hit counter script

Dimensions - Bosch GWH 10-2 G Series Installation Manual And Operating Instructions

Hide thumbs Also See for GWH 10-2 G Series:
Table of Contents

Advertisement

Technical Characteristics and Dimensions
2.5

Dimensions

Fig. 1
[1] Front cover
[2] Opening in rear panel for mounting on the wall
[3] Temperature/volume selector
[4] Gas adjustment
[5] Digital display
[6] Switch/LED - Low water pressure indicator
[7] LED - Burner status check
Dimensions
A
(mm)
GWH10...
310
GWH13...
350
GWH16...
425
Table 4
Dimensions
6
B
C
D
580
228
115
655
228
140
655
334
140
[8] Gas connection
[9] Connection collar for flue
[10] Draught diverter
[11] Copper Heat exchanger
[12] Burner
[13] Gas valve
[14] Ignition unit
E
F
G
463
60
25
510
95
30
540
65
30
H (Ø)
Natural gas
LP gas
20
15
20
15
20
15
6 720 608 992 (2018/01)