Easy Extend
8.7 Description of the script language
Example
<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE AGM>
<AGM>
<DEVICE>
<NAME> Device 1 </NAME>
<START_UP>
...
</START_UP>
<SET_ACTIVE>
...
</SET_ACTIVE>
<SET_INACTIVE>
...
</SET_INACTIVE>
<TEST>
...
</TEST>
</DEVICE>
...
</AGM>
8.7.3
CONTROL_RESET
Description
This identifier allows one or more control components to be restarted. Execution of the script
is only continued when the control has resumed cyclic operation.
Programming
Identifier:
Syntax:
Attributes:
204
CONTROL_RESET
<CONTROL_RESET resetnc="TRUE" />
resetnc="true"
resetdrive="true"
Identifier for Easy Extend
Identifier for the device
Identifier for commissioning the device
Identifier for activating the device
Identifier for deactivating the device
Identifier for testing the device
The NC component is restarted.
The drive components are restarted.
Commissioning Manual, 02/2012, 6FC5397-3DP40-3BA0