Page 1
™ NetworX Series NX-216E Zone Expander Module Installation and Startup...
Page 2
GE Security. This document contains proprietary information of GE Security and is furnished to its customer solely to assist that customer in the installation, testing, operations, and/or maintenance of the equipment described.
TABLE OF CONTENTS GENERAL DESCRIPTION ..........................4 ORDERING INFORMATION......................... 4 III. BOARD INSTALLATION ..........................4 WIRING ................................5 TERMINAL DESCRIPTION........................... 5 DIP SWITCH SETTINGS (6 POSITION) ...................... 6 VII. ENROLLING THE EXPANDER ........................7 VIII. DEFAULT ZONE CONFIGURATIONS ......................7 ZONE CONFIGURATION AND PARTITION .....................
Fire Supervision Module NX-003C Commercial Burglar Enclosure These wireless devices are UL listed for residential applications only. Please refer to the GE Security product catalog for warranty details. BOARD INSTALLATION III. Inside the can, several 2-holed insertion points have been constructed. This allows for either vertical or horizontal placement of the modules.
WIRING Any unused zones must have the EOL resistor across it (unless all eight are disabled by dip switch 6). Figure IV—1 TERMINAL DESCRIPTION Connect to the KP POS terminal of the NetworX control panel (refer to Compatibility chart on the back of this manual).
DIP SWITCH SETTINGS (6 position) The first thing that must be decided is the starting zone of this particular zone expander. The starting zone must be on a boundary of eight (8) zones. The sixteen (16) zones for this module will move out from this starting position. To set the starting zone, set the dip switch according to the table below: THE POSITION OF ALL SWITCHES IS ONLY UPDATED WHEN THE NX-216E IS POWERED UP.
ENROLLING THE EXPANDER VII. The NetworX control panels have the ability to automatically find and store in memory the presence of all keypads, zone expanders, wireless receivers and any other module connected to the data terminal. (Refer to Compatibility chart on the back of this manual). This allows these modules to be supervised by the control panel. To enroll the modules enter the Program Mode of the control panel (refer to the installation manual for the specific control panel).
Page 8
DATA DESCRIPTION OF DEFAULT CONFIGURATION ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip will start entry delay 1. This zone will bypass when the "Group Bypass" command is entered at the keypad. The lack of a trip during exit delay will enable the Automatic Bypass or Instant mode if so programmed. INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED - This zone will be instant when the system is armed and no entry or exit delays are being timed.
ZONE CONFIGURATION AND PARTITION The programming for all zone information is performed in the NetworX control panels (refer to Compatibility chart on the back of this manual). For instructions on accessing and programming the control panel as well as changing the characteristics of a configuration group, refer to the installation manual for the corresponding control panel.
PROGRAMMING WORKSHEETS DESCRIPTION DEFAULT DATA ZONES 9 - 16 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 9 - 16 PARTITION SELECT Segment Zone ZONES 17 – 24 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 17 – 24 PARTITION SELECT Segment Zone ZONES 25 – 32 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 25 –...
Page 11
DESCRIPTION DEFAULT DATA ZONES 41 – 48 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 41 – 48 PARTITION SELECT Segment Zone NOTE: THE FOLLOWING LOCATIONS ARE ONLY AVAILABLE ON THE NX8-E PANELS ZONES 49 – 56 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 49 – 56 PARTITION SELECT Segment Zone ZONES 57 –...
Page 12
DESCRIPTION DEFAULT DATA ZONES 73 – 80 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 73 – 80 PARTITION SELECT Segment Zone ZONES 81 – 88 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 81 – 88 PARTITION SELECT Segment Zone ZONES 89 – 96 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 89 –...
Page 13
DESCRIPTION DEFAULT DATA ZONES 105 – 112 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 105 – 112 PARTITION SELECT Segment Zone ZONES 113 – 120 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 113 – 120 PARTITION SELECT Segment Zone ZONES 121 – 128 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 121 –...
Page 14
DESCRIPTION DEFAULT DATA ZONES 137 – 144 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 137 – 144 PARTITION SELECT Segment Zone ZONES 145 – 152 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 145 – 152 PARTITION SELECT Segment Zone ZONES 153 – 160 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 153 –...
Page 15
DESCRIPTION DEFAULT DATA ZONES 169 – 176 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 169 – 176 PARTITION SELECT Segment Zone ZONES 177 – 184 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 177 – 184 PARTITION SELECT Segment Zone ZONES 185 – 192 CONFIGURATION GROUP 6-6-6-6-6-6-6-6 ZONES 185 –...
SHIPPING WEIGHT 2 lbs. COMPATIBLE CONTROL PANELS: NETWORX PANEL MAX NX-216E MODULES MAX ZONE COUNT NX-8 NX-8E Main 800-727-2339 Technical Support 888-437-3287 Outside the US 903-845-6941 Sales & Literature 800-547-2556 Main Fax 903-845-6811 Web: www.ge-security.com INX216EIM Rev F (January 2009)