Name
Function
H501
BUS_SYNC
H502
BUS_FAULT
H505
Temperature alarm (red) Lights up
7.3.1

Mounting

Installation
The module can be attached at a suitable position via the four mounting holes (e.g. behind the
machine control panel or in the control cabinet). The selection of the appropriate mounting
position depends on the interfaces used and the associated maximum cable lengths.
Four standard torx-slotted screws T20/M4 are used to attach the module.
MCP Interface PN dimension drawing
Figure 7-23
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
Status
Meaning
Does not light
No PROFINET communication.
up
Lights up
PROFINET is synchronized (STOP state).
Flashes (0.5
PROFINET is synchronized (RUN state).
Hz)
Lights up
PROFINET group fault.
At least one temperature limit is being exceeded.
MCP Interface PN dimension drawing
Connectable components
7.3 MCP Interface PN
133