22 | KTS 350 (KTS 3a Series) | Operation
5.8

On-screen keyboard

The KTS 350 features a virtual keypad. Pressing the
icon in the task bar or pressing the function key ƒ for
> 2 seconds opens or closes the on-screen keyboard as
applicable.
The on-screen keyboard functions in the same way as
a conventional keyboard. The following setting options
are available:
If calling up a function on a standard keyboard would
involve pressing two keys simultaneously (e.g. <Alt> +
<F4>), these keys are to be pressed consecutively on
the on-screen keyboard. The special keys <Shift>, <Alt>
and <Ctrl> must always be pressed first.
!
On account of software programming differences, it
cannot be guaranteed that the on-screen keyboard
keypad will work with every type of software.
5.9

System settings

The power plan settings and the screen brightness can
be altered under "Start >> Control panel >> Power
options" or by pressing and holding the
the stylus.
5.9.1

Volume adjustment

By clicking on the
icon in the task bar with the stylus,
the volume of the KTS 350 can be adjusted.
5.9.2

Calibrating touch screen

The purpose of the "eGalaxTouch" application is to
calibrate the touch screen in the respective view
(horizontal or vertical).
1. Start "eGalaxTouch" with a double click on the touch
screen.
2. Under the Tools tab, select <Linearization> (9-point
linearization) or <4-point calibration>.
i
Bosch recommends the 9-point linearization in order
to achieve sufficiently accurate calibration of the
touch screen.
3. Touch calibration or linear points with the stylus and
hold until the OK symbol appears.
i
To avoid errors, the line of vision must be vertically
above the calibration point. Click onto the
calibration point as accurately as possible.
4. On completion of calibration, end the application
with <OK>.
"
This completes the calibration.
|
1 689 989 293
2018-03-24
5.10

Print

A printer (e.g. PDR 377) can be connected by way of
the USB interface of the KTS 350.
i
For details of printer drivers and installation see the
printer manufacturer's information
i
Information on printing can be found in the online
help for the Bosch applications.
5.11

Troubleshooting

Fault
The KTS 350 cannot be
switched on and the
display remains blank.
KTS 350 does not
react to any key
command.
icon with
After clicking onto
the touch screen with
the stylus, the mouse
pointer does not appear
at the same location
Operation by way
of stylus and touch
screen is no longer
possible.
Note
The capacity of the internal storage
battery is not sufficient to start the
KTS 350.
Connect the external power supply
unit.
1. Press and hold the ON button for
5 seconds.
2. Switch on the KTS 350 again.
This switch-off procedure is only to
be employed if the KTS 350 will not
react to any key being pressed. This
may result in loss of data on the hard
disk if it is implemented during regular
operation. Data created in the course of
this diagnostic application may have to
be entered again.
Touch screen calibration must be
performed.
Under "START >> Programs
>> eGalaxTouch", select the
"eGalaxTouch" menu, see sec. 5.9.2
Touch screen calibration must be
performed. Connect the mouse or
keyboard.
In the start bar under "START
>> Control panel", select the
"eGalaxTouch", see sec. 5.9.2