Adapt the necessary system–specific parameters as
required (e.g. the input/output terminals, monitoring
functions, optimization)
Write into the FEPROM (P0652 = 1)
and wait until writing has been completed (P0652 = 0)
Fig. 4-4
Commissioning using the display and operator unit (Part 2 of 3)
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
4.4
Commissioning using the display and operator unit
1
from the previous page
"_ _ _ run"
is displayed
(cyclic operation)
Is an unlisted
motor being
used?
no
Remove write protection (P0651 = 4)
Values
changed?
yes
Save the parameters in the FEPROM
End
(cyclic operation)
4 Commissioning
Unlisted motor:
(refer under the index entry
"Unlisted motor – what is
one")
yes
continue on the next
2
page
no
4