Message and Recovery Procedures
Error Message DOT1X-4-PROC_START_ERR: Dot1x unable to start.
Explanation
Recommended Action
global configuration command. If this message recurs, reload the device.
Error Message DOT1X-4-UNKN_ERR: An unknown operational error occurred.
Explanation
Recommended Action
Error Message DOT1X-5-ERR_CHANNELLING: Dot1x cannot be enabled on Channelling ports.
Explanation
occurred because the switch tried to set IEEE 802.1x port control to auto or to force-unauthorized
mode on the channel port, which is not allowed.
Recommended Action
IEEE 802.1x authentication.
Error Message DOT1X-5-ERR_DYNAMIC: Dot1x cannot be enabled on Dynamic ports.
Explanation
occurred because the switch tried to set IEEE 802.1x port-control to auto or force-unauthorized
mode on a dynamic mode port, which is not allowed.
Recommended Action
authentication.
Error Message DOT1X-5-ERR_MULTI_ACCESS: Dot1x can not be enabled on voice vlan
configured ports.
Explanation
This occurred because the switch tried to set IEEE 802.1x port control to auto or
force-unauthorized mode on a voice VLAN- configured port, which is not allowed.
Recommended Action
authentication.
Error Message DOT1X-5-ERR_PROTO_TUNNELLING: Dot1x can not be enabled on protocol
tunnelling enabled ports.
Explanation
port. This condition was caused by trying to set IEEE 802.1x port-control to auto or
force-unauthorized mode on a protocol tunneling enabled port, which is not allowed.
Recommended Action
operation.
OL-12191-01
The system failed to start the IEEE 802.1x process.
Restart the IEEE 802.1x process by entering the dot1x system-auth-control
The IEEE 802.1x process cannot operate because of an internal system error.
Reload the device.
IEEE 802.1x authentication could not be enabled on the EtherChannel port. This
Disable the EtherChannel on the interface and then try to re-enable
IEEE 802.1x authentication could not be enabled on the dynamic-mode port. This
Disable dynamic mode on the interface, and then try IEEE 802.1x
IEEE 802.1x authentication could not be enabled on the voice VLAN- configured port.
Disable the voice VLAN on the interface, and then try IEEE 802.1x
IEEE 802.1x authentication could not be enabled on the protocol tunneling enabled
Disable protocol tunnelling on the interface, and retry the IEEE 802.1x