Summary of Contents for LG PQCPM11A0

  • Page 1 Web PDI Web based Power Distribution Indicator (PQCPM11A0) Installation/Owner's Manual Caution • Read this manual thoroughly before installing the product. • Only the certified professional should install this product. • Keep this manual for referring during the operation later.
  • Page 2: Table Of Contents

    Advanced Control Platform Contents 1. Web PDI Functions & Specification ....1-1 Functions of Web PDI .....................1-1 Denomination of Web PDI ....................1-3 Components of Web PDI ....................1-4 Hardware Specification of Web PDI ................1-5 2. Installing Web PDI ...........2-1 Wiring Digram........................2-2 Internal Wiring Digram....................2-3 Installing the Web PDI and Connecting the cable............2-4 •...
  • Page 3 3. Functions of ACCS ..........3-1 Monitoring the air conditioner status................3-1 Monitoring power consumption ...................3-2 Setting the system ......................3-6 4. Reference ............4-1 Troubleshooting......................4-1 Guide for Open source software ...................4-1 UTP cable connection chart...................4-2 Installation/Owner's Manual...
  • Page 4 Note for safety Note for safety In order to prevent the user's injury or the damage of the product, keep the followings to use the product. ■ The service center or the professional installation agency cettified by our company should perform the installation because the professional technique is required to install.
  • Page 5 • The non-professional may • The non-standard part cause accident, electric cause accident, electric may cause electric shock, shock, explosion or injury. shock, explosion or injury. explosion, injury or failure. LG-NET 1 LG-NET 2 LG-NET 3 LG-NET 4 Ext. Ethernet 1 MENU/ SELECT...
  • Page 6 Note for safety Do not install the product at the wet place. • It may cause to degrade the insulating ability and may cause fire. LG-NET 1 LG-NET 2 LG-NET 3 LG-NET 4 Ext. Ethernet 1 MENU/ Ethernet 2 SELECT...
  • Page 7 • It may cause fire or • It may cause accident or • Any shock to the product electric shock. failure. may cause failure. LG-NET 1 LG-NET 2 LG-NET 3 LG-NET 4 Ext. Ethernet 1 MENU/ SELECT...
  • Page 8: Web Pdi Functions & Specification

    • Indication of accumulated power for period by individual A/C • Accumulation of total power consumption • Web accessible GUI Note: This product (Web PDI, Model No. : PQCPM11A0) MUST BE INSTALLED with PDI (Model No. : PNU-D1S00, PQNUD1S00) Web PDI...
  • Page 9 Web PDI web server. Also, the demand control feature to control the demand power is controlled by directly connecting the Web PDI to the demand controller without installing a separate PC program. LG-NET 1 LG-NET 2 LG-NET 3 LG-NET 4 Ext.
  • Page 10: Denomination Of Web Pdi

    1. Web PDI Functions & Specification Denomination of Web PDI LG-NET 1 LG-NET 2 LG-NET 3 LG-NET 4 Ext. Ethernet 1 MENU/ SELECT Ethernet 2 Console Power Buttons and LCD Buttons and the LCD to display the network environment setting and other information...
  • Page 11: Components Of Web Pdi

    We are not responsible for any problem caused by using the adaptor other than the standardized one offered by us, so using any non-standard part should be prohibited. You can consult the LG System Air Conditioner Support Division about the applicable product.
  • Page 12: Hardware Specification Of Web Pdi

    1. Web PDI Functions & Specification Hardware Specification of Web PDI Item Description PXA255-400MHz Xscale 128MB (32x4) SDRAM • 512KB NOR Flash – Boot image • 128MB (64x2) NAND Flash – Program image, Database, others RS-232 Console For updating the program (for developing) •...
  • Page 13: Installing Web Pdi

    2. Installing Web PDI 2. Installing Web PDI This chapter describes how to install the Web PDI to use. Caution: Installing the Web PDI The Web PDI installation work needs the professional technique. Therefore, the installation described at this chapter should be performed by the certified installation professional.
  • Page 14: Wiring Digram

    2. Installing Web PDI Wiring Digram Address setup Start -> End LG-NET 1 (00) -> (03) LG-NET 2 Watt meter LG-NET 3 LG-NET 4 Ext. 3Ø 380VAC or Ethernet 1 MENU/ SELECT Ethernet 2 1Ø 220VAC Console Power Web PDI...
  • Page 15: Internal Wiring Digram

    2. Installing Web PDI Internal Wiring Digram PI-485 Multi V Indoor unit LG-NET 1 LG-NET 2 LG-NET 3 LG-NET 4 Ext. Ethernet 1 MENU/ SELECT Ethernet 2 Console Power Web PDI PI-485 communications A/B or 220~240VAC MultV/MultiV PLUS A/B 1P, 50/60Hz [ B->B / A->A ]...
  • Page 16: Installing The Web Pdi And Connecting The Cable

    2. Installing Web PDI Installing the Web PDI and Connecting the cable After setting the PDI, the Web PDI should be installed at the suitable place and the RS485 cable should be connected to communicate with the PDI. And, the Ethernet cable should be connected for connecting to the Internet.
  • Page 17: Connecting Rs485 Cable To Web Pdi

    The RS485 cable connecting to the PDI to the LG-NET port (RS485 port) of the Web PDI. Connect the connector connecting the RS485 cable to one of the ports LG-NET1~LG-NET4. The number of LG-NET ports is 1~4 and it is possible to connect to any of them to use.
  • Page 18: Connecting Ethernet Cable To Web Pdi

    Also, connect the cable by using the LAN tester to check whether the cable has any problem. For more information about the direct cable and the cross cable, see Chapter 4. UTP cable connection chart. A C T LG -N ET 1 L N K LG -N...
  • Page 19: Connecting Power Adaptor To Web Pdi

    After connecting the Ethernet cable, the power adaptor should be connected for supplying the power to the Web PDI. Connect the power adaptor supplied with the Web PDI product to the power adaptor connection port of the ACT as shown at the below figure. LG -N E T 1 LG -N E T 2...
  • Page 20: Configuring The Web Pdi Network

    Web PDI. The current Web PDI information and the menu are displayed at the LCD, and the menu can be changed and selected by pressing 'MENU/SELECT' button and Up/Down/Left/Right ( , buttons. LG-NET 1 LG-NET 2 LG-NET 3 LG-NET 4 Ext.
  • Page 21 2. Installing Web PDI Turning on the Web PDI Turn on the Web PDI to set the network environment of the Web PDI. C o n s o l e LG -N E T 1 LG -N E T 2 LG -N...
  • Page 22 2. Installing Web PDI Entering into the environment setup mode Press 'MENU/SELECT' button of the Web PDI to enter into the environment setup mode of the Web PDI. When the 'MENU/SELECT' button is pressed for the first time, the menu to set the IP address is displayed as shown below.
  • Page 23 2. Installing Web PDI How to set the network address The network address consists of four 3-digit numbers. In case of setting the network address, the name of the related address is displayed on the LCD of the Web PDI. Press Up/Down/Left/Right ( , ) button to set.
  • Page 24: Setting The Ip Address

    2. Installing Web PDI Setting the IP address In order for the user to use the functions of the Web PDI via the web, the unique IP address should be given to the Web PDI. Set the IP address as follows: Press the 'MENU/SELECT' button of the Web PDI.
  • Page 25: Setting The Gateway Address

    2. Installing Web PDI Setting the gateway address After setting the IP address, the gateway address should be set. Set the gateway address as follows: Press the 'MENU/SELECT' button of the Web PDI and then press Left/Right ( , ) button to display the following Gateway setup screen.
  • Page 26: Setting The Netmask Address

    2. Installing Web PDI Setting the netmask address After setting the gateway address, the netmask address should be set. Set the netmask address as follows: Press the 'MENU/SELECT' button of the Web PDI and then press Left/Right ( , ) button to display the following Netmask setup screen.
  • Page 27: Checking The Network Environment

    2. Installing Web PDI Checking the network environment When the IP address, the gateway address, and the netmask address are set, the essential network environment setup of the Web PDI is completed. So, make sure that all settings are successfully completed. Check the network environment setting as follows: Press the 'MENU/SELECT' button of the Web PDI and then press Left/Right ( , ) button to display the following Information screen.
  • Page 28: Configuring Indoor Units Information On Accs

    2. Installing Web PDI Configuring indoor units information on ACCS If previous installation step is done, next step should be configuration of indoor unit information. This step should be performed on ACCS program. The way of configuration is described as follows : Execute the Internet Explorer at the PC connected to tye Web PDI via the Internet or the internal network.
  • Page 29 2. Installing Web PDI When the IP address is correctly entered, the following LG ACCS Login screen is displayed. Enter the ID and the password and then click [Login] button. Set the ID to 'admin' and the password to 'digital21' for the first access to the Web PDI.
  • Page 30 2. Installing Web PDI When the login is successfully done, the initial screen of the LG ACCS is displayed as shown below. Click [Setting] button then, the system setup screen will be displayed. Click 2-24 Web PDI...
  • Page 31 2. Installing Web PDI Setting the air conditioner The following instructions shows how to configure indoor units. An example blue print is depicted in the below figure. Web PDI LG-NET 1 LG-NET 2 LG-NET 3 LG-NET 4 Ext. Ethernet 1...
  • Page 32 2. Installing Web PDI STEP 2. Click [Default] button then, outdoor unit information (group number) will be generated automatically. Click [Default] button to enter the default values STEP 3. Erase unnecessary units by click button. In this example we have 2 outdoor units. 2-26 Web PDI...
  • Page 33 2. Installing Web PDI STEP 4. Fill in the [Outdoor Unit Setting] window. For users°Ø information, refer to the table below. After that, Click OK. Item Description G/W No. Leave as it is with no setting. Outdoor unit No. (Group No.) Enter the number for identifying the outdoor unit (group).
  • Page 34 2. Installing Web PDI STEP 5. Click [Default] button then, outdoor unit information (group number) will be generated automatically. If users click the button [Default], above information will be generated automatically. STEP 6. Erase unnecessary units by click button. In this example we have 3 indoor units for each outdoor unit.
  • Page 35 2. Installing Web PDI STEP 7. Fill in the form. When you click the item to set, the related item changes to yellow, whose setting value can be modified. See the following table for the description on the item to set. Item Description Group name...
  • Page 36 2. Installing Web PDI Dip switch Description Physical address Enter the physical address of the indoor unit. The physical address consists of three numbers. The first number and the second number are the G/W number and the outdoor unit number respectively, which can be set within the information entered from the existing [G/W information] and [outdoor unit information].
  • Page 37: Functions Of Accs

    3. Functions of ACCS Monitoring power consumption To monitor the power consumption used by Groups or individual indoor unit, Click "Wattmeter" on the menu bar on top. Total/Group Consumption Total consumption shows the total amount of power consumed by the air conditioners connected with PDI.
  • Page 38 3. Functions of ACCS Displaying the wattage query period It displays the query period set by the user. Press the print button ( ) at the right side of the query period to print the displayed wattage by group with the Excel format. Group list It shows the list of groups configured at the system.
  • Page 39 3. Functions of ACCS Detailed history for each air conditioner Click button to display the detailed history of each air conditioner as follws: Besides the accumulated wattage of each air conditioiner, the daily wattage within the query period can be queried at the detailed history of each air conditioner.
  • Page 40 3. Functions of ACCS 'End' calendar The end date of the query period can be set at 'End' calendar. Apply & Cancel button When you click [Apply] button after setting the query period, the wattage within the set query period is displayed at 'Wattage' screen. When you click [Cancel] button, all settings up to now are cancelled and it returns to the previous screen.
  • Page 41: Setting The System

    3. Functions of ACCS Setting the system For the following cases, the air conditioner should be registered at or deleted from the system by the LG ACCS. • Installing the Web PDI for the first time • Adding a new air conditioner.
  • Page 42 3. Functions of ACCS Group input window A new group is added or the information of the existing group can be changed or deleted at the Group input window. Also, the group information and the indoor unit information can be conveniently entered by using the default input button.
  • Page 43 3. Functions of ACCS Air conditioner information input window and Temporary saving window You can add, modify or delete the indoor unit or the ventilator. Air conditioner information input You can set a new indoor unit or ventilator information at this window. First, in order to add a new indoor unit or ventilator, click the related input column.
  • Page 44 3. Functions of ACCS The information to set at the air conditioner is as follows: Item Description Type of indoor unit or ventilator. The indoor unit types to set are as follows: Type • UAC: Unified air conditioner This item is not set for the ventilator. Enter the physical address of the indoor unito or the ventilator.
  • Page 45 3. Functions of ACCS Temporary saving window It is convenient to use this window to move the indoor unit or the ventilator to the other group or to change the order. After specifying the air conditioner or the ventilator, press button to move it to the temporary saving window.
  • Page 46 3. Functions of ACCS Caution: Deleting the outdoor unit When the outdoor unit information is deleted, the information of the indoor unit connected the related outdoor unit is also deleted. Item Description G/W Number Leave as it is with not modified. Outdoor unit number Enter the outdoor unit number.
  • Page 47 The administrator information can be entered at 'System setup' menu. The administrator information is the right to log in to the LG ACCS. When you click [Administrator information] at the right side of the screen, the IP/PW input window is displayed.
  • Page 48 3. Functions of ACCS Save and Reset button Save and Reset button are located at the bottom of the Setting Window. Reset button is used to reload the previously saved information. Save button is used to save the information currently showed on the screen. Reset button Click [Reset] button to reload the already saved information.
  • Page 49 3. Functions of ACCS Save button Click [Save] button to change the information. When you click [Save] button, the window for confirming to execute the command is displayed. Click [OK] button to confirm the command. Click [Cancel] button to cancel the command and return to the previous state.
  • Page 50: Reference

    4. Reference 4. Reference Troubleshooting If users have any unexpected problem, please Visit our web site http://www.lgservice.com Guide for Open source software The following GPL/LGPL execution files and libraries used at this product conform to the GPL/LGPL license contract. GPL execution file Linux kernel 2.4 fdisk Irzsz...
  • Page 51: Utp Cable Connection Chart

    4. Reference UTP cable connection chart UTP cable The Unshielded Twisted Pair (UTP) cable is a sort of the signal line connecting the LAN environment. Two copper lines insulated for reducing the electromagnetic induction Twisted between two lines are twisted to form the copper line twisted pair.
  • Page 52 P/No.: MFL37115843 Printed in Korea After reading this manual, keep it in a place easily accessible to the user for future reference.

Table of Contents