GE MDS Mercury Series Setup Manual
Hide thumbs Also See for MDS Mercury Series:

Advertisement

Quick Links

1.0
INTRODUCTION
MDS Mercury
TM
Series transceivers provide an easy-to-install
wireless network service with long range and secure operation at
adaptive data rates approaching 30 Mbps. The transceiver is
designed for demanding applications in industrial environments,
where reliability and range are paramount.
The transceiver comes in two primary models—Base Station (BS)
and Subscriber Unit (SU), each with unique hardware profiles.
Both models support Ethernet and serial services. A BS is a wire-
less switch that usually provides connectivity into a wired Ethernet
LAN/WAN.
Subscriber Units associate over the air with a BS and are typically
connected to an Ethernet or Serial device via a local cable. The
outward appearance of the standard SU is very similar to the BS.
NOTE: To determine whether a unit is an BS or Subscriber Unit,
check the dome label on the top of the unit.
Refer to the Mercury Series Technical Manual (05-6302A01) for
advanced procedures and additional information.
1.1
Connectors & Indicators
Figure 1
shows the connectors and indicators of a Standard BS.
These items are referenced in the installation and operation steps
that follow. Note that SU radios may have an additional connector
present for Wi-Fi service, depending on order requirements. If
Wi-Fi is not provided on an SU, the GPS connector will also be
absent.
USB PORTS
(Mini-A, Type-A)
LED INDICATOR
PANEL
GPS ANTENNA
CONNECTION
Figure 1. Connectors and Indicators
(Standard BS shown; SU Similar)
1.2
Weatherproof Subscriber Unit
In addition to the Standard Subscriber Unit, a weatherproof Out-
door Unit (ODU) model is offered (see
designed for mounting on a tower, pole, or other elevated struc-
ture, and includes an integral panel antenna.
DC power is typically applied to the ODU through a Category 5
Ethernet cable (Cat. 5E, Cat. 6 also acceptable) which provides
Power-over-Ethernet (PoE) service. The cable can be up to 100
05-6301A01, Rev. 01
Invisible
place
holder
RS-232
SERIAL PORT
LAN PORTS
DC INPUT
(10–60 VDC, 4A MAX)
WiMAX RF
CHANNEL 2
WiMAX RF
CHANNEL 1
Figure
2). The ODU is
MDS Mercury Series Quick Start
MDS Mercury Series
meters in length (328 feet). For non-PoE models, a separate DC
power cable is required to supply 10-65 Vdc.
Figure 2. Mercury ODU Subscriber Unit
All operating parameters and commands for the ODU are identical
to those of the indoor SU. The only difference is in the physical
installation of the hardware on its support structure.
2.0
INSTALLATION—ALL UNITS
There are three main requirements for installing all units in the
transceiver system—adequate and stable primary power, a good
antenna system, and the correct interface between the transceiver
and the data device.
Figure 3
2.1

Installation Steps

Listed below are the basic steps for installation. It is highly recom-
mended that the BS be installed first so that you can quickly check
the operation of each associated SU as it is placed on the air.
RTU/PLC
Crossover Cable
to Radio
PC RUNNING
TERMINAL
PROGRAM
TO DC POWER SUPPLY
(Straight-Through
Cable to Radio)
Figure 3. Typical Mercury Installation (SU Shown; BS Similar)

Setup Guide

Invisible
place
holder
shows a typical Mercury installation.
Invisible
place
holder
ANTENNA SYSTEM
Subscriber: Panel Ant.
Base Unit: Sector Ant.
TO GPS ANTENNA
(Provides 3.3 Vdc output)
(10–60 Vdc)
1

Advertisement

loading

Summary of Contents for GE MDS Mercury Series

  • Page 1: Setup Guide

    DC power is typically applied to the ODU through a Category 5 Ethernet cable (Cat. 5E, Cat. 6 also acceptable) which provides Power-over-Ethernet (PoE) service. The cable can be up to 100 05-6301A01, Rev. 01 MDS Mercury Series Quick Start...