4 Repair
4.4.1 Removing the cable harness
Continued
7
Removing the cable harness in the lower arm
1
2
254
Action
Use caution and pull out the cable harness
through the hole in the frame.
Tip
Keep a hand on the cable protection while
pulling out the cable harness from the
base, so it does not come loose.
Action
Loosen the axis-2 lower arm metal clamp
and the axis-3 lower arm metal clamp loc-
ated on the inside of the lower arm by re-
moving the attachment screws.
Note
The screws are reached from the outside
of the lower arm.
Use caution and pull the cable harness out.