Key to symbols and safety instructions ▶ Do not operate any electrical Key to symbols and safety appliances or switches (on/off). instructions ▶ Extinguish other sources of ignition. Explanation of symbols ▶ Go to a different location and call the gas supplier or an authorised Warnings technician.
Page 4
Key to symbols and safety instructions Combustion air and surrounding air ▶ Handing these instructions to customer. ▶ To avoid corrosion, the combustion air and surrounding air must be free from harmful substances (e.g. THIS APPLIANCE IS NOT FOR USE AS A halogenated hydrocarbons which POOL OR SPA POOL HEATER.THIS contain chlorine and fluorine...
Technical Characteristics and Dimensions • Gas flow adjustment proportional to the water flow to Technical Characteristics and maintain a constant temperature. • Safety devices: Dimensions – Ionisation probe to check for accidental extinction of the burner flame General Description – Flue gas safety device which turns off the heater in The appliance has been AS/NZS 5263.1.2 tested.
Technical Characteristics and Dimensions Dimensions Fig. 1 [1] Front cover [8] Gas connection [2] Opening in rear panel for mounting on the wall [9] Connection collar for flue [3] Temperature/volume selector [10] Draught diverter [4] Gas adjustment [11] Copper Heat exchanger [5] Digital display [12] Burner [6] Switch/LED - Low water pressure indicator...
Technical Characteristics and Dimensions Functional diagram of the heater 6720608992-05.1V Fig. 2 Functional diagram [1] Pilot burner [17] Diaphragm [2] Ignition Electrode [18] Main gas valve [3] Ionisation probe [19] Maximum gas adjusting screw [4] Heat exchanger [20] Gas supply pipe [5] Main burner [21] Gas filter [6] Injector...
Regulations Technical characteristics Technical characteristics Units GWH10 GWH13 GWH16 Gas Consumption Nominal Gas Consumption 100 (NG) 97 (LP gas) Supply pressure Natural gas H 1.13 1.13 1.13 LP gas 2.75 2.75 2.75 Number of injectors Water data Maximum permissible pressure 1000 1000 1000...
Installation substances: halogenated hydrocarbons contained in This appliance should only be installed in solvents, paints, glues, hairsprays and various domestic applications where cold water temperature detergents. If necessary, take adequate measures. does not exceed 40 °C. • Install the appliance in accordance with the minimum installation clearances indicated in Fig.NOT DEFINED.
Installation Water connection DANGER: Make sure that all flue connections It is advisable to purge the water pipes before connection, are sealed. because the presence of dirt may reduce the flow and, in ▶ Fit the flue pipe with an approved flue cowl. extreme cases, cause a blockage.
Installation Gas connection DANGER: If local regulations are not followed, a fire or explosion could result causing property damage, personal injury, or loss of life. Size gas supply as per AS5601. Incorrect gas pipe sizing will not be covered by the warranty.
Operating instructions Operating instructions Turning the heater on and off Open all water and gas isolation valves. Turning on Purge the pipes. ▶ Press the switch , position CAUTION: The front stainless steel panel in the burner and pilot burner area may reach high temperatures, with risk of burning in case of contact, and must not be removed.
Operating instructions Gas adjustment Regulating the temperature to the minimum required value reduces energy consumption. Lower water temperature. Use less gas. CAUTION: The temperature on the display is not precise, always check before bathing children or elderly people. Draining the appliance There are two ways to drain the appliance if there is a risk of freezing.
Page 15
Operating instructions ▶ Drain all the water contained in the heater. Fig. 15 Draining [1] pressure relief screw 6 720 608 992 (2018/01)
Commissioning Commissioning Inlet pressure adjustment ▶ Turn on the heater with the gas selector set to the left (maximum position). DANGER: The following procedures must only be performed by a qualified technician. Burner pressures have been adjusted in the factory, however adjustment may be required upon installation.
Remove the pipe and recommend the appliance be maintained on an annual basis. replace the flue pipe. These jobs can only be done by a Bosch authorised service * These procedures must be performed by a qualified installer/ agent.
Problems Problems Problem/cause/solution Assembly, maintenance and repairs must be performed by qualified technicians only. The following chart offers solutions to possible problems. Problem Cause Solution The heater does not ignite and digital Switch turned off. Check switch position. display is turned off. Slow and difficult ignition of the burner.
Bosch warranty would not apply. strictly observed. We use the best possible technology and materials, under economic considerations, to protect the Water quality table environment.
Page 20
1. Warranty of the hot water unit. Bosch offers, at its option, to repair or exchange this Bosch hot water unit or the relevant part listed in clause 2 below at no 4. Warranty conditions charge, if it becomes faulty or defective in manufacture or (a) Proof of purchase may be required.
Page 21
Purpose. A customer can object at any time to the use of their personal information for the Purpose. Bosch will cease to use a customer's personal information accordingly if an objection is made.