TB51x-TB54x — 1 TB51x-TB54x ● TB511-ARCNET ● TB511-ETH ● TB511-ETH-XC ● TB521-ARCNET ● TB521-ETH ● TB521-ETH-XC ● TB523-2ETH ● TB541-ETH ● TB541-ETH-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! –...
TB51x-TB54x Disassembly XC Version XC = eXtreme Conditions Extreme conditions Terminal bases for use in extreme ambient conditions have no sign for XC version. The figure 3 in the Part No. 1SAP3... (label) identifies the XC version. 1.1 Assembly 1.2 Disassembly 3ADR024117M02xx, 11, en_US 2019/02/27...
TB51x-TB54x Dimensions 1.3 Assembly with Screws NOTICE! Damage to the modules without using wall mounting accessory! Wall mounting accessories (TA526) prevent bending and damaging the modules during assembly with screws. Inserting the wall mounting accessories TA526 is mandatory. TA526 are snapped on the rear side of the module like DIN rails. One TA526 is turned by 180°.
TB51x-TB54x Connection > Power Supply 1.5 Connection I/O bus Slot for processor module Slots for communication modules Interface for FieldBusPlug, not for terminal base TB523-2ETH Power supply 24 VDC Serial interface COM1 Network interfaces: TB5xx-ETH: Ethernet, TB5xx-ARCNET: ARCNET TB5x1: Serial interface COM2, TB523-2ETH: second Ethernet network interface Holes for wall mounting 1.5.1 Power Supply Pin Assignment...
TB51x-TB54x Connection > Serial Interface COM2 1.5.2 Serial Interface COM1 Pin assignment Signal Interface Description Terminator P RS-485 Terminator P RxD/TxD-P RS-485 Receive/Transmit, positive RxD/TxD-N RS-485 Receive/Transmit, negative Terminator N RS-485 Terminator N RS-232 Request to send (output) Terminal RS-232 Transmit data Terminal block...
TB51x-TB54x Connection > Fieldbus-neutral Interface 1.5.4 ARCNET Network Interface ARCNET connection of the processor modules PM5xx-ARC. 1.5.5 Ethernet Network Interface Pin Assignment Signal Description TxD+ Transmit Data + TxD- Transmit Data - RxD+ Receive Data + Not used Not used RxD- Receive Data - Not used...
TB51x-TB54x Recycling 1.6 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 1.7 Certification 1.8 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
TB56xx-2ETH — 2 TB56xx-2ETH ● TB5600-2ETH ● TB5600-2ETH-XC ● TB5610-2ETH ● TB5610-2ETH-XC ● TB5620-2ETH ● TB5620-2ETH-XC ● TB5640-2ETH ● TB5640-2ETH-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! –...
TB56xx-2ETH Disassembly XC Version XC = eXtreme Conditions Extreme conditions Terminal bases for use in extreme ambient conditions have no sign for XC version. The figure 3 in the Part No. 1SAP3... (label) identifies the XC version. 2.1 Assembly 2.2 Disassembly 2019/02/27 3ADR024117M02xx, 11, en_US...
TB56xx-2ETH Dimensions 2.3 Assembly with Screws NOTICE! Damage to the modules without using wall mounting accessory! Wall mounting accessories (TA526) prevent bending and damaging the modules during assembly with screws. Inserting the wall mounting accessories TA526 is mandatory. TA526 are snapped on the rear side of the module like DIN rails. One TA526 is turned by 180°.
TB56xx-2ETH Connection > CAN Interface 2.5 Connection I/O bus Slot for processor module Slots for communication modules Interface for CAN Power supply 24 VDC Serial interface COM1 Ethernet network interfaces Holes for wall mounting 2.5.1 CAN Interface Pin Assignment Interface Signal Description CAN_GND...
TB56xx-2ETH Connection > Serial Interface COM1 NOTICE! Unused connector! Make sure that the terminal block is always connected to the terminal base, even if you do not use the interface. 2.5.2 Power Supply Pin Assignment Pin Assignment Label Function Description +24 VDC Positive pin of the power supply voltage...
TB56xx-2ETH Certification 2.5.4 Ethernet Network Interface Pin Assignment Signal Description TxD+ Transmit Data + TxD- Transmit Data - RxD+ Receive Data + Not used Not used RxD- Receive Data - Not used Not used Shield Cable shield Functional earth NOTICE! Risk of corrosion! Unused connectors and slots may corrode if XC devices are used in salt-mist environments.
TB56xx-2ETH Recycling 2.8 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
Page 24
PM5xx (-y) CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g. EN 60204-1. –...
PM5xx (-y) Cleaning 3.4 Connection Status displays (7-segment) Triangle displays for ”Item” Square displays for ”Status” Status LEDs Function keys MC: Slot for the SD Memory Card TA525: Label The connection part may be different on various terminal base types. See installation instructions of the specific terminal base suitable for this CPU for connection specifications.
PM5xx (-y) Recycling 3.6 Certification 3.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
PM595 — 4 PM595 ● PM595-4ETH-F ● PM595-4ETH-M-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
PM595 Connection 4.4 Connection I/O bus for connection of I/O modules 2x 5 LEDs to display the states of the fieldbuses Cover for battery and display 5 LEDs to display the states of the processor module 5 LEDs (reserved) 2x2 RJ45 interfaces for fieldbuses Slot for memory card Reset button Button (reserved)
PM595 Connection > Serial Interface COM2 4.4.1 Power Supply Pin Assignment Pin Assignment Label Function Description +24 VDC Positive pin of the power supply voltage +24 VDC Positive pin of the power supply voltage Negative pin of the power supply voltage Terminal block Terminal block removed...
PM595 Cleaning Serial Signal Interface Description Interface +5 V 5 V supply out RS-232 Receive data Input RxD/TxD-N RS-485 Receive/Transmit Negative RS-232 Clear to send Input Shield Functional earth NOTICE! Risk of corrosion! Unused connectors and slots may corrode if XC devices are used in salt-mist environments.
PM595 Recycling 4.6 Certification 4.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
PM56xx-2ETH — 5 PM56xx-2ETH ● PM5630-2ETH ● PM5630-2ETH-XC ● PM5650-2ETH ● PM5650-2ETH-XC ● PM5670-2ETH ● PM5670-2ETH-XC ● PM5675-2ETH ● PM5675-2ETH-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! –...
PM56xx-2ETH Connection 5.4 Connection Status displays (7-segment) Triangle displays for ”Item” Square displays for ”Status” Status LEDs Function keys MC: Slot for the SD Memory Card TA525: Label The connection part may be different on various terminal base types. See installation instructions of the specific terminal base suitable for this CPU for connection specifications.
PM56xx-2ETH Recycling 5.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 5.6 Certification 5.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
CM582-DP — 6 CM582-DP ● CM582-DP ● CM582-DP-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
CM582-DP Connection 6.4 Connection The connection part may be different on various terminal base types. See installation instructions of the specific terminal base suitable for this CPU for connection specifications. 5 LEDs for state display Label Interface for PROFIBUS TA524 Dummy Communication Module Sign for XC version 3ADR024117M02xx, 11, en_US 2019/02/27...
CM582-DP Certification 6.4.1 Interface for PROFIBUS Pin Assignment Signal Description Not connected Not connected RxD/TxD-P Receive/Transmit positive CNTR-P Control signal for repeater, positive DGND Reference potential for data exchange and +5 V +5 V (power supply for the bus termi- nating resistors) Not connected RxD/TxD-N...
CM582-DP Recycling 6.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
CM589-PNIO(-4) — 7 CM589-PNIO(-4) ● CM589-PNIO ● CM589-PNIO-XC ● CM589-PNIO-4 ● CM589-PNIO-4-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
CM589-PNIO(-4) Connection 7.4 Connection The connection part may be different on various terminal base types. See installation instructions of the specific terminal base suitable for this CPU for connection specifications. 5 LEDs for state display 2 rotary switches for setting the I/O device identifier Label Ethernet network interfaces TA524 Dummy Communication Module...
CM589-PNIO(-4) Certification 7.4.1 Ethernet Network Interface Pin Assignment Signal Description TxD+ Transmit data + TxD- Transmit data - RxD+ Receive data + Not used Not used RxD- Receive data - Not used Not used Shield Cable shield Functional earth In corrosive environment, please protect unused connectors using the TA535 accessory.
CM589-PNIO(-4) Recycling 7.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
TU5xx — 8 TU5xx ● ① TU515 24 VDC ● ① TU531 230 VAC ● ① TU541 24 VDC ● ② TU516(-XC) 24 VDC ● ② TU532(-XC) 230 VAC ● ② TU542(-XC) 24 VDC ● ③ TU516-H(-XC) 24 VDC ● ③...
Page 54
TU5xx Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 55
TU5xx Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
TU5xx Assembly XC Version XC = eXtreme Conditions Extreme conditions Terminal units for use in extreme ambient conditions have no sign for XC version. The figure 4 in the Part No. 1SAP4... (label) identifies the XC version. 8.1 Assembly 3ADR024117M02xx, 11, en_US 2019/02/27...
TU5xx Assembly with Screws 8.2 Disassembly 8.3 Assembly with Screws NOTICE! Damage to the modules without using wall mounting accessory! Wall mounting accessories (TA526) prevent bending and damaging the modules during assembly with screws. Inserting the wall mounting accessories TA526 is mandatory. TA526 is snapped on the rear side of the module like DIN rails.
TU5xx Cleaning 8.5 Connection Fig. 1: TU516 for example I/O bus (10 pins, male) to electrically connect the previous terminal unit, the CPU terminal base or the communication interface module to the terminal unit I/O bus (10 pins, female) to electrically connect other terminal units 3a Plug (2x 25 pins) to electrically connect the inserted I/O modules 3b For TU515, TU516(-H)(-XC), TU541 and TU542(-H)(-XC): Plug (2x 19 pins) to electrically connect the inserted I/O modules...
TU5xx Recycling 8.7 Certification 8.8 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
TU582-S — 9 TU582-S ● TU582-S 24 VDC ● TU582-S-XC 24 VDC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
TU582-S Dimensions 9.3 Assembly with Screws NOTICE! Damage to the modules without using wall mounting accessory! Wall mounting accessories (TA526) prevent bending and damaging the modules during assembly with screws. Inserting the wall mounting accessories TA526 is mandatory. TA526 is snapped on the rear side of the module like DIN rails. Fasten module with screws (M4, max 1.2 Nm) from the front side.
TU582-S Connection The dimensions are in mm and in brackets in inch. 9.5 Connection I/O bus (10 pins, male) to electrically connect the previous terminal unit, the CPU terminal base or the communication interface module to the terminal unit I/O bus (10 pins, female) to electrically connect other terminal units Plug (1x 50 pins and 2x 57 pins) to electrically connect the inserted I/O modules With a screwdriver inserted in this place, the terminal unit and the adjacent terminal unit can be shoved from each other...
TU582-S Recycling 9.6 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 9.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
DC522 — 10 DC522 ● DC522 ● DC522-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 67
DC522 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 68
DC522 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
DC522 Connection 10.4 Connection I/O bus Allocation between terminal number and signal name Sensor power supply 24 VDC / 0.5 A 16 yellow LEDs to display the signal states at the digital inputs/outputs (C0 - C15) 1 green LED to display the state of the process supply voltage UP 4 red LEDs to display errors Label Terminal unit...
DC522 Cleaning 10.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 10.4.2 Inputs/Outputs Example Example for connection as an input Example for connection as an output 10.5 Cleaning Cleaning instruction...
DC522 Recycling 10.6 Certification 10.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
DC523 — 11 DC523 ● DC523 ● DC523-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 75
DC523 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 76
DC523 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
DC523 Connection 11.4 Connection I/O bus Allocation between terminal number and signal name Sensor power supply 24 VDC / 0.5 A 24 yellow LEDs to display the signal states at the digital inputs/outputs (C0 - C23) 1 green LED to display the state of the process supply voltage UP 4 red LEDs to display errors Label Terminal unit...
DC523 Cleaning 11.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 11.4.2 Inputs/Outputs Example Example for connection as an input Example for connection as an output 11.5 Cleaning Cleaning instruction...
DC523 Recycling 11.6 Certification 11.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
DC532 — 12 DC532 ● DC532 ● DC532-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 83
DC532 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 84
DC532 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
DC532 Connection 12.4 Connection I/O bus Allocation between terminal number and signal name 16 yellow LEDs to display the signal states at the digital inputs (I0 - I15) 16 yellow LEDs to display the signal states at the digital outputs (C16 - C31) 1 green LED to display the state of the process supply voltage UP 4 red LEDs to display errors Label...
DC532 Connection > Inputs/Outputs 12.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 12.4.2 Inputs Example Fig. 2: Example for connection input Ix 12.4.3 Inputs/Outputs 3ADR024117M02xx, 11, en_US 2019/02/27...
DC532 Recycling Example Example for connection as an input Example for connection as an output 12.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 12.6 Certification 12.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
DI524 — 13 DI524 ● DI524 ● DI524-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 91
DI524 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 92
DI524 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
DI524 Connection 13.4 Connection I/O bus Allocation between terminal number and signal name 32 yellow LEDs to display the signal states at the digital inputs I0 to I31 1 green LEDs to display the states of the process supply voltage UP 4 red LEDs to display errors Label Terminal unit...
DI524 Cleaning 13.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 13.4.2 Outputs Example Fig. 3: Example for connection input Ix 13.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead.
DI524 Recycling 13.6 Certification 13.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
DI581-S — 14 DI581-S ● DI581-S ● DI581-S-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
DI581-S Connection 14.4 Connection I/O bus System LED Allocation between terminal number and signal name 16 yellow/red LEDs to display the signal states of the digital inputs I0 to I15 8 Test pulse outputs T0 to T7 2 rotary switches for setting the PROFIsafe address 1 green LED to display the state of the process supply voltage UP 2 red LEDs to display errors Label...
DI581-S Connection > Inputs 14.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 14.4.2 Inputs Example Fig. 4: Example for connection input Ix AC500-S Safety User Manual For a detailed description of the electrical connection of the module, please refer to the "AC500-S Safety User Manual".
DI581-S Recycling 14.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 14.6 Certification 14.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
DO524 — 15 DO524 ● DO524 ● DO524-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 105
DO524 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 106
DO524 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
DO524 Connection 15.4 Connection I/O bus Allocation between terminal number and signal name 32 yellow LEDs to display the signal states at the digital outputs (O0 to O31) 1 green LEDs to display the state of the process supply voltage UP 4 red LEDs to display errors Label Terminal unit...
DO524 Certification 15.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 15.4.2 Outputs Example Fig. 5: Example for connection output 15.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead.
DO524 Recycling 15.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
DO526 — 16 DO526 ● DO526 ● DO526-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 113
DO526 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 114
DO526 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
DO526 Connection 16.4 Connection I/O bus Allocation between terminal number and signal name 8 yellow LEDs to display the signal states of the outputs O0 to O7 3 green LEDs to display the states of the process supply voltage UP, UP3 and UP4 2 red LEDs to display errors Label Terminal unit...
DO526 Cleaning 16.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 16.4.2 Outputs Example Fig. 6: Example for connection output 16.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead.
DO526 Recycling 16.6 Certification 16.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
DX522 — 17 DX522 ● DX522 ● DX522-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 121
DX522 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 122
DX522 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
DX522 Connection 17.4 Connection I/O bus Allocation between terminal number and signal name 8 yellow LEDs to display the signal states at the digital inputs (I0 - I7) 8 yellow LEDs to display the signal states at the digital relay outputs (R0 - R7) 1 green LED to display the state of the process supply voltage UP 2 red LEDs to display errors Label...
DX522 Connection > Outputs 17.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 17.4.2 Inputs Example Fig. 7: Example for connection input 17.4.3 Outputs If the relay outputs have to switch inductive DC loads, free-wheeling diodes must be circuited in parallel to these loads.
DX522 Recycling If the relay outputs have to switch inductive AC loads, spark suppressors are required. 17.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 17.6 Certification 17.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
DX531 — 18 DX531 ● DX531 CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g. EN 60204-1. –...
Page 129
DX531 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 130
DX531 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
DX531 Connection 18.4 Connection I/O bus Allocation between terminal number and signal name 8 yellow LEDs to display the signal states at the digital inputs (I0 - I7) 4 yellow LEDs to display the signal states at the digital relay outputs (R0 - R3) 1 green LED to display the state of the process supply voltage UP 2 red LEDs to display errors Label...
DX531 Connection > Outputs 18.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 18.4.2 Inputs 18.4.3 Outputs If the relay outputs have to switch inductive DC loads, free-wheeling diodes must be circuited in parallel to these loads.
DX531 Recycling 18.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 18.6 Certification 18.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
DX581-S — 19 DX581-S ● DX581-S ● DX581-S-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
DX581-S Connection 19.4 Connection I/O bus System LED Allocation between terminal number and signal name 8 yellow/red LEDs to display the signal states of the digital inputs I0 to I7 4 Test pulse outputs T0 to T3 8 yellow/red LEDs to display the signal states of the digital outputs O0 to O7 2 rotary switches for setting the PROFIsafe address 1 green LED to display the state of the process supply voltage UP 2 red LEDs to display errors...
DX581-S Connection > Inputs/Outputs 19.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 19.4.2 Inputs/Outputs Examples Fig. 8: Example for connection input Ix 3ADR024117M02xx, 11, en_US 2019/02/27...
DX581-S Certification Fig. 9: Example for connection output Ox AC500-S Safety User Manual For a detailed description of the electrical connection of the module, please refer to the "AC500-S Safety User Manual". 19.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead.
DX581-S Recycling 19.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
AI523 — 20 AI523 ● AI523 ● AI523-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 144
AI523 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 145
AI523 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
AI523 Connection 20.4 Connection I/O bus Allocation between terminal number and signal name 16 yellow LEDs to display the signal states at the analog inputs (I0 - I15) 1 green LED to display the state of the process supply voltage UP 2 red LEDs to display errors Label Terminal unit...
AI523 Connection > Inputs 20.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 20.4.2 Inputs Example Fig. 10: Example for connection input 2019/02/27 3ADR024117M02xx, 11, en_US...
AI523 Recycling 20.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 20.6 Certification 20.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
AI531 — 21 AI531 ● AI531 ● AI531-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 152
AI531 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 153
AI531 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
AI531 Connection 21.4 Connection I/O bus Allocation between terminal number and signal name 4 yellow LEDs to display the states at the inputs (I0 - I3) 4 yellow LEDs to display the states at the inputs (I4 - I7) 1 green LED to display the state of the process supply voltage UP 2 red LEDs to display errors Label Terminal unit...
AI531 Connection > Inputs 21.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 21.4.2 Inputs 2019/02/27 3ADR024117M02xx, 11, en_US...
AI531 Certification Example Fig. 11: Example for connection input 21.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 21.6 Certification 3ADR024117M02xx, 11, en_US 2019/02/27...
AI531 Recycling 21.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
AI581-S — 22 AI581-S ● AI581-S ● AI581-S-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
AI581-S Connection 22.4 Connection I/O bus System LED Allocation between terminal number and signal name 4 yellow/red LEDs to display the signal states of the analog inputs 2 rotary switches for setting the PROFIsafe address 1 green LED to display the state of the process supply voltage UP 2 red LEDs to display errors Label Terminal unit TU582-S(-XC)
AI581-S Connection > Inputs 22.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 22.4.2 Inputs Example Fig. 12: Example for connection input AC500-S Safety User Manual For a detailed description of the electrical connection of the module, please refer to the "AC500-S Safety User Manual".
AI581-S Recycling 22.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 22.6 Certification 22.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
AO523 — 23 AO523 ● AO523 ● AO523-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 167
AO523 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 168
AO523 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
AO523 Connection 23.4 Connection I/O bus Allocation between terminal number and signal name 16 yellow LEDs to display the signal states at the analog outputs (O0 - O15) 1 green LED to display the state of the process supply voltage UP 2 red LEDs to display errors Label Terminal unit...
AO523 Connection > Outputs 23.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 23.4.2 Outputs Example Fig. 13: Example for connection output 3ADR024117M02xx, 11, en_US 2019/02/27...
AO523 Recycling 23.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 23.6 Certification 23.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
AX521 — 24 AX521 ● AX521 ● AX521-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 175
AX521 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 176
AX521 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
AX521 Connection 24.4 Connection I/O bus Allocation between terminal number and signal name 4 yellow LEDs to display the signal states at the analog inputs (I0 - I3) 4 yellow LEDs to display the signal states at the analog outputs (O0 - O3) 1 green LED to display the state of the process supply voltage UP 2 red LEDs to display errors Label...
AX521 Connection > Outputs 24.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 24.4.2 Inputs Example Fig. 14: Example for connection input 24.4.3 Outputs 3ADR024117M02xx, 11, en_US 2019/02/27...
AX521 Recycling Example Fig. 15: Example for connection output 24.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 24.6 Certification 24.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
AX522 — 25 AX522 ● AX522 ● AX522-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 183
AX522 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 184
AX522 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
AX522 Connection 25.4 Connection I/O bus Allocation between terminal number and signal name 8 yellow LEDs to display the signal states at the analog inputs (I0 - I7) 8 yellow LEDs to display the signal states at the analog outputs (O0 - O7) 1 green LED to display the state of the process supply voltage UP 2 red LEDs to display errors Label...
AX522 Connection > Outputs 25.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 25.4.2 Inputs Example Fig. 16: Example for connection input 25.4.3 Outputs 3ADR024117M02xx, 11, en_US 2019/02/27...
AX522 Recycling Example Fig. 17: Example for connection output 25.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 25.6 Certification 25.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive.
DA501 — 26 DA501 ● DA501 ● DA501-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 191
DA501 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 192
DA501 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
DA501 Connection 26.4 Connection I/O bus Allocation between terminal number and signal name 16 yellow LEDs to display the signal states of the digital inputs DI0 - DI15 4 yellow LEDs to display the signal states of the analog inputs AI0 to AI3 2 yellow LEDs to display the signal states of the analog outputs AO0 to AO1 8 yellow LEDs to display the signal state of the configurable digital inputs/outputs DC16 to DC23...
DA501 Connection > Inputs/Outputs 26.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 26.4.2 Inputs/Outputs Examples Fig. 18: Example for connection input DIx Fig. 19: Example for connection input AIx 3ADR024117M02xx, 11, en_US 2019/02/27...
DA501 Certification Fig. 20: Example for connection output AOx Example for connection as an input Example for connection as an output 26.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 26.6 Certification 2019/02/27 3ADR024117M02xx, 11, en_US...
DA501 Recycling 26.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
CD522 — 27 CD522 ● CD522 ● CD522-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
CD522 Connection 27.4 Connection I/O bus Allocation between terminal number and signal name 3 yellow LEDs to display the signal states of the encoder 0 input 3 yellow LEDs to display the signal states of the encoder 1 input 2 green LEDs to display the 5-V-power-supply states 2 yellow LEDs to display the signal state of the digital input I3 and I11 8 yellow LEDs to display the input/output signal states 2 yellow LEDs to display the signal states of the PWM/pulse outputs...
CD522 Connection > Inputs 27.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 27.4.2 Inputs Example Example for connection input Ix 2019/02/27 3ADR024117M02xx, 11, en_US...
CD522 Connection > Outputs 27.4.3 Inputs/Outputs Example Example for connection as an input Example for connection as an output 27.4.4 Outputs Push-pull outputs 3ADR024117M02xx, 11, en_US 2019/02/27...
CD522 Certification Example Example for connection as output with UP reference Example for connection as output with ZP reference Examples for connection encoder/sensors, see description CD522. 27.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 27.6 Certification 2019/02/27...
CD522 Recycling 27.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
CI5x1 — 28 CI5x1 ● CI501-PNIO ● CI501-PNIO-XC ● CI511-ETHCAT ● CI521-MODTCP ● CI521-MODTCP-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 208
CI5x1 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 209
CI5x1 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
CI5x1 Assembly NOTICE! The section "Hot Swap" is only valid for CI501-PNIO(-XC) and CI521-MODTCP(-XC). 28.1 Assembly 3ADR024117M02xx, 11, en_US 2019/02/27...
CI5x1 Connection 28.4 Connection Fig. 21: CI501-PNIO (example ) I/O bus Allocation between terminal number and signal name 6 yellow LEDs to display the signal states of the analog inputs/outputs (AI0 - AI3, AO0 - AO1) 8 yellow LEDs to display the signal states of the digital inputs (DI0 - DI7) 8 yellow LEDs to display the signal states of the digital outputs (DO0 - DO7) 2 green LEDs to display the supply voltage UP and UP3 3 red LEDs to display errors (CH-ERR1, CH-ERR2, CH-ERR3)
CI5x1 Connection > Inputs/Outputs 28.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 28.4.2 Inputs/Outputs Example Analog Input Fig. 22: Example for connection input AIx 2019/02/27 3ADR024117M02xx, 11, en_US...
CI5x1 Certification Example Analog Output Fig. 23: Example for connection output AOx Example Digital Input Fig. 24: Example for connection input DIx Example Digital Output Fig. 25: Example for connection output DOx 28.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead.
CI5x1 Recycling 28.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
CI5x2 — 29 CI5x2 ● CI502-PNIO ● CI502-PNIO-XC ● CI512-ETHCAT ● CI522-MODTCP ● CI522-MODTCP-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 217
CI5x2 Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 218
CI5x2 Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
CI5x2 Assembly NOTICE! The section "Hot Swap" is only valid for CI502-PNIO(-XC) and CI522-MODTCP(-XC). 29.1 Assembly 2019/02/27 3ADR024117M02xx, 11, en_US...
CI5x2 Connection 29.4 Connection Fig. 26: CI502-PNIO (example ) I/O bus Allocation between terminal number and signal name 8 yellow LEDs to display the signal states of the configurable digital inputs/outputs (DC0 - DC7) 8 yellow LEDs to display the signal states of the digital inputs (DI8 - DI15) 8 yellow LEDs to display the signal states of the digital outputs (DO8 - DO15) 2 green LEDs to display the supply voltage UP and UP3 3 red LEDs to display errors (CH-ERR1, CH-ERR2, CH-ERR3)
CI5x2 Connection > Inputs/Outputs 29.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 29.4.2 Inputs/Outputs Example Input or Output Example for connection as an input Example for connection as an output 3ADR024117M02xx, 11, en_US 2019/02/27...
CI5x2 Recycling Example Digital Input Fig. 27: Example for connection input DIx Example Digital Output Fig. 28: Example for connection output DOx 29.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 29.6 Certification 29.7...
CI541-DP — 30 CI541-DP ● CI541-DP ● CI541-DP-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 225
CI541-DP Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 226
CI541-DP Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
CI541-DP Connection 30.4 Connection I/O bus Allocation between terminal number and signal name 6 yellow LEDs to display the signal states of the analog inputs/outputs (AI0 - AI3, AO0 - AO1) 8 yellow LEDs to display the signal states of the digital inputs (DI0 - DI7) 8 yellow LEDs to display the signal states of the digital outputs (DO0 - DO7) 2 green LEDs to display the supply voltage UP and UP3 3 red LEDs to display errors (CH-ERR1, CH-ERR2, CH-ERR3)
CI541-DP Connection > Inputs/Outputs 30.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 30.4.2 Inputs/Outputs Example Analog Input Fig. 29: Example for connection input AIx 3ADR024117M02xx, 11, en_US 2019/02/27...
CI541-DP Certification Example Analog Output Fig. 30: Example for connection output AOx Example Digital Input Fig. 31: Example for connection input DIx Example Digital Output Fig. 32: Example for connection output DOx 30.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead.
CI541-DP Recycling 30.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.
CI542-DP — 31 CI542-DP ● CI542-DP ● CI542-DP-XC CAUTION! Risk of injury and damaging the product! Improper installation and maintenance may result in injury and can damage the product! – Installation and maintenance have to be performed according to the technical rules, codes and relevant standards, e.g.
Page 234
CI542-DP Hot Swap H = Hot swap Hot swap Preconditions for hot swapping I/O modules: – Hot-swappable terminal units have the appendix TU5xx-H. – I/O modules as of index F0. – Communication interface modules CI5xx as of index F0. The index of the module is in the right corner of the label. NOTICE! Risk of damage to I/O modules! Modules with index below F0 can be damaged when inserted or removed from...
Page 235
CI542-DP Device Min. required device index for I/O module as of FW Version 3.0.14 DO573, FM562, DI572 DO526 DC562 DO562 DO526 (-XC) CD522 (-XC) DO524 (-XC) AI531 DA501 (-XC), DI524 (-XC), DC532 (-XC), DC523 (-XC), DC522 (-XC), AX521 (-XC), AO523 (-XC), AI523 (-XC), AX522 (-XC), AI531-XC,...
CI542-DP Connection 31.4 Connection I/O bus Allocation between terminal number and signal name 8 yellow LEDs to display the signal states of the configurable digital inputs/outputs (DC0 - DC7) 8 yellow LEDs to display the signal states of the digital inputs (DI8 - DI15) 8 yellow LEDs to display the signal states of the digital outputs (DO8 - DO15) 2 green LEDs to display the supply voltage UP and UP3 3 red LEDs to display errors (CH-ERR1, CH-ERR2, CH-ERR3)
CI542-DP Connection > Inputs/Outputs 31.4.1 Process Supply Voltage CAUTION! The process supply voltage must be included in the earthing concept (e. g. earthing of the minus pole). 31.4.2 Inputs/Outputs Example Input or Output Example for connection as an input Example for connection as an output 2019/02/27 3ADR024117M02xx, 11, en_US...
CI542-DP Certification Example Digital Input Fig. 33: Example for connection input DIx Example Digital Output Fig. 34: Example for connection output DOx 31.5 Cleaning Cleaning instruction Do not use cleaning agent for cleaning the device. Use a damp cloth instead. 31.6 Certification 3ADR024117M02xx, 11, en_US...
CI542-DP Recycling 31.7 Recycling Disposal and recycling information This symbol on the product (and on its packaging) is in accordance with the European Union's Waste Electrical and Electronic Equipment (WEEE) Directive. The symbol indicates that this product must be recycled/disposed of separately from other household waste.