3 Setting up functions
3.4 Fault services
Function
Force absolute
address
Add icon
Absolute
address
Data type
Comment
Add
"PLC Trigger" tab
The comparison operation can be edited under "PLC Trigger".
Function
PLC triggers
Trigger 1
Trigger 2
...
Trigger n
3-132
Description
To make it necessary for the trigger logic
operations and comparison operations to be
manipulated by deleting entries that have
already been made (for testing purposes)
each individual address can be forced, i.e.
the address does not participate in the AND
logic operation of the trigger.
Deletes an absolute address and the associ-
ated comparison operation.
Entry of the address of a PLC variable via
STEP 7 syntax.
All simple file types are supported.
Note:
The addresses can be entered in German
and English notation, e.g. E1.1 or I1.1
Enters a comment for the absolute address.
Adds the edited address to the AND logic
operation of the trigger conditions.
Notice:
The comparison operation must be entered
separately. ePS Network Services permits
saving without a comparison operation; this
renders the trigger ineffective.
Description
Shows the comparison operations for the
AND logic operations in the trigger, which
can also be edited
The comparison operations for Trigger 1 and
Trigger 2 are logic OR.
The comparison operation consists of the
comparison operation (>, <, =, <>) and the
fixed comparison value (digit).
Notice:
ePS Network Services will not check the
plausibility of the variable address for the
potential comparison operation and actual
comparison value.
ePS Network Services, Function Manual (FH) - 03/2012
Type
SELECTION
SELECTION
INPUT
DISPLAY
INPUT
DISPLAY
INPUT
ACTION
Type
TAB
DISPLAY
INPUT
INPUT
DISPLAY
© Siemens AG 2012 All Rights Reserved