Troubleshooting
8.3 Alarm list web server
ID
Severity
50
MR
51
MD
52
F
53
F
54
F
55
F
56
F
57
F
58
F
59
F
60
F
91
MR
93
F
94
F
96
F
97
F
65
N
14
F
15
MD
16
MR
28
MR
29
MR
30
N
31
MR
32
N
33
N
278
Event
Unexpected module type detected.
Module with reduced power de-
tected.
Incompatible module detected
Unexpected empty slot detected.
Unknown module found (slot 1).
Unknown module found (slot 2).
Unknown module found (slot 3).
Unknown module found (slot 4).
Unknown module found (slot 5).
Unknown module found (slot 6).
Unknown module found.
Shutdown due to system overload.
System safety shutdown due to
critical load difference between AC
input and outputs.
System safety shutdown due to
significant load difference between
AC input and outputs.
Ready for restart after critical load
condition.
Ready for restart after out of profile
peak load.
Parameter out of permissible value
range.
Overload shutdown of the output.
Overload detected at the output.
The actual value of the output
current is above the set advance
warning threshold.
Output is ready to be switched on.
Current limit on the output after
occurrence of an overload.
Output was switched off manually.
Output switched off during buffer-
ing
Output was switched off.
Output was switched on.
Help text
Unexpected module type detected.
A module with reduced power was detected. Deviating sys-
tem behavior may be possible.
The module has a module type that is incompatible with the
configuration. The module cannot be commissioned.
Unexpected empty slot detected.
Unknown module found (slot 1).
Unknown module found (slot 2).
Unknown module found (slot 3).
Unknown module found (slot 4).
Unknown module found (slot 5).
Unknown module found (slot 6).
Unknown module found.
System load current is outside the permissible overload
profile.
Critical load difference between the AC input and the out-
puts. The initiated safety shutdown will turn off the device
immediately.
Out of range difference between AC input and outputs. Turn
power off and on to reactivate the system.
Ready for restart after safety shutdown because of critical
load current. Turn power off and on to reactivate the system.
Ready for restart after safety shutdown because out of pro-
file peak load.
A control command is attempting to set a value outside the
value range that the hardware module can implement. The
value is automatically limited to the minimum or maximum
permitted value for the module.
Invalid overload occurred at the output. The output was
switched off.
Output current at the output is above the preset response
threshold but is still within the permissible overload profile.
The output current is about to be limited.
The actual value of the output current is above the config-
ured advance warning threshold and is below the
response threshold.
Output is ready to be switched on again after automatic
overload shutdown.
Output is in overload mode. The output current is limited to
the configured response threshold.
Output was switched off manually directly on the device.
Output switched off during buffering
Output was switched off.
Output was switched on.
Power supply system PSU8600
Manual, 05.2017, A5E36758446-3-76