Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The
notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage
have no safety alert symbol. These notices shown below are graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of
injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with
the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their
training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products
and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage,
installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any
problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.
© Siemens AG 2009 - 2013. All rights reserved
J31069-D0214-U001-A4-7618, 10/2013
1

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC RF382R Scanmode

  • Page 1 WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 2: Ordering Data

    MOBY D, RF200, RF300, RF600 and only in combination with third-party devices and components recommended and/or approved by Siemens. See also SIMATIC RF300 System Manual (http://support.automation.siemens.com/WW/view/en/21738946) Mounting on metal The RF382R can be mounted directly on metal. Flush mounting on metal is not permitted.
  • Page 3: Transmission Window

    D ≥ 200 mm Transmission window Orientation of magnetic fields of the SIMATIC RF382R Scanmode For many applications it may be best to operate the reader so that the tags move from left to right (or from right to left) at a certain distance in front of the narrow edge of the reader.
  • Page 4 Distance from the reader edge at which maximum horizontal main field length L exists Operating range in the main field Limit distance ① Level 1 ② Level 2 ③ Level 3 ⇒ Direction of motion of the transponder SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 5 Maximum length of the main field, horizontal magnetic field Distance from the reader edge at which maximum horizontal main field length L exists Operating range in the main field Limit distance = 13 mm ⇓ Direction of motion of the transponder SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 6 (8 bytes) Field data of transponders and readers The following tables show the field data of transponders with SIMATIC RF382R Scanmode. The technical specifications listed below are typical data and apply at an ambient temperature of +22 °C. Tolerances of ±20% are admissible due to production and temperature conditions.
  • Page 7 MDS D160 to MDS D324 to MDS D424 to MDS D460 to MDS D460 MDS D124 MDS D160 MDS D324 MDS D424 Horizontal main field Vertical main field The minimum distance can be undershot in multitag mode. SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 8 If this is the case, this reply data of the transponder is lost for the application. In addition to this, the acknowledgment, for example of "Read parameter" is corrupted by transponder data. SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 9 1st byte 2nd byte 20th byte 21st byte 0x01 0x00 Para Para Para Para "Change parameters retentively" telegram: Command Status Quantity 1st byte 2nd byte 20th byte 21st byte 0x01 0x01 Para Para Para Para SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 10 The transferred value provides information about how well a tag is positioned in, or passes through, the reader's HF field. "Activate test mode" telegram: Command Status Quantity 1st byte 2nd byte 20th byte 21st byte 0x03 0x01 0xxx 0xxx 0xxx 0xxx Acknowledge Command Error code 0x03 SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 11 Parity bit setting - applies to scan mode, test mode, and telegram communication only UID "Data record" parameter only user data Combination of data that the reader automatically transfers to the host in scan mode UID and user data SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 12 RF310R, the parameter values or the default values are read out as described in the "Parameters" table. 22+23 V xx.yy Firmware version '1' .. '9' ASCII characters Hardware version V x.y FPGA version SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 13 DVD "RFID Systems, Software & Documentation" or on the Internet using the following links: SIMATIC RF MANAGER Basic V3.0 (http://support.automation.siemens.com/WW/view/en/64700331) SIMATIC RF MANAGER Basic V3.0 Service Pack 1 (http://support.automation.siemens.com/WW/view/en/78473837) Reader parameter assignment Proceed as follows to set parameters for the RF382R Scanmode reader: 1.
  • Page 14 Reaction: A new project window opens. 5. Set the required parameters in the "Properties" area. 6. Click the icon in the toolbar to transfer the data to the reader. With the icon, you can display the read transponders SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 15: Technical Specifications

    Data cable length RS-422: max. 1000 m Data cable length RS-232: max. 30 m Read distances of the reader Refer to the section Field data of transponders and readers (Page 6) Minimum distance between two RF382R Scanmode readers 200 mm SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 16 Weight approx. 550 g MTBF (Mean Time Between Failures) 1 x 10 Approvals Radio to R&TTE guidelines EN 300 330, EN 301489, CE Current consumption typ. 140 mA Max. power consumption (DC input) 3.5 W SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 17: Dimension Drawing

    (2) This device must accept any interference received, including interference that may cause undesired operation. Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. SIMATIC RF382R Scanmode J31069-D0214-U001-A4-7618, 10/2013...
  • Page 18 C22.2 No. 60950 (I.T.E) or acc. to UL508 and C22.2 No. 142 (IND.CONT.EQ) Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.