hit counter script

Technical Data - Siemens VersiCharge AC 8EM1312-4AF10-0AA3 Installation And Operation Manual

Electric vehicle charging station
Table of Contents

Advertisement

VersiCharge AC Series – Technical data
Features and functions
Charging mode
Vehicle connection
AC power output
Mounting options
Touch Button
Charging status LEDs
Communication status LEDs
Load management
Communication
a
Interfaces
User authentification
Configuration
Back-end protocol
Software upgrade
Electrical design
Power supply voltage
Rated current settings (A)
Cross wire section
Network type
Energy metering
a
Ground fault protection
DC residual current monitoring
Over voltage protection
Over current protection
Operating altitude
General design
Environmental rating
Dimensions (HxWxD)
Weight
Ambient conditions
Colors
Certificates and standards
cUL listed
EMC
a Only applicable for 8EM1312-4CF18-0FA3 and 8EM1312-5CF18-0FA3.
Max.
current
40 A
Basic
48 A
Single-family
versions
40 A
High End
48 A
40 A
Child
48 A
Multi-family
versions
40 A
Parent
48 A
Level 2
J1772 plug with 20 ft cable, 40/48 A / integrated cable management
Single phase up to 9.6 kW (40 A) or 11.5 kW (48 A)
Wall and post mounting, see accessories
Time delay, return to max, power level, reset ground fault
Power, Cold start, time delay, charging state, reduced power level, authentication
Connected / not connected during operation, signal strength during commissioning
via OCPP
Ethernet and Wi-Fi
Ready for plug-and-charge acc. to ISO 15118 (upgradeable OTA)
via Siemens mobile app
OCPP 1.6, upgrade-able to OCPP 2.0
over the air (OTA)
Single phase: 208 V / 240 V AC, 60 Hz
12, 16, 24, 32, 40, 48
Single phase: 8 Awg / 6 Awg (75C rated wire)
Single phase / split phase
revenue accurate, ANSI C12.20 compliant metering
20 mA
Not applicable
Under voltage: 167 V (min. 80 V) / over voltage: 267 V (max. 275 V)
Current +10% above configured threshold, min. +2A, 5 seconds
9,840 ft
Indoor and Outdoor, NEMA 4, IK 10
16.10 x 7.09 x 3.78 (in)
17 lbs
Operating temperature: -31°F - +122°F, Storage Temp.: -40°F to +140°F, 98% non-condensing
Silver Metallic (Pantone 10077), Black holster
according to UL 1998, UL 991, UL2594/CSA C22.2 No.280/NMX-J-677-ANCE, UL 2231-1/CSA C22.2 No.281.1/
NMX-J-668-1, UL 2231-2/CSA C22.2 No.281.2/NMX-J-668/2-ANCE, UL 2251/CSA C22.2
No.282/NMX-J-678-ANCE
FCC Part 15.247, FCC Part 15B, FCC Part 15C
Model number
HW ready for
ISO 15118
8EM1312-4AF10-0AA3
8EM1312-5AF10-0AA3
8EM1312-4CF18-0FA3
8EM1312-5CF18-0FA3
8EM1310-4CF14-0GA0
8EM1310-5CF14-0GA0
8EM1310-4CF14-1GA1
8EM1310-5CF14-1GA1
Installation and Operations Manual
Wi-Fi and
Modbus
RFID
Ethernet
RTU / TCP
identifica-
tion
| VersiCharge™ AC
Revenue grade
LTE
metering
WCDMA
33