Summary of Contents for Honeywell Experion LX 8 series
Page 1
Experion LX Series 8 Cabinet Installation Instruction EXDOC-X290-en-500A April 2017 Release 500...
Page 2
Honeywell International Sàrl. While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability and fitness for a purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
Contents 1 About this document ..........................5 2 Overview of CE Compliance ........................7 2.1 Related products and modules ..........................8 2.2 Compliance statement and standards used ....................... 10 2.3 Reference to original tested configuration (in cabinet) ..................11 3 Mounting and segregation of wiring ....................13 3.1 Cabling and wiring ............................
1 About this document This document describes how to install and configure the Series 8 cabinet and other important instructions. Revision History Revision Date Description April 2017 Initial release of the document...
2 Overview of CE Compliance Related topics “Related products and modules” on page 8 “Compliance statement and standards used” on page 10 “Reference to original tested configuration (in cabinet)” on page 11...
C300 Controller IOTA, uncoated 8C-TAIXA1 Analog Input IOTA, coated 8U-TAIXA1 Analog Input IOTA, uncoated 8C-TAIXB1 Analog Input redundant IOTA, coated 8U-TAIXB1 Analog Input redundant IOTA, uncoated 8C-TAOXA1 Analog Output IOTA, coated 8U-TAOXA1 Analog Output IOTA, uncoated 8C-TAOXB1 Analog Output redundant IOTA, coated www.honeywell.com...
Page 9
2 OVERVIEW OF CE COMPLIANCE Model number Description 8U-TAOXB1 Analog Output redundant IOTA, uncoated 8C-TDILA1 Digital Input IOTA, coated 8U-TDILA1 Digital Input IOTA, uncoated 8C-TDILB1 Digital Input redundant IOTA, coated 8U-TDILB1 Digital Input redundant IOTA, uncoated 8C-TDODA1 Digital Output IOTA, coated 8U-TDODA1 Digital Output IOTA, uncoated 8C-TDODB1...
Part One consists of general requirements The following standards are used for an EMC directive: Standard Number Standard Name EN 61326-1:2006 Electrical equipment for measurement, control and laboratory use. EMC requirements are Part One of general requirements www.honeywell.com...
2 OVERVIEW OF CE COMPLIANCE 2.3 Reference to original tested configuration (in cabinet) The C300 controller and PGM modules were tested in cabinet. Other modules were tested independently without the benefit of cabinet.
Page 12
2 OVERVIEW OF CE COMPLIANCE www.honeywell.com...
3 Mounting and segregation of wiring This topic describes the mounting and segregation of wiring. Refer to the illustration below for more information: Related topics “Cabling and wiring” on page 14 “Mounting limitations within a cabinet” on page 16...
Determine the maximum cable lengths and the number of drops. Prepare a wiring list. Maintain a blueprint with the location of wiring. Plan for expansion. Plan for diagnostics such as attachment spots for diagnostic tools like a protocol analyzer. See illustration below for more information: www.honeywell.com...
(although this is not normally done). Extension cables are normally used to extend a header board to another cabinet side in a complex. www.honeywell.com...
4 Bonding and grounding This chapter provides more information about bonding and grounding Related topics “Cabinet safety ground connections” on page 18 “Power supply grounding considerations” on page 20...
The following illustration and callout table identifies typical safety ground connections in the cabinet. For Honeywell assembled cabinets, all power and ground connections within the cabinet are made by Honeywell manufacturing. The illustration is not to scale nor are component positions representative of actual mounting locations within the cabinet.
Page 19
4 BONDING AND GROUNDING Figure 2: Typical safety ground connections in cabinet...
It also describes a typical AC power source through the mains panel with a safety ground bus and an AC safety (mains) ground rod. Termination of any required cable shields The shield of the cable must be grounded. www.honeywell.com...
5 Power supply selection and distribution Series 8 system CE Compliance requires the following manufacturers and model power supplies: Manufacturer Model number PULS CPS20.241 MEAN WELL SDR-480P-24 Phoenix TRIO-PS/1AC/24DC/20 Refer to the corresponding manuals of each manufacturer’s for installation limitations. Related topics “Selecting the Power System”...
The power systems provide 24 VDC power to assemblies that are compatible in one or more cabinet sides. Each power system includes the following: • The metal piece that holds power supplies • Two 20A Power Supply 120/240 VAC See illustration below for more information: www.honeywell.com...
5 POWER SUPPLY SELECTION AND DISTRIBUTION 5.2 Power Distribution System The power distribution subsystem consists of the hardware listed in the following table. It distributes 24 VDC from a power system to one or more columns of mounting plates in one or both sides of a cabinet that contains the power system.
Page 24
5 POWER SUPPLY SELECTION AND DISTRIBUTION www.honeywell.com...
6 CE Limitations The following topics provide more information about operating conditions for components, shielded twisted pair (STP) cables and ESD issues. Related topics “Operation environment and shielded wiring” on page 26 “ESD issues” on page 27 “Transient protection required” on page 28...
15 G in 3 axes (shock duration: 11 ms) Shielded wiring required Ethernet cables are used in cabinets to interconnect C300 Controller IOTAs. Only a shielded twisted pair (STP) type cable is used. The use of unshielded twisted pair (UTP) cable is not allowed. www.honeywell.com...
6 CE LIMITATIONS 6.2 ESD issues Static electrical charges Static electricity can influence electronic equipment, and cause equipment malfunctions or damage. The effects may range from momentary glitches to outright failures, data loss, and intermittent failures that are difficult to locate and correct.
EMI. You can see the effectiveness of a particular suppressor by using an oscilloscope to observe the voltage waveform on the line. www.honeywell.com...
7 Maintenance Related topics “C300 controller module and IOTA replacement” on page 30 “PGM Replacement” on page 32 “Series 8 IOTA and I/O module Replacement” on page 34...
Connect the gray I/O LINK cable to IOL1A and IOL1B for IOLINK 1 interface of the controller. Connect the violet IOLINK cable to IOL2A and IOL2B for IOLINK 2 interface of the controller. Install the two-wire twisted pair battery cables onto the Memory Hold Up connector on the left side of the IOTA board. www.honeywell.com...
Page 31
7 MAINTENANCE Insert the controller module onto the IOTA board making sure that the controller circuit board mates properly with the IOTA board connector. Secure the controller module to the IOTA board with two screws located at each side of the plastic cover. The controller will boot-up into an Alive state or a NODB operating state.
The new PGM boots up to Alive or NODB state. Load firmware which is the same version as was running in the old PGM. From Control Builder, perform a Load with Contents to the PGM. www.honeywell.com...
Page 33
7 MAINTENANCE To replace a non-redundant PGM IOTA board On the defective IOTA, loosen the screws at each side of the module cover that secures the PGM to the IOTA board. Loosen the plastic screw on the front of the module cover. Be careful not to strip the plastic screw head. Carefully remove the PGM from the IOTA board and connector.
Carrier with the long screw that is inserted into the hole on the face of the module's plastic cover. The new I/O module boots-up to the Idle state. Load firmware which is the same version as was running in the old controller. www.honeywell.com...
Page 35
7 MAINTENANCE In the Control Builder, perform a Load with Contents. Results <replace with description of results>...
8 Declaration of conformity Please see the attached CE DOC_Series 8 R110.2. Model Number Description Rating 8C-PCNT02 C300 Control Processor, coated 24Vdc, 320mA 8U-PCNT02 C300 Control Processor, 24Vdc, 320mA uncoated 8C-PAIHA1 HART Analog input module, 24Vdc, 110mA coated 8U-PAIHA1 HART Analog input module, 24Vdc, 110mA uncoated 8C-PAINA1...
9 CONCLUSIONS 9.1 Conclusions Refer to the following statement of Honeywell for the compliance of the CE standard: • The SI must provide final judgment regarding the CE Conformity of the assembled cabinet • Honeywell does not take responsibility for the CE Conformity of the assembled cabinet.
Documentation feedback You can find the most up-to-date documents on the Honeywell Process Solutions support website at: http://www.honeywellprocess.com/support If you have comments about Honeywell Process Solutions documentation, send your feedback to: hpsdocs@honeywell.com...
Page 44
CCC visit the website, https://www.honeywellprocess.com/en-US/contact-us/customer-support-contacts/ Pages/default.aspx. Training classes Honeywell holds technical training classes about Experion LX. These classes are taught by experts in the field of process control systems. For more information about these classes, contact your Honeywell representative, or see http://www.automationcollege.com.