Description
1.3 Configuration examples
1.3
Configuration examples
1.3.1
TeleControl with SINEMA RC
In this configuration, the remote maintenance master station is a connected to the
Internet/intranet via the SINEMA Remote Connect Server. The stations communicate via
SCALANCE M874 or SCALANCE S615 that establish a VPN tunnel to the SINEMA RC
server. In the master station, the SINEMA RC client establishes a VPN tunnel to the
SINEMA RC server.
The devices must log on to the SINEMA RC server. The VPN tunnel between the device and
the SINEMA RC server is established only after successful authentication. Depending on the
configured communications relations and the security settings, the SINEMA RC server
connects the individual VPN tunnels.
14
SCALANCE S615 Web Based Management
Configuration Manual, 05/2015, C79000-G8976-C388-02