hit counter script
Download Print this page
Honeywell R6H911RF Applications Manual

Honeywell R6H911RF Applications Manual

2-zone application 2x t6r smart thermostat & 2-channel receiver box

Advertisement

Quick Links

2
T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX
X
FEATURES
T6R Smart Thermostat
Attractive, ultra-modern styled thermostats make it ideal for
any location in any type of home.
Wireless with table stand to fit a new and retrofit
installations.
Wi-Fi communication to connect to the Internet
- Smart Home and Apple HomeKit ready
A dynamic text display on the LCD that gives enhanced
feedback to the user / installer.
High LCD Contrast and backlighting for easier viewing in all
light conditions.
Time out screen with selectable brightness
Factory programmed daily or 5+2 default heating schedule.
Schedule with up to 6 independent time and temperature
pairs to suit the comfort needs.
"Hold until" temperature override of programmed schedule
temperature till the next switch point.
Schedule off mode for manual operation.
Setpoint and room temperature always displayed.
OFF position has an integral frost protection setting at
minimum 5C so that pipes in the house will never freeze in
winter.
Alert messages to assist in fault-finding.
Honeywell Home mobile App for:
- Remote view and change of settings
- Schedule changes
- Smartphone Geolocation temperature control
2-zone application
With the new 2-channel Receiver box (R6H911RF) and
2x a T6R wireless smart thermostats (
automatic time and temperature control of 2 heating
zones and a boiler for homes and apartments can be
managed.
It's compatible with 24-230V on/off and OpenTherm®
appliances such as gas boilers, combi-boilers and heat
pump. Also works with zone valve applications but not
with electric heating (240V).
The solution is designed with the installer in mind.
The 2-channel Receiver box offers mounting options for
directly on the wall or on a wall box. Wiring can be from
below or from the back by lifting the terminal platform,
which makes installation quick and easy.
The T6R wireless thermostat has a high contrast PMVA
display with dynamic text line and touch screen buttons.
The thermostat has a simple programming philosophy to
make it easier to install and very user friendly.
The 2-zone solution is ideal for consumers who want to
split the comfort control of their home in 2 areas, like
upstairs and down-stairs or a living and working area.
The solution offers remote comfort control of both zones
via the Honeywell Home app.
User menu allows extra functions to be set at the discretion
of the user:
- Language selection
- Wi-FI setup
- Optimisation
- Clock setting
- Resetting the heating program to factory default
- Brightness
- Temperature offset
- Lock function
Advanced menu (Installer Set-Up) allows extra functions to
be set at the discretion of the installer to match the
consumers applications and needs:
- System type
- OpenTherm data
- Upper / Lower Set point Limit Adjust
- Minimum ON time
- Cycle rate
- Factory Reset
- Binding
2-channel Receiver box
Clear LED indication of bound devices
Override button per zone with LED indication
Simple binding via override button
A flip up wiring platform for easy wiring
Pinhole for easy reset.
2 on/off relay outputs
OpenTherm
®
compatible heating control output.
APPLICATION MANUAL
T6H700RW)
T6R-2Z-EN0H 8603 NL01 R0718

Advertisement

loading

Summary of Contents for Honeywell R6H911RF

  • Page 1 2-zone application T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX APPLICATION MANUAL With the new 2-channel Receiver box (R6H911RF) and 2x a T6R wireless smart thermostats ( T6H700RW) automatic time and temperature control of 2 heating zones and a boiler for homes and apartments can be managed.
  • Page 2 2 ZONE T6R SMART THERMOSTAT T6R THERMOSTAT DISPLAY/BUTTON LAYOUT Schedule period Reference to the icons: 2-CHANNEL RECEIVER BOX INTERFACE T6R-2Z-EN0H 8603 NL01 R0718...
  • Page 3 2 ZONE T6R SMART THERMOSTAT WIRING OPTIONS 2-CHANNEL RECEIVER BOX The 2-channel Receiver box always requires 230V power and is suitable for both 24V and 230V zone valve applications. Note: For the wiring of the OpenTherrm® boiler a separate cable is required. A) Wiring 2 zone valves (230V) and basic B) Wiring 2 zone valves (230V) and OpenTherm ®...
  • Page 4 2 ZONE T6R SMART THERMOSTAT MOUNTING AND WIRING 2-CHANNEL RECEIVER BOX To ensure your safety, always make sure mains power is switched OFF before accessing wiring. Find a suitable location near the boiler. Leave at least 30cm distance from any metal objects including wall boxes and boiler housing.
  • Page 5 2 ZONE T6R SMART THERMOSTAT T6R THERMOSTAT SET UP AND BINDING Choose the appropriate plug. Zone 1 Thermostat powering up, setup and binding Both the T6R Smart Thermostats still need to be bound to the 2-channel Receiver box before they can control the comfort in their zone.
  • Page 6 Thermostat is switched OFF to setup using the Honeywell App is currently unsupported) Zone 2 Thermostat powering up, setup and binding Now place the second zone thermostat near the 2-channel Receiver box and plug-in the adapter.
  • Page 7 Thermostat is switched OFF to setup using the Honeywell App is currently unsupported) After binding the second zone the binding and setup is complete. Place both thermostats on an even and horizontal surface in their appropriate area (zone) to control the comfort.
  • Page 8: Advanced Menu

    2 ZONE T6R SMART THERMOSTAT ADVANCED MENU To enter the Advanced menu (installer set-up): Press the menu key for 5 seconds. Menu item Default Options Language English English, Francais, Espanol, Deutsch, Nederlands, Italiano OpenTherm OpenTherm boiler data when a vailable (see OpenTherm communication) Cycle rate 3,6,9 or 12 Min on time...
  • Page 9 2 ZONE T6R SMART THERMOSTAT OPENTHERM® COMMUNICATION OpenTherm® is a manufacturer independent communication protocol between modulating appliances (boilers, air heaters and heat recovery units) and room thermostats. Via the OpenTherm® protocol, the Receiver box of the T6 / T6R thermostat constantly communicates with the connected appliance.
  • Page 10 2 ZONE T6R SMART THERMOSTAT HEAT DEMAND CONTROL The control of the heat demand of the 2 zones depends on the applied boiler type. An on/off boiler or an OpenTherm® modulating boiler can be applied. The 2-channel Receiver box receives from both zone thermostats the heat demand and will control the corresponding zone valve via the relay contact to open.
  • Page 11: Specifications

     method  Class VI (+4%), (EU) 811/2013   IEEE 802.11b/g/n – 2.4GHz Wi-Fi Honeywell, declares that this thermostat is in compliance  100mW Max. power with the essential requirements and other relevant provisions of Directive 2014/53/EU DIMENSIONS RECEIVER BOX...
  • Page 12: Troubleshooting

    T6R Wireless Smart Thermostat (spare) All packaging contains 6 languages: English, Dutch, R6H911RF4018 5025121381130 2-channel Receiver box R6 wireless French, German, Italian and (spare) Spanish Honeywell Control Systems Limited Newhouse Industrial Estate Motherwell ML1 5SB United Kingdom T6R-2Z-EN0H 8603 NL01 R0718...

This manual is also suitable for:

T6h700rw