequate cooling requires that you install the switch with the
© Copyright IBM Corp. 2014
see "Setting up the switch as a standalone unit" on page 10.
kit. For more information, see "Installing in an EIA cabinet" on page 10.
grounded in accordance with local electrical codes.
protected and wired source.
electrical rating on the switch nameplate.
52.
Attention: To maximize fault tolerance, connect each power cord to a separate
power source.
intake side (non port side), facing the cool-air aisle.
7