hit counter script
Siemens SIMATIC IPC427E Operating Instructions Manual

Siemens SIMATIC IPC427E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC427E:
Table of Contents

Advertisement

SIMATIC
Industrial PC
SIMATIC IPC427E
Operating Instructions
09/2017
A5E37454814-AB
___________________
Preface
___________________
Overview
___________________
Safety Instructions
___________________
Installing and connecting the
device
___________________
Commissioning the device
___________________
Extended device functions
___________________
Expanding and assigning
parameters to the device
___________________
Device maintenance and
repair
___________________
Technical specifications
___________________
Technical support
___________________
Markings and symbols
___________________
List of abbreviations
1
2
3
4
5
6
7
8
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC427E

  • Page 1 ___________________ Preface ___________________ Overview ___________________ SIMATIC Safety Instructions ___________________ Installing and connecting the device Industrial PC SIMATIC IPC427E ___________________ Commissioning the device ___________________ Extended device functions Operating Instructions ___________________ Expanding and assigning parameters to the device ___________________ Device maintenance and...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    "Technical specifications (Page 105)". Position in the information landscape The IPC documentation comprises: ● SIMATIC IPC427E Quick Install Guide with product information about the device, for example important notes ● SIMATIC IPC427E Operating Instructions The documentation is supplied with the IPC in multiple languages in electronic form as a PDF file on the USB stick supplied in the documentation package.
  • Page 4 Preface Conventions The terms "PC" and "device" are sometimes used to refer to the SIMATIC IPC427E in this documentation. The term "Windows Embedded Standard" is used throughout to refer to "Windows Embedded Standard 7". "Windows 7" is used as an abbreviation for "Windows 7 Ultimate".
  • Page 5: Table Of Contents

    3.3.5 Connecting the terminal ......................40 3.3.6 Connecting the power supply ....................41 3.3.7 Connecting the device to networks ..................42 3.3.8 Installing the strain relief ......................43 3.3.9 Securing the lines ........................44 SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 6 7.4.1 Reinstalling the operating system ..................81 7.4.1.1 General installation procedure ....................81 7.4.1.2 Restoring the factory state ..................... 83 7.4.1.3 Windows 7 / Windows 10 ....................... 84 7.4.1.4 Windows Embedded Standard ....................87 SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 7 Watchdog trigger register (read only, address 066h) ............122 8.6.4.4 Output register user LED L1/L2/L3 (read/write, address 404Eh) ......... 122 8.6.4.5 Battery status register (read-only, address 404Dh) .............. 123 8.6.4.6 NVRAM address register ...................... 123 SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 8 Markings and symbols ......................... 143 Overview ..........................143 Safety ........................... 143 Operator controls ......................... 143 Certificates, approvals and markings ................... 144 Interfaces ..........................145 List of abbreviations ..........................147 Glossary .............................. 153 Index ..............................161 SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 9: Overview

    Overview Product description The SIMATIC IPC427E provides high-level industrial functionality. ● Compact design ● Maintenance-free operation ● High degree of ruggedness SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 10: Applications

    2 x DisplayPort, maximum resolution 4096 x 2304 pixels • Graphics memory is claimed in main memory (dynamic UMA) • Power supply 24 V DC (-20%/+20%) max. 4 A Conditions of use Operation without fan SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 11 4 LEDs for displaying system statuses; 3 of these can be freely pro- grammed by the user Transient voltage interruption Up to 15 ms buffer time at full load Buffer memory 512 KB optional Integrated Trusted Platform Module, optional, according to TPM 2.0 standard SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 12 1.1 Product description Software Operating systems Available None • Windows Embedded Standard 7, SP1 • Windows 7 Ultimate, SP1 • Windows 10 IoT Enterprise LTSB 2016, 64-bit • Project-specific LINUX • • VxWorks • SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 13: Design Of The Device

    2 x DisplayPort DisplayPort connection for digital monitor ⑦ 3 × Ethernet / 2 x Ethernet RJ45 interface (10/100/1000 Mbps); 2 x RJ45 (optional) ⑧ COM1 Serial interface (optional) ⑨ COM2 Serial interface (optional) SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 14: Status Displays

    Output register user LED L1/L2/L3 (read/write, address 404Eh) (Page 122). Example programs for controlling the LEDs on Windows operating systems are available on the Customer Support page of Siemens Industry Automation and Drive Technologies. (http://www.siemens.com/automation/service&support) SIMATIC IPC427E...
  • Page 15: Accessories

    Overview 1.3 Accessories Accessories Siemens offers accessories not included in the scope of delivery for the device. For more information on available accessories, refer to the Internet at: Industry Mall (https://mall.industry.siemens.com) Expansion components and accessories (http://www.automation.siemens.com/mcms/pc- based-automation/en/industrial-pc/expansion_components_accessories) SIMATIC IPC CFast cards ●...
  • Page 16 Overview 1.3 Accessories SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 17: Safety Instructions

    The installation of expansions can damage the device, machine or plant. Device and system expansions may violate safety rules and regulations regarding radio interference suppression. If you install or exchange system expansions and damage your device, the warranty becomes void. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 18 • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and protect from direct sunlight, moisture and condensation. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 19 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 20 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats.
  • Page 21: Notes On Usage

    • Observe the permitted mounting positions of the device. • Do not obstruct the venting slots of the device. • Always use suitable cleaning agents. Read the information about Chemical resistance of the HMI devices and industrial PCs (http://support.automation.siemens.com/WW/view/en/39718396) on the Internet. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 22 Use in an industrial environment without additional protective measures The device has been designed for use in a normal industrial environment in accordance with IEC 60721-3-3 (pollutant class 3C2 for chemical influences, 3S2 for dust without sand). SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 23: Installing And Connecting The Device

    • Keep the original packaging. • Pack the device in the original packaging for transportation and storage. 5. Check the contents of the packaging and any accessories you may have ordered for completeness and damage. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 24 7. Please keep the enclosed documentation in a safe place. It belongs to the device. You need the documentation when you commission the device for the first time. 8. Write down the identification data of the device. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 25: Identification Data Of The Device

    Side surface of Only devices with preinstalled the device Windows operating systems Certificate of Authenticity (COA) have COA labels Ethernet address 1 BIOS setup, "Ad- vanced" menu Ethernet address 2 Ethernet address 3 (optional) Rating plate SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 26 You usually do not need this product key for commissioning because a valid product key has already been integrated into the pre-installed operating system. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 27: Permitted Mounting Positions

    DIN-EN 60950-1, sections 4.6 and 4.7.3. Horizontal mounting is the preferred position. The horizontal mounting options are as follows: Installation on a DIN rail The interfaces are at the bottom. Wall mounting The interfaces are at the bottom. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 28 The interfaces are the left. at the front. The power supply con- nection is at the top. Observe the permitted temperature range for operation in the respective mounting position as defined in "Technical specifications (Page 105)". SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 29: Installing The Device

    The device may not be securely fitted if you use anchors and screws other than those specified below for mounting. The device can fall and may be damaged. Use only the anchors and screws specified in the following table. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 30 8 mm, 40 mm deep Dowel, ∅ 8 mm, 40 mm length • Screw, ∅ 5 mm, 40 mm length • Plasterboard, 14 mm Toggle bolt, ∅ 4 mm, 50 mm length min. 13 mm thickness SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 31: Installation On A Din Rail

    The fasteners and screws required are supplied with the device for the selected mounting option (as specified in order number). Requirement ● 1 DIN rail clip ● 4 screws ● 1 T20 screwdriver Procedure 1. Fasten the DIN rail clip with four screws. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 32: Mounting On Din Rails

    Removal 1. Push down the device until it is released by the rail clips. 2. Swing the device out of the standard profile rail. 3. Lift the device up and off. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 33: Wall Mounting

    The fasteners and screws required are supplied with the device for the selected mounting option (as specified in order number). Requirement ● 2 mounting brackets ● 6 screws ● 1 T20 screwdriver Procedure 1. Secure each mounting bracket with 3 screws. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 34: Upright Mounting

    The fasteners and screws required are supplied with the device for the selected mounting option (as specified in order number). Requirement ● 2 mounting brackets ● 6 screws ● 1 T20 screwdriver Procedure 1. Secure each mounting bracket with three screws. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 35: Connecting The Device

    • Only connect I/O devices which are approved for industrial applications in accordance with EN 61000-6-2 and IEC 61000-6-2. • I/O devices that are not hotplug-capable may only be connected after the device has been disconnected from the power supply. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 36 Regenerative feedback of voltage to ground by a connected or installed component can damage the device. Connected or built-in I/Os, for example, a USB drive, are not permitted to supply any voltage to the device. Regenerative feedback is generally not permitted. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 37: Connecting The Protective Conductor

    1. Crimp the cable lug onto the protective conductor. 2. Screw the cable lug onto the protective conductor connection as shown. 3. Wire the protective conductor to the protective conductor connection of the control cabi- net in which the device is installed. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 38: Connecting Peripheral Equipment

    • The computer in question must be turned off. • During the measurement, all cables from the plant to the computer should be connected. • All other components in the plant must be active. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 39: Connecting Expansion Cards

    3. Attach the cover at the points shown and close it. Make sure that the latching hooks snap into place so that the cover is secured. See also Dimension drawing - device with expansion cards (Page 104) SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 40: Connecting The Terminal

    Make sure that the cores are connected to the correct terminals. Observe the labeling for the contacts on the front cover of the device. 1. Connect the lines as shown. Make sure the connection terminal is in the correct position as shown. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 41: Connecting The Power Supply

    The corresponding 24 V DC power supply is off. ● 1 0.5 × 3 Philips screwdriver Procedure 1. Insert the terminal at the marked position. 2. Secure the terminal using the inte- grated screws. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 42: Connecting The Device To Networks

    Note To use the Windows reboot with the SIMATIC CPU1507S (F) Software Controller on the SIMATIC IPC427E, assign the Ethernet interfaces X2 or X3 to the PC station in STEP 7. Industrial Ethernet You can establish a network between the device and other PCs via Industrial Ethernet. The on-board LAN interfaces are (Twisted-Pair) TP interfaces that support data transmission rates of 10/100/1000 Mbps.
  • Page 43: Installing The Strain Relief

    1. Removed the indicated countersunk screws and fasten the strain relief at the indicated points. Use the oval head screws included with the strain relief. Removal Follow the steps for installation in reverse order. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 44: Securing The Lines

    Cable tie width 3 mm max. ● 1 cutting tool Procedure 1. Pass the cable tie around the strain relief bar and secure the cables as shown. 2. Cut off the protruding ends of the cable ties. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 45: Commissioning The Device

    Configuring memory cards in the device Memory cards used in a device need to be configured on that device. Memory cards configured on other devices will not boot as the drive parameters will be different. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 46 ● The protective conductor is connected. ● The connection cables are plugged in correctly. ● The following hardware is available for initial commissioning: – One USB keyboard – One USB mouse – A monitor/display SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 47: Initial Commissioning

    6. If the device is connected with a SIMATIC Industrial Flat Panel, the setup of the SIMATIC IPC Panel Drivers and Tools software is started automatically after operating system installation (see next section). The installation of the operating system is complete. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 48: Windows Action Center

    ● Configuration via the IPC Configuration Center of: – Brightness – Screen saver – Tools – Touch settings – Ethernet Monitor settings All other functions are described in the IPC Panel Driver and Tools operating manual. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 49: Extended Device Functions

    The SIMATIC IPC DiagMonitor software can be ordered as an accessory (not included in the scope of delivery). The CD contains both the monitoring software and the software for the stations to be monitored. The interface specifications and a library for creating your own applications are also provided. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 50: Temperature Monitoring/Display

    The temperature error is saved until the temperatures have fallen below the thresholds and it is reset by one of the following measures: ● Acknowledgment of the error message by the user with DiagBase or DiagMonitor software ● Restart of the device SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 51: Watchdog (Wd)

    Windows and damage to the installation. Watchdog monitoring times The monitoring time can be configured with the DiagBase or DiagMonitor software. Note When you change the monitoring time, the change becomes effective immediately. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 52: Battery Monitoring

    Proceed as follows to prevent this situation: • Make changes to storage media only when UWF is disabled. See also SIMATIC IPC Windows 10 User Manual (https://support.industry.siemens.com/cs/ww/de/view/109749498/en?dl=en) SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 53: Enhanced Write Filter (Ewf)

    Note Windows Embedded Standard The Enhanced Write Filter is deactivated in the Windows Embedded Standard default state. • Back up your data after installation of the operating system and programs. • Activate the EWF. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 54 ● "Start > All Programs >Siemens Automation > SIMATIC > EWF Manager > EWF Manager" Configure the SIMATIC IPC EWF Manager as follows: ● "Start > All Programs > Siemens Automation > SIMATIC > EWF Manager > EWF Settings" ● Click the "SIMATIC IPC EWF Manager" icon in the system tray.
  • Page 55 "Start > Control Panel > Date and Time", remove the check mark from the "Automatically adjust clock for daylight saving changes" check box. 2. Save the change you have made with and then reboot the system. ewfmgr c: commit SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 56: File Based Write Filter (Fbwf)

    This may damage the machine or plant. Make sure that you only activate one write filter for each partition. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 57 • fbwfmgr /removeexclusion Remove file • C: \Test.txt fbwfmgr /removeexclusion C: \Test Remove folder • folder fbwfmgr /? Call up the help function Detailed instructions on FBWF are available on the Internet (http://msdn.microsoft.com/en- us/library/aa940926(WinEmbedded.5).aspx). SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 58: Buffer Memory Nvram

    An ISO file contains a memory image of the content of a CD or DVD structured in the ISO 9660 format. ● Remote reboot: An AMT PC can be booted from a bootable ISO file made available by another PC. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 59 SIMATIC IPC Remote Manager The "SIMATIC IPC Remote Manager" software is available for utilization of the AMT functions with SIMATIC IPCs. The software can be ordered from the Siemens online ordering system. For detailed information about "SIMATIC IPC Remote Manager", refer to the corresponding product documentation: SIMATIC IPC Remote Manager (http://support.automation.siemens.com/WW/view/en/48707158)
  • Page 60: Trusted Platform Modul (Tpm)

    The warranty does not cover a reset of the hardware in the event of a loss of a password. Please store the password carefully and make sure it is protected against unauthorized access. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 61: Expanding And Assigning Parameters To The Device

    You therefore need to take precautionary measures before you open the device. Please refer to the ESD Directives on handling electrostatic-sensitive components in ESD guideline (Page 98). Requirement ● The device is disconnected from the power supply. ● 1 T10 screwdriver SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 62 5. Remove the backup battery from its guide in the front panel. Observe the information in section "Installing and removing the backup battery (Page 76)". 6. Put down the front panel. Closing the device Proceed in reverse order. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 63: Opening The Device Containing Expansion Cards

    Procedure Opening the device 1. Remove the marked screws. 2. Lift off the front panel in the direction of the arrow 3. Put down the front panel. Closing the device Proceed in reverse order. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 64: Replacing Memory Modules

    The motherboard is equipped with one slot for an SO-DIMM DDR4 memory module. You can use it to expand the memory capacity of the device to a maximum of 16 GB. Note Use only the memory modules recommended by Siemens AG. Requirement ● The device is disconnected from the power supply.
  • Page 65 BIOS Setup menu under "Total Memory". After insertion and removal Close the device. The new memory capacity will be automatically detected and displayed in the BIOS setup when the device is switched on. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 66: Installing And Removing Cfast Cards

    Use the slot described here only for a CFast card; otherwise, the device will be damaged. Requirement ● The device is switched off. ● SIMATIC IPC CFast card that is approved for industrial applications. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 67 Push CFast card into the slot until it snaps into place. 3. Close and lock the cover. Removal Remove the CFast card from the memory slot by pushing it in until it is ejected by about 5 Proceed in reverse order. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 68: Installing And Removing Pcie Cards

    The temperature in the PCIe slot of the IPC is around 15 K higher than the ambient temperature. This means the maximum permissible ambient temperature may be lower than for the IPC427E alone. Figure 6-1 Device version with one PCIe slot SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 69 You can also use a slot plate with connector perforations. ● 1 T10 screwdriver Procedure Installation Note Observe the guidelines for handling electrostatic-sensitive components in section "ESD guideline (Page 98)". SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 70 Removal Proceed in reverse order. Configuring BIOS setup You may need to make settings in the BIOS Setup. For detailed information about installation, please refer to the documentation provided with the specific expansion card. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 71: Assigning Cpu Power Consumption Parameters

    Same as standard, but additionally optimized for deterministic operation with optimized constant CPU frequency. Temperature Setting for lowest power consumption. optimized The CPU clock is limited at a higher load. The maximum power consumption of the CPU is 12 W. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 72 Expanding and assigning parameters to the device 6.4 Assigning CPU power consumption parameters SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 73: Device Maintenance And Repair

    Unauthorized opening and improper repairs on the device may result in substantial damage to equipment or endanger the user. If you install or replace a system expansion and damage your device, the warranty will become void. The device may only be repaired by qualified personnel. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 74 Do not recharge, open, or short lithium batteries. Do not reverse lithium battery polarity or heat the batteries to over 100°C. Keep lithium batteries out of direct sunlight and protect them from moisture and condensation. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 75 UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". We are not liable for functional limitations caused by the use of third-party devices or components. See also Spare parts and repairs (http://support.automation.siemens.com/WW/view/en/16611927) SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 76: Installing And Removing Hardware

    Dispose of used batteries in accordance with local regulations. Requirement ● The device is disconnected from the power supply. ● No peripherals such as a mouse, keyboard or monitor are connected. ● 1 T10 screwdriver SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 77 2. Carefully remove the connector. 3. Remove the battery holder from the en- closure guide. 4. Remove the battery from the battery holder. Procedure - Installation Install the device by following the same steps in the reverse order. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 78: Changing Storage Media

    1. Remove the wall mounting bracket or the vertical mounting bracket, if any, and then the indicated screws. Push the cover in the direction indicated and lift it off. 2. Remove the marked screws. These screws secure the HDD/SSD. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 79 2. Insert the new HDD/SSD into the enclo- sure. Take care that the nameplate is on top. Slide the HDD/SSD into the enclosure until you can see the mounting holes. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 80 Device maintenance and repair 7.3 Installing and removing hardware 3. Turn in the marked screws. 4. Insert the cover into the enclosure. Turn in the marked screws. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 81: Installing The Software

    The supplied USB contains the installation program with tools for configuring the drives and installing the operating system with the supported languages. The basic language of the installed operating system is English. To add other languages, install these languages from the supplied USB stick ("Language packs" directory). SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 82 The supplied USB stick contains the documentation, hardware drivers and updates. In Windows, these contents are available via a menu. Restore function If you have ordered IPC427E with operating system, the supplied USB stick contains the Restore function. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 83: Restoring The Factory State

    4. To boot from the USB stick, select the Boot Manager. 5. Select the USB stick in the Boot Manager and confirm the entry. 6. Select the Restore function and confirm the entry. 7. Follow the on-screen instructions. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 84: Windows 7 / Windows 10

    The BIOS selection menu is displayed when initialization is completed. 4. To boot from the USB stick, select the Boot Manager. 5. Select the USB stick in the Boot Manager and confirm the entry. 6. Select the Recovery function and confirm the entry. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 85 For this purpose, you can either select one of the preinstalled languages or install a new language package. The following command sequences are described in English. Depending on the default setting, they can be displayed in another language. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 86 3. Click the "Install/uninstall languages" button and make the required changes. The following languages can be installed at a later time: Language Windows 7 / 10 German English French Italian Spanish Chinese (Hong Kong) Chinese (simplified) Chinese (Taiwan) Japanese Russian SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 87: Windows Embedded Standard

    Note the license terms of Windows Embedded Standard 7 Note the license terms for Windows Embedded Standard 7 and especially the extended software terms of the Siemens AG. You can find the license terms in the delivered document "MICROSOFT SOFTWARE LICENSE TERMS for Windows Embedded Standard 7"...
  • Page 88 8. After selecting the menu dialog language, select the menu entry "Manage language packages". Depending on the current language setup, you have the following options in the "Manage language packages" menu: – Display language settings – Install language – Change language – Uninstall installed language SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 89: Partitioning The Data Storage Medium

    Second Data Remainder Remainder NTFS not compressed To restore the partitions to their original delivery state, we recommend the software SIMATIC IPC Image & Partition Creator. Additional information is available in the accompanying documentation. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 90: Setting Up The Partitions Under Windows 7 Ultimate And Windows 10

    SSD/HDD: > 100 GB First Boot 260 MB FAT32 Second 128 MB None Third System 60 GB 100 GB NTFS, not compressed Fourth WinRE 500 MB NTFS, not compressed Fifth Data Remainder NTFS, not compressed SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 91: Adapting The Partitions Under Windows 7 Ultimate And Windows 10

    1. Click in the partition manager with the right mouse button on the partition to be increased and click on "Increase size". 2. Follow the instructions on the screen. Additional information is available in the "Help" menu under "Help topics" and "Search". SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 92: Installing Drivers And Software

    6. Open the folder with the driver data by clicking on the link next to "Driver path". 7. Start the setup program in this folder. Note For a new installation of Windows operating systems, the chipset driver must be installed before all other drivers, if required. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 93: Update Installation

    (images). The SIMATIC IPC Image & Partition Creator can be ordered using the Siemens online ordering system (https://mall.industry.siemens.com). For more information about SIMATIC IPC Image & Partition Creator, refer to its product documentation.
  • Page 94 Device maintenance and repair 7.5 Recycling and disposal SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 95: Technical Specifications

    Certificates and approvals ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001:2008. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 96 This product meets the requirements of Korean certification. This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 97: Declaration Of Conformity

    RoHs directive This product meets the requirements stated in the RoHS directive (Restriction of Hazardous Materials): 2011/65/EU Compliance with the directive has been reviewed according to the following standard: EN 50581 SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 98: Directives And Declarations

    The consequences are incalculable and range from unforeseeable malfunctions to a total failure of the machine or system. Avoid touching components directly. Make sure that persons, the workstation and the packaging are properly grounded. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 99 There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 100 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 101: Dimension Drawings

    Technical specifications 8.4 Dimension drawings Dimension drawings 8.4.1 Dimension drawing - mounting on a DIN rail SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 102: Dimension Drawing - Wall-Mounting

    Technical specifications 8.4 Dimension drawings 8.4.2 Dimension drawing - wall-mounting SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 103: Dimension Drawing - Vertical Mounting

    Technical specifications 8.4 Dimension drawings 8.4.3 Dimension drawing - vertical mounting SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 104: Dimension Drawing - Device With Expansion Cards

    Technical specifications 8.4 Dimension drawings 8.4.4 Dimension drawing - device with expansion cards Device with one expansion card Device with two expansion cards SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 105: Technical Specifications

    (SELV) according to IEC/EN/DIN EN/UL 60950-1. The power supply must meet the requirement NEC Class 2 or LPS according to the IEC/EN/DINEN/UL 60950-1 (see section "Connecting the power supply (Page 41)"). SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 106 Expansion card slots up to 2 x PCIe cards can be used Max. length of PCIe cards: 175 mm max. permitted power losses: 8 W per PCIe card, 12 W in total For devices with retentivity SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 107 (Intel 1x I219LM, 2 x I210) 10/100/1000 Mbps, electrically isolated, teaming-capable For unique labeling, the Ethernet interfaces are numbered on the enclosure. The numbering by the operating system can differ. No teaming with AMT. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 108: Ambient Conditions

    - During operation 1080 up to 689 hPa, (corresponds to an elevation of -1000 to 3000 m) - During storage/shipping 1080 to 660 hPa (corresponds to an altitude of -1000 m to 3500 m) SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 109 Tested to DIN IEC 60068-2-27 - During operation without hard disk drive: 150 m/s , 11 ms; with hard disk drive: 50 m/s , 30 ms - During storage/shipping 250 m/s , 6 ms SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 110: Power Demand Of The Components

    The peak value of the starting current depends on the input voltage and the impedance of the 24 V DC power supply. Peak currents greater than 6.5 A are possible. This will not have a negative impact on device functionality. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 111: Typical Power Consumption

    SSD - additionally USB expansion - additionally Max. 500 mA Max. 12 W PCIe expansion - additionally Max. 500 mA Max. 12 W The total power for PCIe and USB expansions may not exceed 15 W SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 112: Hardware Descriptions

    Pin assignment RS422 Short description Meaning Transmit data - (O) for full-duplex mode Transmit data + (O) for full-duplex mode Receive data + (I) for full-duplex mode Receive data - (I) for full-duplex mode Signal ground SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 113: Cfast

    LED Output (not connected) PC10 Reserved Input/Output (not connected) PC11 Reserved Input/Output (not connected) PC12 Reserved Input/Output (not connected) PC13 Device Power (3.3V) PC14 Device Power (3.3V) PC15 Device GND PC16 Device GND PC17 Card Detect Out SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 114: Displayport

    Output Ground ML_Lane3- DP data 3- Output CONFIG1 CAD Cable Adapter Detect Input CONFIG2 Ground (PullDown) AUX_CH+ Auxiliary channel+ Bidirectional Ground AUX_CH- Auxiliary channel- Bidirectional Hot Plug Detect Input Ground DP_PWR +3.3V (fused) Output SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 115: Ethernet

    + 5 V (fused) Output Data channel USB2 Input / output Data channel USB2 Input / output Ground – Data channel USB3 Input Data channel USB3 Input Ground – Data channel USB3 Output Data channel USB3 Output SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 116: Internal Ports

    Receiver differential pair, Lane 0 PRSNT2# Hot-plug presence detect PERn0 Receiver differential pair, Lane 0 (not connected) Ground Ground PETp1 Transmitter differential pair, RSVD Reserved Lane 1 PETn1 Transmitter differential pair, Ground Lane 1 SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 117 Lane2 PETp3 Transmitter differential pair, Ground Lane3 PETn3 Transmitter differential pair, Ground Lane3 Ground PERp3 Receiver differential pair, Lane3 RSVD Reserved PERn3 Receiver differential pair, Lane3 PRSNT2# Hot-plug presence detect Ground Ground RSVD Reserved SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 118: System Resources

    Free IRQ6 Free IRQ7 Free IRQ8 System CMOS / real-time clock ISA exclusive IRQ9 ACPI-SCI (system control interrupt) IRQ10 Free IRQ11 SMBUS PCI shared NVRAM (optional) IRQ12 Free IRQ13 Numeric data processor ISA exclusive SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 119 Graphics Management Engine Interface USB XHCI Controller IRQ17 PCIe-x4 slot on Riser PCI exclusive IRQ18 PCIe-x1 slot on Riser PCI shared LAN2 (I210) IRQ19 LAN3 (I210) (optional) PCI exclusive IRQ20 Free IRQ21 Free IRQ22 Free IRQ23 Free SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 120: I/O Address Areas

    210 ms / 4 s 340 ms / 6 s 460 ms / 8 s 590 ms / 16 s 710 ms / 32 s 840 ms / 48 s 960 ms / 64 s SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 121 Watchdog enable register / 066h select register (r/w address 062h) Trigger red Watchdog LED Red LED (WD) off Red LED (WD) on Watchdog error / Display and reset WD inactive WD triggered Reset LED after watchdog alarm (Bit 7 = write 1) SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 122: Watchdog Trigger Register (Read Only, Address 066H)

    LED L2 / SF lit red LED L2 / SF lit yellow LED L3 / Maint dark (default) LED L3 / Maint lit red LED L3 / Maint lit yellow xxxx xxxx Reserved (read/write) SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 123: Battery Status Register (Read-Only, Address 404Dh)

    NVRAM address register PCI register address: PCI register content: Length of the memory area NVRAM base address regis- NVRAM memory address (default) E300 0000 Address is assigned dynamically 80000 h (depending on device configura- tion) SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 124: Bios Description

    Setup parameters may not be included, depending on your order. The interface of your BIOS Setup can deviate from the figures in this document. You can find a detailed description of the BIOS on the Support website under Entry ID 92189178 (http://support.automation.siemens.com/WW/view/en/92189178). SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 125: Opening The Bios Selection Menu

    BIOS Update Update BIOS from USB memory stick MEBx Start Intel Management Engine BIOS Extension from Active Manage- ment Technology Support (AMT) Supported by Windows 8 and higher See also General installation procedure (Page 81) SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 126: Structure Of The Bios Setup Menu

    Determine boot options, e.g., boot order Exit Save and exit (see Exit menu) The menus always have the same structure. The figure below shows an example for the "Main" menu. Device-specific information is shown blurred. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 127 Short help texts on the currently selected setup parame- ters are displayed in the center right-hand area. ⑤ Key assignment The key assignment for navigation in the BIOS Setup is found in the footer. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 128: Exit Menu

    Save the BIOS Setup settings as user-specific profile. • Save Custom Defaults The currently configured Setup parameters are saved as a custom profile (see also "Load Custom Defaults"). Discard Changes All changes are discarded. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 129: Bios Update

    BIOS update Check regularly if updates are available for download to your device. Additional information can be found on the Internet at the following address: After Sales Information System (http://www.siemens.com/asis). Noting down and restoring BIOS Setup settings NOTICE Irretrievable loss of data All BIOS Setup settings are deleted after the BIOS update.
  • Page 130 There may be several reboots after a BIOS update. These reboots are initiated by the Management Engine (ME). The reboots are required by the ME to adapt itself to the changes of the BIOS update. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 131: Alarm, Error And System Messages

    The CMOS clock was operated without battery or with a battery that was too weak, during bat- tery change, for example. Check the CMOS clock. Keyboard controller error Keyboard defective or not connected no keyboard present SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 132: Active Management Technology (Amt)

    SIMATIC IPC with Intel® AMT from it. The following figure shows remote maintenance of SIMATIC IPCs with Intel® AMT, e.g. for troubleshooting a corrupt operating system or incorrect BIOS settings: SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 133: Overview Of Amt

    5. Activate the options "Intel AMT Configuration Screens". 6. For IPC547D and PC547E devices only: Select the "Normal" setting for "MEBx Mode". 7. Exit the BIOS Setup with the <ESC> key. 8. Start the MEBx Setup via "MEBx". SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 134 5. Switch to the "Intel(R) ME General Settings" submenu and enable access via the network with "Activate Network Access". 6. Confirm the dialogs that appear with "Y". Drivers are automatically installed once as required in the subsequent restart. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 135: Resetting The Intel® Amt To The Default Settings And Disabling Amt

    Management Engine (ME). The following message appears: "Unconfiguration in process...". The device is automatically restarted. 9. For IPC627C/827C/677C/647C/847C/427D/427E/477D/477E/Field PG M4, you now need to set the "Un-Configure ME" menu item in the BIOS back to Disabled. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 136: Determining The Network Address

    2. Select the value "KVM" for "User Consent". To allow a user with administrator privileges to avoid this code query, follow these steps: 1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx. 2. Enable "Opt-in configurable from remote IT". SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 137: Functional Scope In Windows

    Printing Utilities and Management Available Available Registry Filter Available Available Remote Assistance Available Available Remote Client Available Available Remote Desktop Available Available SIMATIC IPC DiagBase Available Available Speech Available Not available System Management Administrative Tools Available Available SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 138 Note the licensing agreements for Windows Embedded Standard 7. Additional information on language selection is available in the section "Setting up the language selection by means of the Multilanguage User Interface (MUI) (Page 85)". SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 139: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa- db/en/Pages/default.aspx)
  • Page 140: Troubleshooting

    Install a suitable driver; the correct driver can often be downloaded does not have a suitable from the homepage of the device's manufacturer. driver for the USB device. The EWF for Windows Embedded Standard must first be disabled. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 141: Notes On The Use Of Third-Party Modules

    PC. If the error no longer occurs, the third- Signal frequencies or signal • party expansion card was the cause of the fault. Replace levels are not adhered to this expansion card with a Siemens card or contact the card Different connector pin as- • supplier. signments If the PC still crashes, contact your technical support team.
  • Page 142 Technical support A.3 Notes on the use of third-party modules SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 143: Markings And Symbols

    Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 144: Certificates, Approvals And Markings

    CE markings for European countries Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters La- Disposal information, observe the boratories local regulations. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 145: Interfaces

    DVI-D interface Line In LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 146 Markings and symbols B.5 Interfaces SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 147: List Of Abbreviations

    Complementary Metal Oxide Semiconductors Complementary metal oxide semiconductors Certificate of authentication Microsoft Windows Product Key Certificate of License License authorization Communications Port Term for the serial interface Communication Processor Communication computer Central Processing Unit Cathode Ray Tube SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 148 Frequently Asked Questions FAQs FAT 32 File Allocation Table 32-bit 32-bit file allocation table FBWF File Based Write Filter Floppy disk Disk drive, 3.5" Front Side Bus Ground Chassis ground Hard disk Hard disk SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 149 Multipoint-capable interface for programming devices MS-DOS Microsoft Disc Operating System MTBF Mean Time Between Failures Multilanguage User Interface Multilanguage operating system with Windows with language toggling; 5 languages: German, English, French, Spanish and Italian Not Applicable SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 150 Bi-directional bus system designed for up to 32 nodes Real Time Clock Real-time clock Reliable Transfer Service Request to send Receive Data Data transfer signal SATA Serial Advanced Technology Attachment SCSI Small Computer System Interface SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 151 Virtualization Technology Intel technology with which a virtually closed environment can be made available. VT-D Virtualization Technology for Directed I/O Enables the direct assignment of a device (e.g. network adapter) to a virtual device. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 152 Program monitoring with error detection and alarming. WLAN Wireless LAN Wireless local area network Wake on Local Area Network World Wide Web Execute Disable Capability Hardware implementation Extended Graphics Array Graphic standard, maximum resolution 1024x768 pixels. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 153: Glossary

    Cache High-speed access buffer for interim storage (buffering) of requested data. CE marking Communauté Européene The CE mark confirms compliance of the product with corresponding EC Directives, for example, with the EMC Directive. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 154 The data are stored in a configuration file and enable the operating system to load the correct device drivers and configure the correct device parameters. . If changes are made to the hardware configuration, the user can change entries in the configuration file using the SETUP program. . SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 155 10/100/1000 Mbps. Execute Disable Capability Hardware implementation that prevents mutual memory accesses by programs and applications. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 156 Intel Active Management Technology This technology permits the diagnostics, management and remote control of PCs. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 157 Legacy Boot Device Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. License key disk The license key disk contains the authorizations or license keys required to enable protected SIMATIC software.
  • Page 158 Recovery function of the USB stick Contains the tools for configuring hard disks and the Windows operating system. Reset Hardware reset: Reset/restart of the PC using a button/switch. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 159 This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. STEP 7 Programming software for the creation of user programs for SIMATIC S7 controllers. Troubleshooting Error cause, cause analysis, remedy SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 160 Wake on Local area network. This function allows the PC to be started via the LAN interface. Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 161: Index

    Creating an image, 93 Factory state, 83 FAQs, 140 FBWF (File Based Write Filter), 56 FCC, 96 Data backup, 93 File Based Write Filter, 56 Data exchange, 42 Firewall, 48 Degree of protection, 105 SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 162 Memory modules, 106 High frequency radiation, 19 Monitoring functions, 49 Recovery function, 81 Motherboard, 106 Repairs, 73 Mounting Restore CD, 87 Modules, 39, 69 Restore function, 82 MUI, 85 Restore function with Windows Embedded Standard, 83 SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 163 Update, 48 Updates Application programs and drives, 93 Operating system, 93, 93 USB 3.0 Interface, 115 User Account Control, 48 UWF, 52 Wall mounting, 33 Warranty, 17 Watchdog, 51 Enable register, 121 Monitoring function, 51 SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...
  • Page 164 Index SIMATIC IPC427E Operating Instructions, 09/2017, A5E37454814-AB...

Table of Contents