hit counter script
Download Print this page
HP A3550A Installation Manual

HP A3550A Installation Manual

Battery backup unit bbu, 20-slot disk arrays
Hide thumbs Also See for A3550A:

Advertisement

Quick Links

Hewlett-Packard Battery Backup Unit (BBU)
Installation Guide (20-slot Disk Arrays)
Hewlett-Packard BBUs are customer installable and replaceable. A replacement BBU must be the same type as the BBU
being replaced.
The locations of the BBUs in the 20-slot disk arrays are shown in Figure 1.
.
Install or replace a BBU by performing the following steps. Place a check in the appropriate
Step 1:
Observe antistatic precautions
A BBU is shipped with an ESD kit containing:
ESD wrist strap
ESD conductive sheet
Ground the ESD wrist strap to any unplated metal on
the disk array chassis and fasten the strap to your wrist.
Step 2:
Prepare to install the BBU
Remove the new BBU from its shipping carton and
place it on a suitable antistatic surface or the ESD
conductive sheet.
Open the fan pack by sliding the LOCK/UNLOCK switch
to the UNLOCK position and carefully swinging the fan
pack open.
The BBU can be installed or replaced with array power on.
The installation or replacement
fan pack closed within two minutes to avoid a thermal shut-
down.
All manuals and user guides at all-guides.com
BBU
20-slot deskside and rackmount disk arrays (rear view)
(shown with fan packs removed for clarity)
be completed and the
Figure 1.
Step 3: Install the BBU
Locate the slot where the BBU is to be installed (Figure
1) and remove the failed BBU or the BBU filler panel if
present (Figure 2). To remove the BBU, slide the black
latches toward the center of the unit and extract the
BBU.
Install the BBU as shown in Figure 2.
Push the BBU into the disk array chassis until the
latches on the BBU lock and audible clicks are heard.
When the latches are locked, the BBU cannot be pulled
out again without using the latches.
as the step is completed.

Advertisement

loading

Summary of Contents for HP A3550A

  • Page 1 All manuals and user guides at all-guides.com Hewlett-Packard Battery Backup Unit (BBU) Installation Guide (20-slot Disk Arrays) Hewlett-Packard BBUs are customer installable and replaceable. A replacement BBU must be the same type as the BBU being replaced. The locations of the BBUs in the 20-slot disk arrays are shown in Figure 1. 20-slot deskside and rackmount disk arrays (rear view) (shown with fan packs removed for clarity) Figure 1.
  • Page 2 All manuals and user guides at all-guides.com Squeeze the latches toward the center of the BBU Remove or install Figure 2. For more information on BBU installation procedures and Close the fan pack by carefully swinging the fan pack recharge times, see the closed and firmly pressing it onto the latch and sliding the LOCK/UNLOCK switch to the LOCK position.