Chapter 5
Setup and Configuration
10
Figure 169: 802.1X Parameters Form
1. Port Box
2. tX Period Box
7. suppTimeout Box
3.
Configure the following parameter(s) as required:
Parameter
Port
txPeriod
quietPeriod
reAuthEnabled
reAuthPeriod
reAuthMax
suppTimeout
222
3. quietPeriod Box
8. serverTimeout Box
9. maxReq Box
Description
Synopsis: 1 to maximum port number
Default: 1
The port number as seen on the front plate silkscreen of the switch.
Synopsis: 1 to 65535
Default: 30 s
The time to wait for the Supplicant's EAP Response/Identity packet before retransmitting
an EAP Request/Identity packet.
Synopsis: 0 to 65535
Default: 60 s
The period of time not to attempt to acquire a Supplicant after the authorization session
failed.
Synopsis: { No, Yes }
Default: No
Enables or disables periodic re-authentication.
Synopsis: 60 to 86400
Default: 3600 s
The time between periodic re-authentication of the Supplicant.
Synopsis: 1 to 10
Default: 2
The number of re-authentication attempts that are permitted before the port becomes
unauthorized.
Synopsis: 1 to 300
Default: 30 s
The time to wait for the Supplicant's response to the authentication server's EAP packet.
4. reAuthEnabled Options
5. reAuthPeriod Box
10. Apply Button
6. reAuthMax Box
11. Reload Button