Actual control can be carried out by setting registers
from F0F00800 onward.
ddd indicates the control value expressed as a 12 bit
hexadecimal number.
xxx indicates that any setting made will be ignored.
Brightness control
Address
Data
F0F00800
82000ddd
Gamma control
Address
Data
F0F00818
82000000
82000mmn
Shutter (exposure time) control
Address
Data
F0F0081C
82000ddd
C2000xxx
F0F00978h
Determines
(To obtain
the optional
this address,
value using
see "The
the 32-bit
formula for
floating-
absolute
point format.
value shutter
control
register
address" on
page 22.)
Gain control
Address
Data
F0F00820
82000ddd
Trigger control
Address
Data
F0F00830
82000000
82010000
82E00000
F0F0062C
80000000
Trigger Delay control
Address
Data
F0F00834
82000ddd
22
Adjusts the black level.
Sets Gamma to OFF.
n: 1h to Fh (1 to 16) gamma
curve n×0.1 equivalent
mm: 00h to FFh (0 to 255)
gamma curve starting position
Controls shutter using the
manually set relative value.
Controls shutter using the
manually set absolute value.
After F0F0081C has been set
to the absolute value control,
set the exposure time using
this register.
Set Gain manually.
Sets to Hardware Trigger
Mode0.
Sets to Hardware Trigger
Mode1.
Sets to Software Trigger
Mode0.
Outputs a software trigger.
Automatically resets to 0 when
exposure ends.
Sets Trigger Delay.
Pan control
Address
Data
F0F00884
82000ddd
GPIO control
Address
Data
F0F20400
0000000d
F0F20404
Strobe control
Address
Data
F0F20200
80000000
82000000
82dddwww
The formula for absolute value
shutter control register address
Absolute value shutter control CSR offset
address
Address
Data
F0F0071C
003C025C
The register address for absolute value shutter control is
given by the following formula.
F0000000h + 003C025Ch
Address
Data
F0F00970
3727C5AC
F0F00974
41800000
F0F00978
The data is indicated by 32-bit floating-point format.
3727C5AC is 0.00001, and 41800000 is 1.
Sets Pan manually.
Outputs a signal to the output
port.
bit31: GPO1
bit30: GPO2
Reads out the status of the
input port.
bit31: GPI1
bit30: GPI2
A strobe signal is not output.
Outputs an exposure signal.
ddd = delay, www = signal
width, unit = µs.
Absolute value shutter control
CSR offset.
4 = F0F00970h
×
Absolute value shutter control
minimum value. (ReadOnly)
Absolute value shutter control
maximum value. (ReadOnly)
Absolute value shutter control
setting value.