Bosch Tronic 1000T ES 30 User And Installation Manual

Bosch Tronic 1000T ES 30 User And Installation Manual

Electrical storage water tank tronic 1000t series; tronic 2000t
Hide thumbs Also See for Tronic 1000T ES 30:

Advertisement

6720817966-00.1V
Electrical storage water tank
Tronic 1000T / 2000T
ES 030/050/080/100/120 6...
User and Installation manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Tronic 1000T ES 30

  • Page 1 6720817966-00.1V Electrical storage water tank Tronic 1000T / 2000T ES 030/050/080/100/120 6... User and Installation manual...
  • Page 2: Table Of Contents

    2 | Index Index 8.1.3 Safety valve ......15 Key to symbols and safety instructions ..3 8.1.4 Maintenance and repair .
  • Page 3: Key To Symbols And Safety Instructions

    Key to symbols and safety instructions | 3 ▶ During the installation isolate the appliance from the power Key to symbols and safety instructions supply. Installation and conversion Key to symbols ▶ Only permit an authorised service to install this appliance. Warnings ▶...
  • Page 4: Technical Characteristics And Dimensions

    Using the appliance for any other purpose will be considered completely neutral with regards to compatibility and contact incorrect use. Bosch accepts no liability for any damage with potable water. This lining is neutral with regard to the use resulting from such use.
  • Page 5: Specification

    Technical Characteristics and dimensions | 5 Specification This appliance meets the requirements specified by the European Directives 2014/35/UE and 2014/30/UE. Technical characteristics Unit ES 030.V ES 030.S ES 050.V ES 050.S ES 050.H ES 080.V General characteristics Capacity Weight (empty) 11,5 12,5 15,0...
  • Page 6: Product Data On Energy Consumption

    6 | Technical Characteristics and dimensions Technical characteristics Unit ES 080.S ES 080.H ES 100.V ES 100.H ES 120.V Water temperature Temperature ranges °C until 65 °C Table 5 Technical characteristics Product data on energy consumption The following product data complies with the requirements of EU Regulations 811/2013, 812/2013, 813/2013 and 814/2013 as supplement to the Directive 2010/30/EU.
  • Page 7 Technical Characteristics and dimensions | 7 Product data Product type – – Emissions of nitrogen oxides mg/kWh Sound power level, indoors dB(A) Declared load profile – – Water heating energy efficiency class – –  Water heating energy efficiency Annual electricity consumption 1 440 2 792 1 441...
  • Page 8 8 | Technical Characteristics and dimensions Product data Daily electricity consumption (average 6,678 12,880 12,545 12,792 2,673 6,559 12,716 elec climate conditions) Annual fuel consumption Daily fuel consumption fuel Smart control enabled? – – Mixed water T= 40 °C Storage volume Thermostat temperature (factory setting) °C Indication about ability working only...
  • Page 9: Dimensions

    Technical Characteristics and dimensions | 9 Dimensions ½" 6720817966-01.1V Fig. 2 Dimensions in mm (Vertical installation) Appliance ES030... ES030.S... ES050... ES050.S... ES080... ES080.S... 1236 1036 1013 ES100... 1031 ES120... 1194 Table 9 Appliance ES050... min. 250 ES080... ES100... Table 10 min.
  • Page 10: Appliance Layout

    10 | Regulations Appliance layout Transport ▶ Do not drop the appliance. ▶ Remove the appliance from the packaging only at the place of installation. Transport, storage • The equipment should be stored in protected areas against negative temperatures. Installation Installation, power connection and commissioning must only be carried out by a service approved for such work by the local...
  • Page 11: Wall Mounting

    Installation | 11 • Never install the appliance in rooms where the ambient Vertical installation temperature can fall below 0 °C. • If the appliance is to be fitted in a room or location where the ambient temperature is higher than 35°C, provide sufficient ventilation.
  • Page 12: Water Connection

    12 | Installation Water connection ▶ Use the appropriate connection accessories to do the hydraulic connection to the appliance. CAUTION: Damage to appliance connections through contact corrosion! ▶ Use galvanic isolators in your water connections. These will avoid galvanic electric currents between the hydraulic link metals and, consequently corrosion of these.
  • Page 13: Electrical Connections

    Use | 13 If the pressure at the cold water inlet is superior to that of 80% of the maximum pressure of the appliance at, ie: 6,4 bar: ▶ Install a reducing valve (Fig. 10). The safety valve will trigger every time the water pressure in the appliance exceeds 8 bar (...
  • Page 14: Emptying The Appliance

    Manual activation of the safety valve Environment / disposal Environmental protection is a fundamental corporate strategy of the Bosch Group. The quality of our products, their efficiency and environmental safety are all of equal importance to us and all environmental protection legislation and regulations are strictly observed.
  • Page 15: Inspection/Maintenance

    Inspection/Maintenance | 15 Inspection/Maintenance CAUTION: Damages to the glass enamel! Never clean the enamel interior of the appliance with decalcifying agents. The Maintenance must only be carried out by an magnesium anode ensures anti corrosion authorized technician. protection. There is no need for alternative products for the protection of the enamel.
  • Page 16: Periodic Cleaning

    16 | Inspection/Maintenance ▶ Switch off the electric current to the appliance. ▶ Drain the appliance completely. ▶ Fill the appliance until the water comes out from all the hot water taps. ▶ Turn on the appliance to the electric current. Safety thermostat The appliance is equipped with an automatic safety thermostat.
  • Page 17: Problems

    Problems | 17 Problems Problem/Cause/Solution In the following diagram there are some solutions described for DANGER: possible problems / troubleshooting (these should only be Assembly, maintenance and repairs should performed by authorized technicians). only be carried out by authorized technicians. Problem Cause Solution...
  • Page 18: Quick Guide

    18 | Quick guide Quick guide 6 720 818 420 (2016/09) Tronic 1000T / 2000T...
  • Page 19 | 19 Notes Tronic 1000T / 2000T 6 720 818 420 (2016/09)
  • Page 20 Bosch Thermotechnik GmbH Junkersstrasse 20-24 D-73249 Wernau www.bosch-thermotechnology.com...

Table of Contents