8.2.5

Dimension drawing

Figure 8-22
Dimension drawing of Safe Brake Relay, all data in mm and (inches)
8.2.6

Mounting

PM240-2 FSA to FSC Power Modules
● Mount the Safe Brake Relay at the rear of the cabinet next to the Power Module.
PM240-2 FSD to FSF Power Modules
● Mount the Brake Relay at the rear of the lower shield plate.
● Attach the Brake Relay before you install the shield plate.
8.2.7

Technical data

Table 8- 24
Technical data
6SL3252-0BB01-0AA0
Power supply
Current requirement, max.
Motor brake
at 24 V DC
Conductor cross section, max.
Dimensions (W x H x D)
Weight
AC Drive
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
Supplementary system components and encoder system integration
Unit
V
20.4 ... 28.8
DC
Recommended nominal value of the power supply 26 V DC
(to equalize and compensate for the voltage drop along the feeder
cable to the 24 V DC solenoid of the motor brake)
A
2
A
0.05 + current requirement of the motor brake
mm
2.5
2
mm
69 x 63 x 33
kg
approx. 0.17