8.6

Process

Temperature
- Maximum surface temperature
- CE and General Purpose
- FM/ATEX Hazardous
- CSA Class II Group E, F
- CSA Class II Group G
- Maximum surface temperature
Pressure
Note
The device construction allows over-pressure between -0.2 and 0.1 bar in hazardous areas.
This product is designated as a Pressure Accessory per Directive 2014/68/EU and is not
intended for use as a safety device.
Materials of construction are chosen based on their chemical compatibility (or inertness) for
general purposes. For exposure to specific environments, check with chemical compatibility
charts before installing.
26
Standard model
High temperature option
Standard model
High pressure options
WARNING
WARNING
-25 ... +80 °C (-13 ... +176 °F)
CSA temperature code: T5
120 ºC (248 ºF) [ATEX relevant]
-25 ... +600 °C (-13 ... +1 112 °F)
-25 ... +250 °C (-13 ... +482 °F)
-25 ... +195 °C (-13 ... +383 °F), CSA tempera-
ture code: T2D
-25 ... +160 °C (-13 ... +320 °F), CSA tempera-
ture code: T3B
250 °C (482 °F)
Max. 0.8 bar, gauge (11.6 psi, gauge)
Max. 5 bar, gauge (72.5 psi, gauge)
Max. 10 bar, gauge (145 psi, gauge)
Operating Instructions, 04/2019, A5E34210883-AB