hit counter script

Cisco Catalyst 3550 Hardware Installation Manual page 58

Multilayer switch
Hide thumbs Also See for Catalyst 3550:
Table of Contents

Advertisement

Diagnosing Problems
Table 3-2
Common Problems and Their Solutions
Symptom
Poor performance or excessive
errors.
Catalyst 3550 Multilayer Switch Hardware Installation Guide
3-4
Possible Cause
Duplex autonegotiation mismatch.
Cabling distance exceeded.
Port statistics show excessive
frame check sequence (FCS),
late-collision, or alignment
errors.
For 10/100/1000BASE-T
connections:
The distance between the
port and the attached device
exceeds 100 meters.
If the switch is attached to a
repeater, the total distance
between the two end
stations exceeds the cabling
guidelines.
For GBIC port connections:
The distance between the
GBIC port and the attached
device exceeds the GBIC
cabling guidelines.
Bad adapter in attached device.
Excessive errors found in port
statistics.
STP checking for possible
loops.
Chapter 3
Troubleshooting
Resolution
Refer to the Catalyst 3550
Multilayer Switch Software
Configuration Guide for
information on identifying
autonegotiation mismatches.
Refer to the Catalyst 3550
Multilayer Switch Software
Configuration Guide for
information on displaying
port statistics.
Reduce the cable length to
within the recommended
distances.
Refer to your repeater
documentation for cabling
guidelines.
Refer to your GBIC
documentation for cabling
guidelines.
Run adapter card diagnostic
utility.
Wait 30 seconds for the port
LED to turn green.
78-11358-01

Advertisement

Table of Contents
loading

Table of Contents