hit counter script

Management Switch Option Settings; Cn1610 Switch Option Settings - IBM System Storage N Series Setup And Configuration Manual

Clustered data ontap switch
Hide thumbs Also See for System Storage N Series:
Table of Contents

Advertisement

Required network information for management switches
Port e0M is allocated as the management port on supported platforms. The
management port assignments for the various controllers are:
v Port e0f and the remote LAN module (RLM) on N7600, N7700, N7800, and
v Port e0d and the RLM on N5300 and N5600 systems
v Port e0M or the service port (wrench icon) on N32xx, N60xx, N62xx, N7550T,
Note: The node management logical interface (LIF) resides on a single port on a
node and uses a single port on a switch by default. The node management LIF
does not fail over to other ports on the node in the same manner that the data and
cluster LIFS do. For more information about how to configure the node
management LIF for failover, see Network Management Guide and the Data ONTAP
8.2 Clustered Data ONTAP Release Notes.

Management switch option settings

This table shows the management switch settings that can be modified and set on
your management switch on site.

CN1610 switch option settings

The CN1610 switch ships with settings that were made by IBM, including the
FASTPATH software default values.
This table shows the CN1610 switch settings as set by IBM, the FASTPATH default
settings, and option settings that can be modified on site. Some of the settings are
6
IBM System Storage N series: Clustered Data ONTAP Switch Setup and Configuration Guide
1
Management switch A
2
To node 1
3
To cluster switch A
4
RJ-45 10/100/1000 Mbps
5
Inter switch link
6
Console
7
Customer network
8
Management switch B
9
To node 2
10
To cluster switch B
11
Cluster switch A
N7900 systems
and N7950T systems
Management switch option settings
Option
Link aggregation
MTU
MSTP
12
Nodes to cluster
13
10 Gb SFP+
14
Nodes to cluster
15
ISL
16
To management switch A port 13
17
Cluster switch B
18
Node 1
19
To management switch B port 13
20
Node 2
21
To management switch A port 1
22
To management switch B port 2
Setting configuration
on for inter-switch links
MTU for management switch on all ports to
1518
on

Advertisement