Summary of Contents for Canon imageRUNNER ADVANCE C2030 Series
Page 1
How to Check this Installation Procedure Checking the Contents When using the parts included in the package [1] Cassette Pedestal X 1 [2] Connecting Fixture X 1 A symbol is described on the illustration in the case of using the parts included in the package of this product.
Checking the Contents Unpacking Although pictures and illustrations of imageRUNNER ADVANCE C2030/C2020 Series are 1) Turn OFF the main power switch of the host machine. used in this procedure, the procedure is the same in the case of models other than the series. Installation Outline Drawing F-1-5 2) Open the plastics, and remove the 2 pads by lifting the rear of the equipment.
Installation Procedure 3) Remove the remaining 2 pads and plastics by lifting the front of the equipment. 1) Open the Right Lower Cover. CAUTION: If mounting the host machine without opening the Right Lower Cover, the cover may get damage. Plastic F-1-7 4) Lift the equipment down from pallet.
Page 4
CAUTION: 3) Mount the host machine by aligning the corners (right and left) of the front side of the host • Be sure to perform the work in accordance with the standard to handle a heavy load machine with the corners (right and left) of the front side of the equipment. in each country.
Page 5
[imageRUNNER ADVANCE C2030/2025/C2020 Series] 4) Press the cassette release button, and remove the Cassettes 2 and 3. Button F-1-13 5) Attach the Connecting Fixture. • 1 Screw (RS Tightening; M3x8.5) • 1 Boss CAUTION: When attaching the Connecting Fixture, be sure the attaching direction Models other than imageRUNNER ADVANCE imageRUNNER ADVANCE...
Page 6
[Models other than imageRUNNER ADVANCE C2030/C2020 Series] 8) Remove the Connector Cover of the host machine. (The removed Connector Cover will not NOTE: be used.) Hook the [A] part of the Connecting Fixture on the plate [B] on the host machine side, •...
Page 7
9) Connect the 3 connectors to the host machine and put the cables through the guides. Loosen the screw on the Connector Cover included in the package, and install the grounding wire between it and the toothed washer. CAUTION: Be sure to tuck the extra slack of the harness to the host machine side to prevent the Screw cables from being trapped.
NOTE: Install the Connector Cover. • When installing the host machine at the same time, be sure to follow "Unpacking and • 1 W Sems Screw (Use the screw removed in step 8.) Installation" in the Installation Procedure Manual. • When installing this equipment later, be sure to follow the following procedure.
Page 9
2) Hold the lever of the Side Guide Plate, and adjust the plate to the specified size. At this 6) Cut the 2 places of the Size Plates with nippers. time, move the Side Guide Plate by referring to the Size Index (Label) of the sheet size to be set, and adjust the Side Guide Plate to the click position (position where it clicks).
Page 10
Adjustment 3) Hold the lever of the Trailing Edge Guide Plate, and check the values of the scale on the 2 Adjustment Plates of the Trailing Edge Guide Plate. [imageRUNNER ADVANCE C2030/C2020 Series] NOTE: The 2nd side of 2-sided print mentioned later means 2nd side in the image formation order.
Page 11
5) Move the Adjustment Plates back and forth according to the scale values checked in step 6) Tighten the Fixation Screws. 3. As the Adjustment Plate is moved toward the rear by 1 scale, the left edge margin is 7) Return the cassette to its original position. decreased by 1mm.
Margin Adjustment (2nd side) [Models other than imageRUNNER ADVANCE C2030/ C2020 Series] 1) Execute duplex printing from the Cassette 3, and check that the left edge margin is within 2.5 Auto Adjust Gradation +/- 2.0mm. Feed direction 1) Clean the Copyboard Glass surface of the host machine. of paper 2) Set A3, A4, 11x17, or LTR size papers in a cassette.
Image Position Adjustment ■ Left Edge Margin Adjustment (2nd side) ■ Left Edge Margin Adjustment (1st side) NOTE: By executing the margin adjustment (2nd side) for the Cassette 1, the adjustment is Adjustment of Cassette/Manual feed pickup tray applied to all source of paper. Print from each cassette/Manual feed pickup tray, and check that the left edge margin of the image (L1) is within 2.5 +/- 1.5mm.
Page 14
■ Leading Edge Margin Adjustment (1st side) NOTE: By executing the leading edge margin adjustment for the Cassette 1, the adjustment is applied to all source of paper. Execute printing from the Cassette 1, and check that the leading edge margin is within L1=2.5 +/- 1.5mm.