Wall mounted gas condensing boiler

Advertisement

Operating Instructions
Wall mounted gas condensing boilers
Condens 5000W
ZBR 70-3 | ZBR 100-3

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Condens 5000W

  • Page 1 Operating Instructions Wall mounted gas condensing boilers Condens 5000W ZBR 70-3 | ZBR 100-3...
  • Page 2: Table Of Contents

    ▶ Read and retain the operating instructions (heat source, heating controller, etc.) prior to operation. ▶ Observe the safety instructions and warnings. Determined use The product may only be used for the heating of boiler water and for DHW heating. Condens 5000W – 6720813953 (2018/12)
  • Page 3 ▶ Use a CO detector, which gives an alarm in good – If devices with an air discharge to the outside are time if CO escapes. subsequently installed (e.g. extractor fans, kitchen fans or air conditioning units). Condens 5000W – 6720813953 (2018/12)
  • Page 4: Product Information

    • Condens 5000W ZBR 70-3 • Condens 5000W ZBR 100-3 The designation of the wall mounted condensing boiler comprises the following: • Bosch: manufacturer • Condens 5000W ZBR-3: product name • 70 or 100: type name 0010020118-001 Fig. 2 Opening the gas tap...
  • Page 5: Opening Service Valves

    ON for central heating user interface. ON for DHW Pump ON Outside temperature display An interlocking fault has occurred or the wall mounted gas condensing boiler requires a service. Table 2 Readings on the display Condens 5000W – 6720813953 (2018/12)
  • Page 6: Information Menu

    Only displayed with weather-compensated 30 % - max. (setting max. parameter). control. ▶ Increase the minimum pump speed if parts of the heating system do not Calculated boiler temperature (setpoint) [ °C] become hot enough. during heating mode Condens 5000W – 6720813953 (2018/12)
  • Page 7: Anti-Freeze Protection

    ▶ Put ON/OFF switch at the user interface to position “0”. condensing boiler is in ▶ Close the gas isolator under the wall mounted gas condensing boiler. standby mode, there is ▶ Drain the entire heating system. no heat demand. Condens 5000W – 6720813953 (2018/12)
  • Page 8 • Check whether a wall mounted gas sufficient number of 2 2 0 condensing boiler radiator valves are open. captured a different • Bleed radiators and vent temperature. heating system. • Reset the wall mounted gas condensing boiler. Condens 5000W – 6720813953 (2018/12)
  • Page 9: A Fault Has Occurred But No Fault Code Is Displayed

    The various assemblies can be easily dismantled. Synthetic materials are marked accordingly. Assemblies can therefore be sorted by composition and passed on for recycling or disposal. 0010020122-001 Fig. 7 Right-hand side of the wall mounted gas condensing boiler Serial number Device type Condens 5000W – 6720813953 (2018/12)
  • Page 12 Robert Bosch (Australia) Pty Ltd Thermotechnology Division 1555 Centre Road Clayton Victoria 3168 Australia Phone: 1300 30 70 37 Fax: 1300 30 70 38 www.bosch-climate.com.au New Zealand Phone: 0800 54 33 52 Fax: 0800 54 33 55 www.bosch-climate.co.nz...