Page 2
However, in the course of development of our products we may make changes without notification. Honeywell Elm shall not be liable for errors or for incidental or consequential damages, directly or indirectly, in connection with the furnishing, performance or misuse of this product or document.
Page 3
Universal Controller - EET Generic ZA-10063-EET Product Part No: • Universal Controller * with Elm probes: Issue a : 14/5/97 190887 • Universal Controller ** with PT 1000 probes: 191126 Features: • Controls and monitors HT and LT Generic case •...
Universal Controller - Parameter Range/Units Default Dsgn Act. HT(LT) Generic Cut in Temperature -49 to 30 / °C 0 (-20) ZA-10063-EET Differential Below 0 to 30 / °C 1.5 (2) Issue a : 14/5/97 Air On / Off Weight 0 to 100 / % OT Alarm -49 to 60 / °C 5 (-16)
Page 5
Universal Controller - EET Coldroom ZA-10064-EET Product Part No: • Universal Controller * with Elm probes: 190887 Issue a : 14/5/97 • Universal Controller ** with PT 1000 probes: 191126 Features: Warning ! • Controls and monitors HT and LT Coldroom Before you work on this equipment, isolate the •...
Parameter Range/Units Default Dsgn Act. Universal Controller- HT(LT) Coldroom Cut in Temperature -49 to 30 / °C 0 (-20) ZA-10064-EET Differential Below 0 to 30 / °C 1.5 (2) Issue a : 14/5/97 Air On / Off Weight 0 to 100 / % OT Alarm -49 to 60 / °C 5 (-16)
Page 7
Universal Controller - EET 3 Range ZA-10065-EET Product Part No: Issue a : 14/5/97 • Universal Controller * with Elm probes: 190887 • Universal Controller ** with PT 1000 probes: 191126 Features: Warning ! • Controls and monitors HT and LT 3 Range case •...
Universal Controller - 3 Range ZA-10065-EET Parameter Range/Units Default Dsgn Act. HT(LT) Issue a : 14/5/97 Red Cycle Temperature 1 to 7 / °C 4 (-22) Red OT Alarm Temp. 7 to 10 / °C 8 (-15) Commissioning: Red UT Alarm Temp. -3 to 4 / °C 2 (-30) Yellow Cycle Temperature...
Page 9
Universal Controller - EET Full Glass Door ZA-10066-EET Product Part No: Issue a : 14/5/97 • Universal Controller * with Elm probes: 190887 • Universal Controller ** with PT 1000 probes: 191126 Features: Warning ! • Controls and monitors HT and LT Full Glass Door case Before you work on this equipment, isolate the •...
Universal Controller - F/G Door Parameter Range/Units Default Dsgn Act. HT(LT) ZA-10066-EET Cut in Temperature -49 to 30 / °C 0 (-20) Issue a : 14/5/97 Differential Below 0 to 30 / °C 1.5 (2) Air On / Off Weight 0 to 100 / % OT Alarm -49 to 60 / °C...
Page 11
Universal Controller - EET ST Case ZA-10067-EET Product Part No: Issue a : 14/5/97 • Universal Controller * with Elm probes: 190887 • Universal Controller ** with PT 1000 probes: 191126 Features: Warning ! • Controls and monitors High Temp. and Low Temp. ST case •...
Universal Controller - ST Case Output Connections (Fig. 3): The diagram on the left shows the output ZA-10067-EET connections to the EEV and suction line valves, Issue a : 14/5/97 SGV or defrost heater, lights, blinds and alarm. The connection to the EPR valve is made from Commissioning: the front panel, at the two-pin connector Lights...
Universal Controller - EET ST Coldroom ZA-10068-EET Product Part No: • Universal Controller * with Elm probes: 190887 Issue a : 14/5/97 • Universal Controller ** with PT 1000 probes: 191126 Features: Warning ! • Controls and monitors High Temp. and Low Temp. ST Coldroom Before you work on this equipment, isolate the •...
Universal Controller- ST Coldroom ZA-10068-EET Issue a : 14/5/97 Output Connections (Fig. 3): The diagram on the left shows the output Commissioning: connections to the EEV and suction line valves, SGV, defrost heater, drip pan heater, remote, 1. Check all electrical connections (Figs. 2 and alarm.